Johnson Hardware IB-412 R01 user manual

User manual for the device Johnson Hardware IB-412 R01

Device: Johnson Hardware IB-412 R01
Category: Marine Sanitation System
Manufacturer: Johnson Hardware
Size: 5.13 MB
Added : 11/18/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Johnson Hardware IB-412 R01. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Johnson Hardware IB-412 R01.

For your convenience

If looking through the Johnson Hardware IB-412 R01 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Johnson Hardware IB-412 R01 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Johnson Hardware IB-412 R01 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Johnson Hardware IB-412 R01 User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Johnson Hardware IB-412 R01 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Johnson Hardware IB-412 R01. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Manual

AquaT
Marine Toilet
Manual Operated
IB-412 R01 (0702)

Summary of the content on the page No. 2

Garanti Produkterna har två års garanti. Garanti medges ej vid följande fall: • om skålen är trasig • om de avpassade instruktionerna avseende det elektriska systemet och bruksanvisningen inte följts på rätt sätt. Varning: användning av starka rengöringsmedel för att rengöra toaletten är förbjudet eftersom dessa produkter stannar kvar inuti systemet och bränner igenom pumpens gummitätningar. Eventuella spår funna på reklamerade varor upphäver garantin. För att kunna utnyttja garantin måste s

Summary of the content on the page No. 3

Svenska Bruksanvisning AquaT™ Marintoalett, Manuell Tillämpningar Allmänna instruktioner för samtliga installationer Johnson Pump Comfort och Compact skål manuella marintoaletter Du behöver: kan installeras både i motor- och segelbåtar, antingen ovan eller under • Spiralar merad slätbor rad flexibel slang för både 19 mm (¾”) inre vattenlinjen, för användning till havs, på älvar, sjöar eller kanaler. diameters inlopp och 38 mm (1½”) inre diameters utloppsslang. Avloppet kan antingen ledas över

Summary of the content on the page No. 4

Alternativ 2: Alternativ 3: Toalett över vattenlinjen Toaletten töms till en tank, utloppets vinkelrör är nedan- Du kan använda en 19 mm (¾”) backventil för tankens översta del vid alla tillfällen • Led inloppsslangen den rakaste vägen från inloppetsbottenkran till spolpumpens inloppsanslutning. • För maximal praktisk användning, installera en in-line backventil närmast till inloppets bottenkran vilket säkerställer att pumpen förblir flödad mellan användningar na. • Toalettens spolpump

Summary of the content on the page No. 5

Svenska RÖRDRAGNING SLÄPPER 6. SÄKERHET: All rördragning måste fästas både på portsidan och på de återstående Se till att dessa instruktioner kommer ägaren, skepparen eller båtens med slangklämmor av rostfritt stål. användare tillhanda, eftersom de innehåller viktig säkerhetsinformation Ha i åtanke att eventuella läckage kan orsaka att båten sjunker med OM SLUTFÖRANDE AV installation: STÄNG AV SPOLANORDNINGEN följden att risk för liv uppkommer. ANVÄND SLANGKLÄMMOR! STÄNG BÅDA BOTTENKRANARNA

Summary of the content on the page No. 6

• Under användning, pumpa så mycket som behövs för att hålla 2. MONTERING innehållet för skålen tillräckligt för komfort. Du behöver • Använd ett toalettpapper, hårt eller mjukt, av bra kvalitet för hus- • Bultar av rostfritt stål: 4 st, 8 mm (5/16”) diameter av längd som hållsbruk, men använd inte mer än nödvändigt. passar till monteringsunderlagets tjocklek. • Efter användning, håll spolkontrollen stängd ( ) och pumpa • Muttrar av rostfritt stål: 4 st helst självlåsande. Om du inte an

Summary of the content on the page No. 7

Svenska Service 4 Översyn Du behöver en servicesats som innehåller alla slitdelar, se efter i listan 1 Förberedelse för vinterrustning över delar för mer detaljer. Johnson Pump manuela toaletter är konstruerade för att vara enkla att serva; därför krävs inga specialkunskaper och dessutom krävs inte några specialverktyg. • Spola toaletten i enlighet med driftanvisningarna för normal användning, var särskilt uppmärksam på att allt avfall är borta från VARNING! utloppets rörsystem, att skål

