American Power Conversion AFX Series user manual

User manual for the device American Power Conversion AFX Series

Device: American Power Conversion AFX Series
Category: Humidifier
Manufacturer: American Power Conversion
Size: 1.62 MB
Added : 11/22/2013
Number of pages: 80
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for American Power Conversion AFX Series. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with American Power Conversion AFX Series.

For your convenience

If looking through the American Power Conversion AFX Series user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual American Power Conversion AFX Series on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual American Power Conversion AFX Series to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
American Power Conversion AFX Series User manual - Online PDF
Advertisement
« Page 1 of 80 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual American Power Conversion AFX Series but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to American Power Conversion AFX Series. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
TM
NetworkAIR AFX Series
Precision Air-Conditioning Units—60 Hz
Technical Data

Summary of the content on the page No. 2

Contents Available Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Downflow 1 Upflow front-return 1 Upflow rear-return 1 Indoor rear-discharge centrifugal condenser 1 Indoor top-discharge centrifugal condenser 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Introduction 3 Capacity 3 Air pattern 3 Control 3 Configuration 4 Front access 4 Humidity control 4 Compliance 4 Model Selection. . . . . . . .

Summary of the content on the page No. 3

Performance Specifications. . . . . . . . . . . . . . . . . . . . . . . . . 17 Net cooling capacity—air/remote condensing 17 Net cooling capacity—water 18 Net cooling capacity—glycol 19 Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Air system 21 Coolant requirements 21 Pump system 21 Water regulating valve–2-Way/3-Way, single seated 22 Humidification—solid state electrode canister 22 Filters 22 Evaporator coil 22 Compressor—scroll 22 Elec

Summary of the content on the page No. 4

Upflow rear-return—20–28 ton 47 Indoor rear-discharge centrifugal condenser—6–8 ton 48 Indoor rear-discharge centrifugal condenser—10–18 ton 49 Indoor rear-discharge centrifugal condenser—20–28 ton 50 Indoor top-discharge centrifugal condenser—6–8 ton 51 Indoor top-discharge centrifugal condenser—10–18 ton 52 Indoor top-discharge centrifugal condenser—20–28 ton 53 Air-Cooled Condensers and Drycoolers . . . . . . . . . . . . . . . 55 Key to the model number 55 Air-cooled condenser

Summary of the content on the page No. 5

Summary of the content on the page No. 6

Available Models Downflow 6–8 ton 10–18 ton 20–28 ton Upflow front-return 6–8 ton 10–18 ton 20–28 ton Upflow rear-return 6–8 ton 10–18 ton 20–28 ton Indoor rear-discharge centrifugal condenser 6–8 ton 10–18 ton 20–28 ton Indoor top-discharge centrifugal condenser 6–8 ton 10–18 ton 20–28 ton APC NetworkAIR AFX Series: Available Models 1

Summary of the content on the page No. 7

Summary of the content on the page No. 8

Overview Introduction The APC AFX series precision air-conditioning system provides compact, quiet, efficient, and reliable system solutions in the expanding precision air- conditioning market. The AFX series is offered in a wide variety of capacities, configurations, and air patterns within an extremely compact cabinet size. Precision environmental control requirements now reach far beyond the confines of the traditional data center or computer room to encompass a larger suite of applicati

Summary of the content on the page No. 9

Configuration Air-cooled. Unit used with an air-cooled condenser. Refrigerant lines must be run between the indoor unit and the condenser. Air cooled units require low maintenance and have low operating costs. Configurations are:  Air-cooled with remote outdoor condenser.  Air-cooled with indoor floor mounted condenser. Water-cooled. Unit used with a cooling tower or other source of water. Field refrigeration piping is eliminated by a factory sealed and tested system. Water piping to and

Summary of the content on the page No. 10

Model Selection AFX – X X X – X – X X – X U RGX 3 ULWHFHV6 Z RIO R U ; VL H OI S HJDWO & R R O F FD \ WL † $ % P QLO DR QD QW H ; J $ 0 & R D W U Q $ $ULF RROG H D WHUFRRO: : GH F \ ROF RROHG PRWH 5H5 RQVGFQL H J Q APC NetworkAIR AFX Series: Model Selection 5 * *O LR LJXQI .$ ;; QR LQ SDLQJ 9R 8 8 RZ HV ; $) $) ’ ’ ZQ

