Panasonic CU-KS18NKU user manual

User manual for the device Panasonic CU-KS18NKU

Device: Panasonic CU-KS18NKU
Category: Air Conditioner
Manufacturer: Panasonic
Size: 2.59 MB
Added : 4/16/2014
Number of pages: 122
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Panasonic CU-KS18NKU. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Panasonic CU-KS18NKU.

For your convenience

If looking through the Panasonic CU-KS18NKU user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Panasonic CU-KS18NKU on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Panasonic CU-KS18NKU to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Panasonic CU-KS18NKU User manual - Online PDF
Advertisement
« Page 1 of 122 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Panasonic CU-KS18NKU but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Panasonic CU-KS18NKU. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TECHNICAL & SERVICE MANUAL
CS-KS18NKU + CU-KS18NKU
+ CU-KS18NKUA
CS-KS24NKU + CU-KS24NKU
+ CU-KS24NKUA
DC INVERTER SPLIT SYSTEM AIR CONDITIONER
Indoor Model No. Product Code No. Outdoor Model No. Product Code No.
CS-KS18NKU 1 852 360 90 CU-KS18NKU 1 852 361 18
CS-KS24NKU 1 852 360 91 CU-KS18NKUA 1 852 361 19
CU-KS24NKU 1 852 361 21
CU-KS24NKUA 1 852 361 22
Indoor Unit Outdoor Unit
CS-KS18NKU
CS-KS24NKU
CU-KS18NKU
CU-KS18NKUA
IMPORTANT
These air conditioners employ new
refrigerant R410A.
Pay spec

Summary of the content on the page No. 2

SAFETY PRECAUTIONS • Before doing repair work, please read the " SAFETY PRECAUTIONS" carefully and fully understand them. • The precautionary items here are divided into " Warning" and " Caution" items. Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly, are included in the " Warning" table. However, even precautionary items identified as " Caution" also have the potential for serious consequences if

Summary of the content on the page No. 3

Warning If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite. Prohibit If refrigerant gas leaks during the work, ventilate the room. If refrigerant gas catches fire, harmful gas may be generated. Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle. If air or other contaminants mix with the gas, pressure will become extremely high in the refrigerating cycle, which may cause a unit breakdown." Prohibit When th

Summary of the content on the page No. 4

Table of Contents Page 1. OPERATING RANGE ................................................................................................................... 6 2. SPECIFICATIONS 2-1. Unit Specifications ............................................................................................................. 7 2-2. Major Component Specifications ....................................................................................... 15 2-3. Other Component Specifications ..................

Summary of the content on the page No. 5

Page 11. REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN SERVICING UNIT 11-1. Characteristics of New Refrigerant R410A ......................................................................... 59 11-2. Checklist before Servicing ................................................................................................... 60 11-3. Tools Specifically for R410A ................................................................................................ 61 11-4. Tubing Installation Procedures

Summary of the content on the page No. 6

1. OPERATING RANGE Models: CS-KS18NKU + CU-KS18NKU CS-KS24NKU + CU-KS24NKU Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 °F DB / 71 °F WB 115 °F DB Cooling Minimum 67 °F DB / 57 °F WB 67 °F DB Models: CS-KS18NKU + CU-KS18NKUA CS-KS24NKU + CU-KS24NKUA Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 °F DB / 71 °F WB 115 °F DB Cooling Minimum 67 °F DB / 57 °F WB 0 °F DB 6

Summary of the content on the page No. 7

2. SPECIFICATIONS 2-1. Unit Specifications Indoor Unit CS-KS18NKU Outdoor Unit CU-KS18NKU < 230V > Voltage Rating 230V Single-Phase 60Hz Cooling Total Capacity BTU/h 17,500 ( 4,000 to 17,500 ) kW 5.15 ( 1.2 to 5.15 ) Sensible Capacity 13,100 BTU/h Latent Capacity BTU/h 4,400 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 524 (890) / 441 (749) / 377 (641) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 253 Running Amperes A 7.0 ( 1.2 to 7.0 ) Power Input W 1,500 ( 250 to 1

Summary of the content on the page No. 8

Indoor Unit CS-KS18NKU Outdoor Unit CU-KS18NKU < 208V > Voltage Rating 208V Single-Phase 60Hz Cooling Total Capacity BTU/h 17,500 ( 4,000 to 17,500 ) kW 5.15 ( 1.2 to 5.15 ) Sensible Capacity 13,100 BTU/h Latent Capacity BTU/h 4,400 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 524 (890) / 441 (749) / 377 (641) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 253 Running Amperes A 7.7 ( 1.2 to 7.7 ) Power Input W 1,500 ( 250 to 1,500 ) Power Factor % 94 EER BTU/h/W 11.7 SEE

