Alpha Industries MTK005 user manual

User manual for the device Alpha Industries MTK005

Device: Alpha Industries MTK005
Category: Humidifier
Manufacturer: Alpha Industries
Size: 0.28 MB
Added : 11/22/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Alpha Industries MTK005. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Alpha Industries MTK005.

For your convenience

If looking through the Alpha Industries MTK005 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Alpha Industries MTK005 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Alpha Industries MTK005 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Alpha Industries MTK005 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Alpha Industries MTK005 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Alpha Industries MTK005. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MANUAL
®
Alpha Moisture Test Kit
Instruction Manual
Part No: MTK005
Version 1
103 Bauer Drive, Oakland, NJ 07436 • 800-648-7229 • Fax: 800-286-0114
www.alpha-tools.com

Summary of the content on the page No. 2

Table of CoNTeNTs Introduction .................................................................................3 ASTM F 1869 Protocol Checklist For Conducting The Calcium Chloride Test ......................................................3 Quantative Test Method for Determining Moisture Vapor Emission Rate (ASTM F 1869) .....................................4 Purpose .............................................................................4 Contents ...........................

Summary of the content on the page No. 3

INTroduCTIoN ® Thank you for purchasing the a lpha Moisture Test Kit, a calcium chloride test for determining if the concrete slab is suitable for floor covering or polymer coating installations. The test works by absorbing moisture in a vapor form that is exiting the slab’s surface due to natural environmental factors over a period of time. The test measures an approximate 70 square inches area of concrete surface for 60 to 72 hours, then a simple calculation is followed that determines th

Summary of the content on the page No. 4

3. Clean the concrete surface of any foreign substances. A foreign substance can be floor covering, adhesive residue, epoxy coating, paint, curing and sealing compounds, waxes, dirt or oil stains, or any other material residue on the slab surface. Remove concrete contaminants by shot blasting, abrasive grinding wheel or diamond cup wheel. The use of wire brushes or razor scraping may not be suitable for achieving a clean, open concrete slab surface. 4. Prepare test area and schedule te

Summary of the content on the page No. 5

of asTM documents can be obtained from american society for Testing and Ma- terials. 100 Barr Harbor Drive, West Conshohocken, PA 19428. Tel: 610-832-9585 Fax: 610-832-9555. The documents may also be purchased on the internet from www.astm.org. ►PreP ara TIoN: 1. Survey Job Site Conditions - Verify environmental controls are operational. The building temperature and humidity should be representative of what it would be during normal use. The temperature should be between 65 to 85 degree an

Summary of the content on the page No. 6

TesT INsTruCTIoNs The following testing procedure is brief and is not meant to replace the most current ASTM standards. Therefore, the User must get acquainted with the applicable current asTM standard and osHa safety regulations prior to using this test kit. sTeP 1 Remove any foreign objects such as overspray, curing compound and sealers from the concrete surface using mechanical devices such as a grinder (photo shows ® alpha Ecogrinder with dust carriage attached). Remove dust from the c

Summary of the content on the page No. 7

sTeP 4 Peel off the paper protective backing from the black seal- ant that is around the dome and discard. Make sure the sealant material does not contact objects or clothing as it is very sticky and intended to provide a secure, longlasting seal to the concrete throughout the duration of the test. sTeP 5 Carefully remove the lid from the container that holds the calcium chloride crystals. do not spill the crystals. It is easiest to turn it over and place it under the dish as shown. It

Summary of the content on the page No. 8

sTeP 8 After 60 to 72 hours, remove the dome with a razor. Retrieve the dish with the calcium chloride and immediately place the lid back on and reseal using saved vinyl tape. Re-weigh the container on the same gram scale used at the start of the test. record weight, date and time (W2) (T2). Note the weight as final weight (W2). Do not spill any of the calcium chloride crystals from the container. If any crystals are spilled, the test must be rerun with a new test kit. CalCula TIoNs 1. D

Summary of the content on the page No. 9

bIas & PreCIsIoN of THe TesT Follow guide lines provided by the latest ASTM. Our experience indicates that the test results may vary with environmental and seasonal changes. The test determines the rate of moisture vapor emission at the time of the test only. It does not predict future moisture vapor emission rate or the performance of the flooring material. The test performed at the same location at a different time may produce different results. Heal TH aNd safeTY The chemical product in

Summary of the content on the page No. 10

CoNCreTe MoIsTure V aPor eMIssIoN loG sHeeT report date: _________________ site location:__________________________________________ Test Conducted by:______________________________Phone: ____________________________ sTarTING da Te of TesT:_________________ eNdING da Te of TesT __________________ building Temperature: ______________________ building Temperature: _____________________ Relative Humidity: __________________________ Relative Humidity:________________________ sTarT of Tes

Summary of the content on the page No. 11

NoTes 11

Summary of the content on the page No. 12

103 Bauer Drive, Oakland, NJ 07436 • 800-648-7229 • Fax: 800-286-0114 www.alpha-tools.com Copyright © 2011 Alpha Professional Tools. All rights reserved. 08/2011


Alternative user manuals
# User manual Category Download
1 Edelbrock 15015 User manual Humidifier 0
2 Adam Equipment PAS 16E User manual Humidifier 0
3 Adam Equipment 9618 Revision D User manual Humidifier 11
4 AdobeAir CMC641 User manual Humidifier 9
5 AdobeAir MD524 User manual Humidifier 2
6 AdobeAir CMC431 User manual Humidifier 15
7 AdobeAir CMC442 User manual Humidifier 1
8 AdobeAir L900790A User manual Humidifier 1
9 AdobeAir CM240 User manual Humidifier 2
10 AdobeAir CMC632 User manual Humidifier 1
11 AdobeAir MMPC12A User manual Humidifier 2
12 AdobeAir CMC441 User manual Humidifier 4
13 AdobeAir MS628 User manual Humidifier 3
14 Air-O-Swiss AOS E2241 User manual Humidifier 107
15 AdobeAir UD960 User manual Humidifier 0