Bryant HUM-56-1 user manual

User manual for the device Bryant HUM-56-1

Device: Bryant HUM-56-1
Category: Humidifier
Manufacturer: Bryant
Size: 0.18 MB
Added : 7/14/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant HUM-56-1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant HUM-56-1.

For your convenience

If looking through the Bryant HUM-56-1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant HUM-56-1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant HUM-56-1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant HUM-56-1 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant HUM-56-1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant HUM-56-1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

installation and
HUM
start-up instructions
HUMIDIFIERS AND
HUMIDISTAT
Cancels: II 912D-56-3 II HUM-56-1
7-98
MODEL HUMBBLFP1025-A--
FAN-POWERED
HUMIDIFIER
MODEL HUMBBSFP1016-A--
FAN-POWERED
MODEL HUMBBLBP2018-A--
HUMIDIFIER
BYPASS HUMIDIFIER
MODEL HUMBBWTR2019-A-- MODEL HUMBBSBP2017-A--
WATER-SAVER
BYPASS HUMIDIFIER
A98361
→ Humidifiers
NOTE: Read the entire instruction in manual applicable to
WARNING: Before installing or servicing system, al-
specific unit before starting the installati

Summary of the content on the page No. 2

→I. INSPECT PACKAGE AND CHECK EQUIPMENT Inspect contents of packaged humidifier. File claim with shipping company prior to installation if shipment is damaged or incom- plete. The package should contain: TEMPLATE 1. Humidifier and media assembly PLENUM 2. Humidistat LEVEL 3. Template 4. Owner’s Manual 5. Warranty Certificate 6. Solenoid valve with bridge rectifier 7. Saddle valve assembly with adapter A97096 8. Four sheet metal screws Fig. 2—Preparing Plenum Opening 9. Foam tape IMPORTANT: For

Summary of the content on the page No. 3

IX. START-UP HUMIDIFIER HUMIDISTAT BROWN 24VAC 1. Open saddle valve to permit water flow to the solenoid. BROWN FURNACE 2. Check all connections for water leaks. 3. Set thermostat to call for heat. Set humidistat for highest humidity setting making sure contacts are closed. After a few minutes of operation, check the drain connection for leaks and to see if water is flowing through humidifier. TRANSFORMER (FIELD SUPPLIED) HUMIDIFIER HUMIDISTAT 4. Reversethermostatandhumidistatsettingstoinsurep

Summary of the content on the page No. 4

HUMIDIFIER HUMIDISTAT RED RED 24VAC BLU FURNACE "N" COIL BLUE 115V FIELD WIRING FAN TYPE UNITS ONLY TRANSFORMER (FIELD SUPPLIED) HUMIDIFIER HUMIDISTAT RED 115V 24V FIELD BLU WIRING 115V FIELD WIRING VERTICAL HORIZONTAL FAN TYPE UNITS ONLY A98366 A96010 → Fig. 5—Installation of HUMBBLFP1025-A-- Fig. 6—Installation of Humidistat Fan-Type Humidifier on Fan-Type Humidifier 2. Run 1/4-in. diameter (water line grade) tubing from saddle II. SELECT LOCATION (SEE FIG. 5.) valvetoadapteronsolenoidva

Summary of the content on the page No. 5

INSTALLATION OF HUMBBSFP1016-A-- 3. Rotate lower mounting base 180 degrees, so side access FAN POWERED HUMIDIFIER door is now on left. Bryant’s HUMBBSFP1016-A-- fan powered humidifier can only 4. Snap together top assembly to mounting base and reinstall beinstalledonthesupplyplenumofaforced-airsystem.Thisunit screws. requires an external 115-vac (fused) plug-in receptacle near the 5. Replacemediapadassembly(withdistributorreservoirup) equipment for proper operation. and side access door. It is r

Summary of the content on the page No. 6

SOLENOID TUBING VALVE ENCLOSURE INLET HOLE INLET HOLE SEAT HOUSING SOLENOID ENCLOSURE VALVE FLUSH AGAINST INLET POSITION TUBING INSIDE INLET HOLE (CUT LENGTH A97107 IF REQUIRED) Fig. 10—Top Mounting of Water Solenoid Valve IV. MOUNT THE HUMIDIFIER 1. Attach foam tape to back of mounting flange (exclude the off-set edge). 2. Hook off-set edge over opening cut in plenum. 3. Place humidifier in plenum aligning screw holes with A97099 flange. Fig. 11—Alternate Mounting of Solenoid

