Summary of the content on the page No. 1
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 1
CAUTION: READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
SAVE THIS OWNER’S MANUAL FOR FUTURE REFERENCE.
Model No.
HD14070
TM
HD14070
Evaporative Console
Humidifier Owner’s Manual
Part No. SP6647 12/09 Printed in U.S.A.
Summary of the content on the page No. 2
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 2 GENERAL SAFETY INSTRUCTIONS 4. Keep the humidifier clean. Safety Signal Words 5. Do not put foreign objects inside the DANGER: means if the safety information is humidifier. not followed someone will be seriously 6. Do not allow to be used as a toy. Close injured or killed. attention is necessary when used by or WARNING: means if the safety information near children. is not followed someone could be seriously 7. Never use your humidif
Summary of the content on the page No. 3
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 3 Know Your Humidifier Description HD14070 * Output/24 hrs 14 Gallons/53 Litres Capacity of Bottle 2-3/8 Gallons/9 Litres Sq. Ft. Coverage 2900 * Fan Speeds 3 Auto Fan Speed Yes Replacement Filter Set of 4 (HDC12) Refill Indicator Yes Auto Shut Off Yes Auto Humidistat Yes Controls Electronic (Push Button) Control Lock Yes Casters Yes (4) ETL Listed Yes Volts 120 A.C. Hertz 60 Amps 2.88 Watts 165 * Based on an area with average insulatio
Summary of the content on the page No. 4
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 4 How Your Humidifier Works Your new MoistAIR humidifier is designed to satisfy home humidity requirements through the principle of evaporation of water into the air. After water is added to the bottle, the filters begin to soak up the water and become totally saturated in approxi-mately 30 minutes. Air is drawn in from the rear of the humidifier and through the filters by means of circulation fans. As air passes through the filters, mo
Summary of the content on the page No. 5
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 5 Location Instructions Moist air (humidity) produced will disperse into the WARNING: For your own safety, do not use whole house, but area closest to the unit will have humidifier if any parts are damaged or the highest humidity. If the unit is positioned close missing. to a window, condensation may form on the window pane. If this is not appropriate the unit Step 1: should be repositioned in another location. Place humidifier on a fla
Summary of the content on the page No. 6
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 6 Electrical Hook-Up If the plug does not fit fully in the outlet, reverse Locate nearest 120V A.C. wall socket in the plug. If it still does not fit, contact a qualified location desired, preferably on inside wall. With electrician to install the proper outlet. Do not the humidifier in the desired location, route the change the plug in any way. electrical cord safely so no one will trip or upset the humidifier. Plug in the electrical c
Summary of the content on the page No. 7
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 7 Water Fill (continued) Each water bottle is designed with a “Side-Fill Cap” that is easily removable. Remove the “Side- Fill Cap” on the side of the water bottle by twisting counterclockwise. Place the opening of the water bottle under a water faucet (the bottle should fit under a four-inch clearance faucet). Fill with recommended mixture of cold water and Bacteriostat (if necessary) only. Solid debris could make the valve leak. Insta
Summary of the content on the page No. 8
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 8 Operating the Controls Where you set your desired humidity levels depends on your personal comfort level, outside temperature and inside temperature. A starting set point of 30% - 40% ROOM humidity is recommended but there may be conditions that require a different setting. IMPORTANT: Water damage may result if condensation starts to form on windows or walls. Humidity SET point should be lowered until condensation no longer forms. We
Summary of the content on the page No. 9
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 9 Operating the Controls (continued) The SET readout has a range of 25% to 65% and is adjusted in increments of 5%. Initially depressing the humidity button will display the current humidity setting. Each additional press of the button increases the setting by 5%. A SET point of 65% operates the humidifier continuously regardless of the ROOM reading. The humidistat that senses the readings is located on the power cord. Insure that this
Summary of the content on the page No. 10
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 10 Using Your Humidifier (continued) Check Filter Indicator Humidistat The humidistat located on the power cord senses The ability of any humidifier to efficiently supply the percentage of humidity in the air. It causes the humidity output relies heavily on the condition of the humidifier to cycle on and off to maintain the filter. As the filter loads with impurities it gradually selected humidity SET point. The fan will turn on if lose
Summary of the content on the page No. 11
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 11 Replacement and Care of Filters WARNING: To reduce the risk of shock or injury from moving parts, always unplug humidifier before removing or replacing any parts. CAUTION: To help retard bacteria growth and keep maximum efficiency, the filter should be replaced at least once per season, or more often under hard water conditions. Use MoistAIR HDC12 recommended replacement filter. The filters may be rinsed periodically in clear water o
Summary of the content on the page No. 12
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 12 Replacement and Care of Filters (con’t) e. Replace the filter housing in the cabinet. NOTE: There is a front and back orientation. To position the filter housings correctly: • Be sure that the spring tabs of filter housings are towards front of cabinet. • Align the lower portion of the filter assembly over the six ribs located at the bottom rear of the humidifier cabinet. f. Position fan assembly onto the cabinet. Make sure the fan
Summary of the content on the page No. 13
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 13 Cleaning and Maintenance (cont’d.) Bi-Weekly Maintenance WARNING: To reduce the risk of shock, always unplug humidifier before cleaning or servicing. If Removing Scale humidifier is not unplugged, fan could start after 1. Fill the reservoir with water and add one 8 housing is removed. oz. (236 ml) cup of undiluted white vinegar. Let solution stay for 20 minutes. Step 2: 2. Clean all interior surfaces with soft brush. To Remove Parts
Summary of the content on the page No. 14
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 14 Troubleshooting Trouble Probable Cause Remedy Digital display not illuminated. • No Power. • Check 120 volt power source. • Power button has not been depressed. • Press power button once to turn on. Fan not operating (digital • ROOM humidity level is not 3% or more • Raise SET humidity level if desired. display is illuminated). below SET humidity level. • Increase fan speed. • Reservoir is empty. • Fill humidifier with water. Fan run
Summary of the content on the page No. 15
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 15 Repair Parts ® MD Parts List for MoistAIR Humidifier Model No. HD14070 15
Summary of the content on the page No. 16
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 16 Repair Parts ® MD Parts List for MoistAIR Humidifier Model No. HD14070 Always order by part number - Not by key number Key No Part No. Description 1 828741-2 Lid, Stationary 2 828855-2 Lid, Pivoting 3 831680-1 Control Assembly 4 824690 “Side-Fill Cap” 5 828192 Bottle, Left (Includes Key Nos. 4 & 7) 6 828726 Bottle, Right (Includes Key Nos. 4 & 7) 7 509229-1 Cap, Valve Assembly 8 828199-10 Cabinet 9 823726 Rail, Kick 10 STD601107 Scr
Summary of the content on the page No. 17
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 17 Warranty ® Moist AIR PRODUCTS HUMIDIFIER WARRANTY POLICY EFFECTIVE APRIL 1, 2008 SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS. This product is warranted against defects in workmanship and materials for one year from the date of sale except for motors, which are warranted for two years. This warranty does not apply to filters or wicks which are customer replaceable parts. This warranty applies only to the origi
Summary of the content on the page No. 18
QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 18 FOR TECHNICAL HELP, CALL (800) 547-3888 FROM USA OR (888) 744-4687 FROM CANADA (Please have complete model number) ® MD Essick Air Products ® MD For more information about MoistAIR humidifiers, visit our website at www.moistair.com c 2009 Part No. SP6647 Form No. SP6647-1 Printed in U.S.A 12/09