Summary of the content on the page No. 1
f*
S.ave This Manual
For Future Reference
owner's
manual
MODEL NO.
758.144120
758.144240
Model No. 758.144240
Kenmope'"
QUIETCOMFORT"
EVAPORATIVE
CONSOLE
FOR YOUR
HUMIDIFIER
SAFETY:
READ ALL , Operating Instructions
INSTRUCTIONS
, Parts List
CAREFULLY
J
Sold by SEARS, ROEBUCK AND COo, Chicago, H 60684 U,S°Ao
Part No. SP5377 Pnnted in U.S.A.
Summary of the content on the page No. 2
FULL ONE YEAR WARRANTY ON HUMIDIFIER If, within one (1) year from the date of purchase, this humidifier fails due to defect in material or work- manship, we will repair it free of charge. If, within two (2) years from the date of purchase, the motor fails due to defect in material or workmanship, we will repair it free of charge. (Applies to Model 758.144140 and 758.144240 only). This warranty service is available by simply returning the humidifier to the nearest Sears Service Cen- ter/Departmen
Summary of the content on the page No. 3
Know Your Humidifier HINGES SPLASH GUARD ID STORED HERE CONTROL AREA MOTOR .E SUPPORT ACTUATOR WATER LEVEL INDICATOR HOUSING-FILTER FIGURE 1 MODEL NO. 758.144240 FLOAT Humidifier Operations Your new Sears humidifier is designed to satisfy home 758.14424O 758.144120 Description humidity requirements through the principle of evapora- tion of water into the air. 14 12 Gallon Output After water is added to the tank, the filters begin to soak 7 7 Tank Capacity up the water and become totally saturate
Summary of the content on the page No. 4
Humidifier Operations (continued) HUMIDIFIEOAIR DRYROOMAIR DRY ROOM AIR CAUTION: Keep your humidifier clean. While humidifiers do not cause colds, some studies sug- \to t N gest that dirty humidifiers can cause cold like symptoms in some people. To avoid this, we rec- ommend you clean your humidifier weekly with Humidifier Cleaner 32-7283 and use Bacteriostat 32-14900. These are available at your local Sears store. WATER Figure 2 Assembly Instruction Locate handle and using a screwdriver attach
Summary of the content on the page No. 5
4.Pushdownonclipuntilfullyseatedagainstlid hinge. (Seefig.6) 5.Repeat steps3and4to seatotherclip. NOTE: Yourlidisnowfastened tothehousing. Werec- ommend notto remove thelidretention clipsoncethey havebeensecured. 6•Toremove yourmotorsupportsection liftlidandliftout motorsupportsection,thenslidecordto the rightto remove fromhousing• Figure 5 Figure 6 Water Fill WARNING: 1. To avoid shock, always unplug humidifier before filling, cleaning, or servicing. LOUVERS _CONTROL 2. Do not pour or spill wat
Summary of the content on the page No. 6
Operating Humidifier Controls Humidity Control: This control adjusts the amount of humidity depending on HU_lorr y CONTROL HLIM[OfTY CONTROL user's needs. The humidifier will turn on and off as required to maintain level of humidity you select. (See Fig. 10) Medium setting is recommended but there are f, r_ ji ,,p. times when a low or high amount of humidity may be pre- ferred. For constant operation of humidifier. Constant On Kenmore rJ_ KenmoPe [] QUIETCOMFORT QUIE] COMFORT allows for the maxi
Summary of the content on the page No. 7
Cleaning of Humidifier Tank CAUTION: Local water purity varies from area to WARNING: To avoid toxic injury, fire or damage to area and under certain conditions water impurities humidifier, use only cleaners specially recom- and airborne bacteria may promote the growth of mended for humidifiers. Never use flammable, microorganisms in the reservoir of the humidifier. combustible or poisonous material to clean your humidifier. To avoid scalds and damage to humidi- To retard bacteria growth that may
Summary of the content on the page No. 8
Care of Humidifier Tank (continued) 2. Empty water reservoir after 20 minutes. Rinse with Bi-Weekly Maintenance water until bleach smell is gone. Dry with clean cloth or Removing Scale paper towel. 1. Partially fill the water reservoir with one 8oz. cup of End of Season Maintenance undiluted white vinegar. Let solution stay 20 minutes. 2. Clean all interior surfaces with soft brush. Dampen soft 1. Follow bi-weekly maintenance instructions at end of humidification season or when humidifier will n
Summary of the content on the page No. 9
Troubleshooting Model 758.144120 and 758.144240 Trouble Probable Cause Remedy 1. Unit will not run, • Switch Actuator not free to work properly. • Remove shipping rubber band or unhook ring. or will not shut off. 2. Water runs out of • Splash guard not in place or missing. • Hang splash guard on rear of unit, be sure lou- the rear of unit vers are covered. ° Too much water. ° Check Full label in tank. Do not overfill. • Switch actuator ring is not in place. 3. Unit will not dry • Connect switch
Summary of the content on the page No. 10
Repair Parts Parts List For Sears Humidifier Model 758.144120 and 758.144240 1 25 11 H GUARD 12 J J 18 13 17 16 10
Summary of the content on the page No. 11
Repair Parts Parts List for Sears Humidifier Model No. 758.144120 and 758.144240 Always order by Part Number--Not by Key Number Model No. Key Description No. 758.144120 758.144240 817241 817241 1 Fan Guard 29433 29433 2 Screw-Pan Hd. Ty. "AB" 8 x 5/8 819284 3 Label 82O546 817235-1 4 Knob 817235-1 817235 5 Knob 817235 819212 6 819212 • Control (Includes Key #4 & 5) 817878 Tie Wire 817878 817380 8 Switch Actuator 817380 817452-1 9 Lid 817186-1 819428 10 Lid Retention Clip 819428 817735 _il 817735
Summary of the content on the page No. 12
S_FA/RS owner's Kenmope'" manual QUIETCOMFORT" Conso Humidifier Service for your humidifier is available by returning itto the. SERVICE nearest Sears Service Center/Department threughout the United States. The model number will be found on the Humidifier identification MODEL NO. label. Always mention the Model Number when requesting ser- vice or repair parts. 758.144120 758.144240 HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOL- LOWING INFORMATION: 1. PART NUMBER: (See