Summary of the content on the page No. 7

INSTALLATION OF HUMBBSBP2017-A-- BYPASS UNITS BYPASS HUMIDIFIER Bryant’sHUMBBSBP2017-A--bypasshumidifiercanbeinstalled on either the supply or return plenum of a forced air system. This unit requires an external bypass duct between the supply- and "N" COIL return-air ductwork. It is recommended to install the humidifier where it can be easily serviced. If this humidifier is installed with a central cooling ACCESS systemthebypassductmusthaveashutoffdampertocloseduring DOOR the cooling season. Al

Summary of the content on the page No. 8

5. Attach transfer tube to solenoid valve and insert free end NOTE: Wiring must comply with National Electrical Code and into inlet fitting on top of unit housing. any local codes or ordinances that may apply. 6. Attach bridge rectifier to solenoid valve. IX. START-UP 7. Insert sheet metal screws into lower holes in plenum, 1. Open saddle valve to permit water flow to the solenoid. pre-drilled using template. 2. Check all connections for water leaks. 8. Tightenscrewsuntilheadsprotrudeapproximate

Summary of the content on the page No. 9

II. SELECT LOCATION (SEE FIG. 14.) 8. Re-install media assembly. Ensure that square shaft of media assembly is located inside mating opening of motor BYPASS UNITS coupling. Ensure that bearing washer is located on interior side of bearing retainer. (See Fig. 15.) →V. INSTALL BYPASS DUCT Attach field-supplied 6-in. diameter duct, elbow, or starting collar withfield-supplied1/4-in.zipscrews.Installsupplied6-in.damper in 6-in. duct connector. "N" COIL IMPORTANT: On systems with central cooling, the

Summary of the content on the page No. 10

GASKET FLOAT PIN ARM RETAINER BEARING 1 VALVE BODY ⁄2 IN. LONG SCREW VALVE SEAT WASHER 1 ⁄4 IN. BLUNT SUPPORT POINT SCREW BRACKET (LEFT HAND INSTALLATION SHOWN) FLOAT VALVE ASSEMBLY REINSTALLING MEDIA ASSEMBLY A98370 → Fig. 15—Valve and Media Assembly for HUMBBWTR2019-A-- VIII. INSTALL HUMIDISTAT AND COMPLETE WIRING b. If installed during heating season, set unit for normal operation. 1. Mount humidistat on inside wall or return-air duct in accordance with section INSTALLATION OF HUMIDIS- TA

Summary of the content on the page No. 11

2. Remove protective backing from template furnished with MOUNTING HOLES eachcontrolandapplyself-adhesivesideonreturnairduct atselectedlocation.Followinginstructionsontemplateand in Fig. 21, drill 2 mounting holes and six 1/4-in. diameter sensing holes in duct. Sensing holes allow return air to reach nylon sensing element and operate humidistat. NOTE: Ifdesired,cutsquareholeinductasindicatedontemplate as an alternative to holes. 3. Removeprotectivebackingfromfoamgasketprovidedwith control and ap

Summary of the content on the page No. 12

MAKE OPENING IN DUCT MOUNT HUMIDISTAT CASE MOUNTING TEMPLATE FOAM GASKET CASE DRILL SIX 1/4 IN. DIAMETER HOLES ALTERNATE PROCEDURE: MOUNTING SCREWS (2) A97105 Fig. 21—Humidistat Installation Schematic RECOMMENDED HUMIDISTAT SETTING V. OPERATION OUTSIDE RECOMMENDED Whenrelativehumidityfallstohumidistatsetpoint,thehumidistat TEMPERATURES HUMIDISTAT SETTING switch makes contact and starts humidifier. In some central unit -20°F 15% humidifier systems, furnace fan must be operating before humidi-


Alternative user manuals
# User manual Category Download
1 Bryant 913B User manual Humidifier 0
2 Bryant HUMBBLBP2018-A User manual Humidifier 1
3 Bryant 913C User manual Humidifier 0
4 Bryant 914A User manual Humidifier 0
5 Bryant 905D User manual Humidifier 0
6 Bryant HUMBBLFP1025 User manual Humidifier 0
7 Bryant HUMBBLBP2018 User manual Humidifier 0
8 Bryant 912E User manual Humidifier 0
9 Bryant HUMBBLFP1025-A User manual Humidifier 1
10 Bryant HUMBBSBP2017 User manual Humidifier 0
11 Bryant HUMBBSFP1016 User manual Humidifier 6
12 Bryant HUMBBSBP2017-A User manual Humidifier 2
13 Bryant HUMBBSFP1016-A User manual Humidifier 1
14 Bryant HUMBBWTR2019 User manual Humidifier 0
15 Bryant HUMBBWTR2019-A User manual Humidifier 0
16 Edelbrock 15015 User manual Humidifier 0
17 Adam Equipment PAS 16E User manual Humidifier 0
18 Adam Equipment 9618 Revision D User manual Humidifier 11
19 AdobeAir CMC641 User manual Humidifier 9
20 AdobeAir MD524 User manual Humidifier 2