Summary of the content on the page No. 9

Indoor Unit CS-KS24NKU Outdoor Unit CU-KS24NKU < 230V > Voltage Rating 230V Single-Phase 60Hz Cooling Total Capacity BTU/h 24,200 ( 4,000 to 24,200 ) kW 7.1 ( 1.2 to 7.1 ) Sensible Capacity 14,800 BTU/h Latent Capacity BTU/h 9,400 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 659 (1,120) / 571 (970) / 494 (839) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 253 Running Amperes A 10.8 ( 1.3 to 10.8 ) Power Input W 2,460 ( 280 to 2,460 ) Power Factor % 99 EER BTU/h/W 9.8 SE

Summary of the content on the page No. 10

Indoor Unit CS-KS24NKU Outdoor Unit CU-KS24NKU < 208V > Voltage Rating 208V Single-Phase 60Hz Cooling Total Capacity BTU/h 24,200 ( 4,000 to 24,200 ) kW 7.1 ( 1.2 to 7.1 ) Sensible Capacity 14,800 BTU/h Latent Capacity BTU/h 9,400 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 659 (1,120) / 571 (970) / 494 (839) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 253 Running Amperes A 12.1( 1.3 to 12.1 ) Power Input W 2,460 ( 280 to 2,460 ) Power Factor % 98 EER BTU/h/W 9.8 SEE

Summary of the content on the page No. 11

Indoor Unit CS-KS18NKU Outdoor Unit CU-KS18NKUA < 230V > Voltage Rating 230V Single-Phase 60Hz Cooling Total Capacity BTU/h 17,500 ( 4,000 to 17,500 ) kW 5.15 ( 1.2 to 5.15 ) Sensible Capacity 13,100 BTU/h Latent Capacity BTU/h 4,400 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 524 (890) / 441 (749) / 377 (641) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 253 Running Amperes A 7.0 ( 1.2 to 7.0 ) Power Input W 1,500 ( 250 to 1,500 ) Power Factor % 93 EER BTU/h/W 11.7 SE

Summary of the content on the page No. 12

Indoor Unit CS-KS18NKU Outdoor Unit CU-KS18NKUA < 208V > Voltage Rating 208V Single-Phase 60Hz Cooling Total Capacity BTU/h 17,500 ( 4,000 to 17,500 ) kW 5.15 ( 1.2 to 5.15 ) Sensible Capacity 13,100 BTU/h Latent Capacity BTU/h 4,400 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 524 (890) / 441 (749) / 377 (641) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 253 Running Amperes A 7.7 ( 1.2 to 7.7 ) Power Input W 1,500 ( 250 to 1,500 ) Power Factor % 94 EER BTU/h/W 11.7 SE

Summary of the content on the page No. 13

Indoor Unit CS-KS24NKU Outdoor Unit CU-KS24NKUA < 230V > Voltage Rating 230V Single-Phase 60Hz Cooling Total Capacity BTU/h 24,200 ( 4,000 to 24,200 ) kW 7.1 ( 1.2 to 7.1 ) Sensible Capacity 14,800 BTU/h Latent Capacity BTU/h 9,400 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 659 (1,120) / 571 (970) / 494 (839) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 253 Running Amperes A 10.8 ( 1.3 to 10.8 ) Power Input W 2,460 ( 280 to 2,460 ) Power Factor % 99 EER BTU/h/W 9.8 S

Summary of the content on the page No. 14

Indoor Unit CS-KS24NKU Outdoor Unit CU-KS24NKUA < 208V > Voltage Rating 208V Single-Phase 60Hz Cooling Total Capacity BTU/h 24,200 ( 4,000 to 24,200 ) kW 7.1 ( 1.2 to 7.1 ) Sensible Capacity 14,800 BTU/h Latent Capacity BTU/h 9,400 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 659 (1,120) / 571 (970) / 494 (839) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 253 Running Amperes A 12.1( 1.3 to 12.1 ) Power Input W 2,460 ( 280 to 2,460 ) Power Factor % 98 EER BTU/h/W 9.8 SE

Summary of the content on the page No. 15

2-2. Major Component Specifications 2-2-1. Indoor Unit Indoor Unit CS-KS18NKU Control PCB Part No. CB-CS-KS18NKU Controls Microprocessor Control Circuit Fuse 250V 3A Fan Type Cross-Flow Q'ty ... Dia. and Length inch (mm) 1 ... D3-5/8 / L33-9/32 (D92/L845) Fan Motor Type DC Motor Model ... Q'ty SIC-41CVJ-D847-3 ... 1 No. of Poles 8 Rough Measure RPM (Cool) 1,250 Nominal Output W 30 Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Internal Controller Over-Current Protecti

