Summary of the content on the page No. 1
HE225A,B and HE265A,B
Bypass Flow-Through
Humidifier
whole-house air quality system
PRODUCT DATA
FEATURES/BENEFITS
• Antimicrobial coating on pad prevents the surface
growth and migration of bacteria, mold, fungus and
algae on the humidifier pad.
• Bold new look with blue and white styling.
• Proven technology used for high performance
humidification and enhanced comfort.
• Preassembled for quicker installation.
• Small footprint, light weight and reversible
components allow easy mounting on eit
Summary of the content on the page No. 2
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER Humidifier Pad Dimensions: SPECIFICATIONS See Table 2. Capacity: Plenum Opening Dimensions (Height x Width): At 120°F (49°C) plenum temperature and 0.20 static See Table 3. pressure drop across supply and return: HE225A,B: 12 gallons per day (gpd) or 46 liters per Summer Shut-off Damper Dimensions (Height x Width): day (lpd). See Table 4. HE265A,B: 17 gallons per day (gpd) or 65 liters per day (lpd). Bypass Duct Opening (Diameter): 6 in. (152
Summary of the content on the page No. 3
15-5/16 (390) 12-7/16 (316) 12 (305) 13-9/16 (345) 11-7/16 (290) 12 (305) HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER Standard: Air Conditioning and Refrigeration Institute Tested: Standard 610. Models: HE225A TRADELINE® and HE265A TRADELINE® Bypass Flow-through Humidifier package includes humidifier pad, mounting template, self-piercing saddle valve, 24 Vac transformer, H8908B Convertible Humidity Control. HE225B TRADELINE® and HE265B TRADELINE® Bypass Flow-through Humidifier package i
Summary of the content on the page No. 4
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER 11. Reinstall the humidifier pad assembly in the humidifier housing. NOTE: Be sure the water feed tube is not pinched or kinked. 12. Hinge the cover in place and secure with the thumbscrew located at the bottom of the cover. WATER FEED NOZZLE HUMIDIFIER PAD ASSEMBLY FRAME M12248C COVER SIDEWALL Fig. 3. Typical humidifier installation locations. IMPORTANT Mount the humidifier at least 3 in. (76 mm) above the furnace jacket to allow adequate sp
Summary of the content on the page No. 5
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER PLUMBING THE SADDLE VALVE OPERATING THE HUMIDIFIER Hot or cold water, either hard or softened, can be used in the The HE225A and HE265A humidifier. Humidifiers are controlled by the Convertible Humidity 1. Use the self-piercing saddle valve (included) to tap into Control that is installed either the water supply line at an appropriate location. on an interior wall in the living area or on the return air duct. IMPORTANT Choose the humidity cont
Summary of the content on the page No. 6
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER Table 5. Recommended Convertible Humidity Control Settings. At Outside Temperature Recommended Setting At Outside Temperature Recommended Setting -20°F (-29°C) 15 +10°F (-12°C) 30 -10°F (-23°C) 20 +20°F (-7°C) 35 0°F (-18°C) 25 Above 20°F (-7°C) 40 Table 6. Recommended Frost Factor Settings. Humidity Level Recommended Adjustment Insufficient humidity Increase the frost factor dial by one setting. Condensation on windows Decrease the frost fact
Summary of the content on the page No. 7
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER 8. Check the humidifier pad and if excessive mineral IMPORTANT deposits are present, replace with a new antimicrobial Be sure the humidifier power is off. pad. 9. Disconnect the tube from the drain fitting on the bottom Beginning of Humidification Season of the humidifier housing. Refer to the Checkout Procedure section to complete the 10. Clean the drain fitting, if necessary. humidifier startup. 11. Bend the drain tube to loosen any mineral
Summary of the content on the page No. 8
40 30 50 20 60 10 OFF ON HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER REPLACEMENT PARTS Refer to Fig. 6 and Table 8 when ordering replacement parts. 10 4 9 8 11 5 6 12 3 13 7 8 1 8 2 M14820 Fig. 6. Exploded view of humidifier parts. 68-0244 8
Summary of the content on the page No. 9
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER Table 8. List Of Replacement Parts For HE220A,B, HE260A,B Humidifiers. Exploded View Number Description HE225 Part Number HE265 Part Number 1 Side wall 32001612-002 32001626-002 2 Bypass side wall 32001613-002 32001627-002 3 Cover Assembly 32001611-003 32001611-004 4 PerfectFlo™ water distribution tray 32001619-001 32001630-001 5 Antimicrobial humidifier pad HC22E1003 HC26E1004 6 Frame 32001621-001 32001632-001 7 Drain fitting 32001615-001 320
Summary of the content on the page No. 10
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER 68-0244 10
Summary of the content on the page No. 11
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER 68-0244 11
Summary of the content on the page No. 12
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER IMPROVE YOUR INDOOR AIR WITH A COMPLETE whole-house air quality system ULTRAVIOLET AIR TREATMENT SYSTEM • ZAP airborne germs. • Kill most germs before they recycle through your home. • Prevent mold spores from growing on your system cooling coils. F300E ELECTRONIC AIR CLEANER • TRAP airborne particles. • Up to 99% efficient at capturing airborne particles. • Effectively REDUCES fungi, bacteria, mold antigen, cat antigen and ragweed pollen ant