Summary of the content on the page No. 11

Summary of the content on the page No. 12

Standard Features Microprocessor The microprocessor controller provides state of the art control for a wide variety of environmental applications including the demanding requirements controller of data centers, control rooms, clean rooms, switch rooms, MRI facilities, CAT scan facilities and UPS Rooms. Operator Interface is provided by the four-line, 80-character backlit LCD display. A user-friendly menu structure along with clearly defined prompts allow the operator to easily move about t

Summary of the content on the page No. 13

Configuration options include:  Fahrenheit or celsius display  Alarm input polarity  Compressor minimum on time  Alarm enable  Compressor minimum off time  Temperature deadbands  Power loss restart time delay  Humidity deadbands  Redundant unit grouping  Small room delay Common alarm contact. A common alarm relay is installed on every microprocessor. In the event of an alarm condition, the relay will change state. The user can select which alarms change the state of the relay. This

Summary of the content on the page No. 14

Blower assembly The AFX series includes multiple, centrifugal blower assemblies that have been engineered for quiet, reliable operation. Lower blower speeds reduce noise and extend belt and bearing life to 200,000L hours. Permanently 10 lubricated bearings, a single-belt variable pitch drive, and an adjustable motor base all ensure dependable operation. In addition, the air return patterns evenly distribute air across the cooling coil. Electrical panel The electrical panel contains the con

Summary of the content on the page No. 15

Each refrigeration system includes:  Thermal expansion valve with equalizer  High and low pressure switches  Sight glass with moisture indicator  Filter drier  Liquid line solenoid valve Cooling coil The AFX utilizes dual distributors on one circuit of the refrigeration system. During dehumidification the smaller distributor is turned off effectively reducing the active circuits of the evaporator coil. During this mode of operation the evaporating temperature is decreased, resulting i

Summary of the content on the page No. 16

Emergency drain Systems are provided with two drain pans. The primary stainless steel condensate drain pan lies directly under the cooling coil. A secondary pan emergency drain pan provides additional protection by catching any water before it reaches the subfloor and becomes a problem. An optional factory supplied water detector in the emergency drain pan functions as your early warning system in the event of any water problems. A threaded flange is factory supplied for secondary drain co

Summary of the content on the page No. 17

Summary of the content on the page No. 18

Optional Features The following optional features are available on the AFX Series unless otherwise noted. Certain combinations of options may not be available. Emergency/ Smoke detector(s). The factory installed smoke detector(s) is designed to sense smoke concentration in the return air stream. Upon detecting smoke environmental concentration an audible and visual alarm on the microprocessor will be activated and the unit will immediately shut-down. Firestat. A Firestat is available for i

Summary of the content on the page No. 19

Control/monitoring Custom alarm dry contact closures. Each unit can be equipped with any or all of the listed dry contact closures. Upon activation of the associated alarm, a discreet Normally Open or Normally Closed contact is available for remote monitoring of that discreet alarm.  High Temperature Alarm  Low Temperature Alarm  High Humidity Alarm  Low Humidity Alarm  Compressor High Pressure Alarm  Fan Status Alarm  Change Filter Alarm  Fire Alarm (with addition of optional firesta

Summary of the content on the page No. 20

Reheat Hot water or steam reheat. An on/off solenoid valve for steam reheat, or a modulating valve for hot water reheat maintains the dry bulb temperature when the system is in dehumidification and heat mode. Completely factory pre-piped, the system includes a copper tube, aluminum-fin reheat coil, solenoid valve, float, and thermostatic and steam trap for steam reheat only. Hot gas reheat. The copper tube, aluminum fin hot gas reheat coil maintains the leaving dry bulb temperature when the


Alternative user manuals
# User manual Category Download
1 Edelbrock 15015 User manual Humidifier 0
2 Adam Equipment PAS 16E User manual Humidifier 0
3 Adam Equipment 9618 Revision D User manual Humidifier 11
4 AdobeAir CMC641 User manual Humidifier 9
5 AdobeAir MD524 User manual Humidifier 2
6 AdobeAir CMC431 User manual Humidifier 15
7 AdobeAir CMC442 User manual Humidifier 1
8 AdobeAir L900790A User manual Humidifier 1
9 AdobeAir CM240 User manual Humidifier 2
10 AdobeAir CMC632 User manual Humidifier 1
11 AdobeAir MMPC12A User manual Humidifier 2
12 AdobeAir CMC441 User manual Humidifier 4
13 AdobeAir MS628 User manual Humidifier 3
14 Air-O-Swiss AOS E2241 User manual Humidifier 107
15 AdobeAir UD960 User manual Humidifier 0