Summary of the content on the page No. 16

Indoor Unit CS-KS24NKU Control PCB Part No. CB-CS-KS24NKU Controls Microprocessor Control Circuit Fuse 250V 3A Fan Type Cross-Flow Q'ty ... Dia. and Length inch (mm) 1 ... D3-5/8 / L33-9/32 (D92/L845) Fan Motor Type DC Motor Model ... Q'ty SIC-41CVJ-D847-3 ... 1 No. of Poles 8 Rough Measure RPM (Cool) 1,500 Nominal Output W 30 Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Internal Controller Over-Current Protection Yes Over-Heat Protection Yes Run Capacitor Micro F -

Summary of the content on the page No. 17

2-2-2. Outdoor Unit Outdoor Unit CU-KS18NKU Control PCB Part No. CB-CU-KS18NKU Controls Microprocessor Control Circuit Fuse 250V 25A Compressor Type DC Twin Rotary (Hermetic) Compressor Model / Nominal Output C-6RVN93H0M / 1,050W Compressor Oil ... Amount Pints (cc) FV50S ... 0.74 (350) Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm U - V : 0.482 V - W : 0.482 W - U : 0.482 Safety Device CT (Peak current cut-off control) Yes Compressor Discharge Temp. Control Yes Operation cut-off cont

Summary of the content on the page No. 18

Outdoor Unit CU-KS24NKU Control PCB Part No. CB-CU-KS24NKU Controls Microprocessor Control Circuit Fuse 250V 25A Compressor Type DC Twin Rotary (Hermetic) Compressor Model / Nominal Output G8T265FU1JW / 2,410W Compressor Oil ... Amount Pints (cc) FV50S ... 1.49 (700) Coil Resistance (Ambient Temp. 77 °F (25 °C)) Ohm U - V : 0.36 V - W : 0.36 W - U : 0.36 Safety Device CT (Peak current cut-off control) Yes Compressor Discharge Temp. Control Yes Operation cut-off control in abnormal ambient

Summary of the content on the page No. 19

Outdoor Unit CU-KS18NKUA Control PCB Part No. CB-CU-KS18NKUA Controls Microprocessor Control Circuit Fuse 250V 25A Compressor Type DC Twin Rotary (Hermetic) Compressor Model / Nominal Output C-6RVN93H0M / 1,050W Compressor Oil ... Amount Pints (cc) FV50S ... 0.74 (350) Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm R - S : 0.482 S - T : 0.482 T - R : 0.482 Safety Device CT (Peak current cut-off control) Yes Compressor Discharge Temp. Control Yes Operation cut-off control in abnormal amb

Summary of the content on the page No. 20

Outdoor Unit CU-KS24NKUA Control PCB Part No. CB-CU-KS24NKUA Controls Microprocessor Control Circuit Fuse 250V 25A Compressor Type DC Twin Rotary (Hermetic) Compressor Model / Nominal Output G8T265FU1JW / 2,410W Compressor Oil ... Amount Pints (cc) FV50S ... 1.49 (700) Coil Resistance (Ambient Temp. 77 °F (25 °C)) Ohm U - V : 0.36 V - W : 0.36 W - U : 0.36 Safety Device CT (Peak current cut-off control) Yes Compressor Discharge Temp. Control Yes Operation cut-off control in abnormal ambien


Alternative user manuals
# User manual Category Download
1 Panasonic CS-1873KR User manual Air Conditioner 243
2 Panasonic CS-A12CKPG User manual Air Conditioner 72
3 Panasonic CS-A12CKP User manual Air Conditioner 98
4 Panasonic AC Robot 2006/2007 User manual Air Conditioner 45
5 Panasonic 2008 User manual Air Conditioner 83
6 Panasonic CS-A18CTP User manual Air Conditioner 28
7 Panasonic AW-PS505 User manual Air Conditioner 6
8 Panasonic CS-A12CTP User manual Air Conditioner 31
9 Panasonic CS-A24CTP User manual Air Conditioner 36
10 Panasonic CS-A24CKPG User manual Air Conditioner 4
11 Panasonic CS-A7CKP User manual Air Conditioner 207
12 Panasonic CS-A9CKP User manual Air Conditioner 45
13 Panasonic CS-A9CKPG User manual Air Conditioner 9
14 Panasonic CS-C12CKP User manual Air Conditioner 19
15 Panasonic CS-C24BKP User manual Air Conditioner 33
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21