Summary of the content on the page No. 8

Dimensioner & Vikt Modell Nr Beskrivning Net vikt A B C D E F 80-47229-01 Compact skål 9,6 kg 345 650 215 425 450 170 mm 21 lbs 13,58 25,59 8,46 16,73 17,72 6,69 (inch) 80-47230-01 Comfort skål 11 kg 340 705 275 490 470 185 mm 24lbs 13,39 27,76 10,83 19,29 18,50 7,28 (inch) Ø19mm (0,75") Inlet Ø38mm (1,5") Outlet Multi Angle Ø6,8 (0,27") 105-125 (4x) 235 F C 50-55 E 216-226 D Reservdelar och referenslista 10 3 1 4 9 11 4 7 2 8 5 4 6 Pos. Beskrivning Modell Nr Pos. Beskrivning Modell Nr

Summary of the content on the page No. 9

English Johnson Pump Marine Toilet, Manual Applications General instructions for all possible installations Johnson Pump Comfort and Compact bowl manually operated marine You need: toilets can be installed in both power and sailing craft, either above or • Spiral reinforced smooth bore flexible hose for both the 19 mm. below the waterline, for use on sea, river, lake or canal. (3/4") internal diameter inlet and the 38 mm (1 1/2") internal The waste can be discharged either overboard (please

Summary of the content on the page No. 10

Alternative 2: Alternative 3: Toilet above the waterline Toilet waste discharging into holding tank, discharge You may use a 19 mm. (3/4”) non-return valve elbow below top of holding tank at any time • Run the inlet hose by the most direct route from the inlet seacock to the flushing pump inlet tail • For your maximum convenience of use, install an in-line non- return valve next to the inlet seacock which will ensure that the pump stays primed in between usages. • The toilet flushing pu

Summary of the content on the page No. 11

English PIPEWORK LOOSING 6. SAFETY: All pipeworks must be fastened both in the gate side and in the Ensure that these instructions reach the owner, the skipper or the remaining ones with a stainless steel hose clamp. Please keep in mind operator of the craft, as it contains important safety information ON that an eventual leak might cause the craft to sink, with consequent COMPLETION OF Installation: loss of life USE HOSE CLAMPS! SHUT THE FLUSH CONTROL CLOSE BOTH SEACOCKS BOWL RIM BELOW

Summary of the content on the page No. 12

• Drill: Diameter 9mm. AFTER USE: • Silicone sealant, white. • SHUT THE FLUSH CONTROL. ( ) • SHUT BOTH SEACOCKS If you do not use self-locking nuts, you will need some nut-locking compound NOTE: Do not put any of the following into the toilet: Sanitary Towels, Wet Strength Tissues, Cotton Wool, Cigarettes, Matches, 1. Put the toilet in the selected position. Using the holes in the base Chewing Gum or any solid objects, Petrol, Diesel, Oil, Solvents of as a guide, mark the positions for the

Summary of the content on the page No. 13

English LONG AS THE OPERATION HAS BEEN COMPLETED, since if you Reassemble the pump as follows: let it go, it might fall inside the pump. • Push on the new piston O-ring. • Unscrew the seal assembly and slide it off the piston. • F ollow the ser vicing instr uctions for seal replacement and fit the • Wrap one turn of tape around the thread at the top of the piston new seal assembly, the piston assembly and the handle. rod to protect the new seal, slide the new seal down the piston rod • Lub

Summary of the content on the page No. 14

Dimensions & Weight Model No Description Net Weight A B C D E F 80-47229-01 Compact bowl 9,6 kg 345 650 215 425 450 170 mm 21 lbs 13,58 25,59 8,46 16,73 17,72 6,69 (inch) 80-47230-01 Comfort bowl 11 kg 340 705 275 490 470 185 mm 24lbs 13,39 27,76 10,83 19,29 18,50 7,28 (inch) Ø19mm (0,75") Inlet Ø38mm (1,5") Outlet Multi Angle Ø6,8 (0,27") 105-125 (4x) 235 F C 50-55 E 216-226 D Spare Parts & Reference guide 10 3 1 4 9 11 4 7 2 8 5 4 6 Pos. Description Model No Pos. Description Model No

Summary of the content on the page No. 15

Deutch Bedienungsanleitung ™ AquaT Schiffstoilette Manuell betrieben Rohrleitung – die richtige Methode wählen: Anwendungen Sie müssen für das Einlaufrohr aus zwei Möglichkeiten und für das Auslassrohr aus vier Möglichkeiten die richtige Einbaumethode Johnson Pump Comfort und Compact Becken manuell betriebene herausfinden, je nachdem, ob sich die T oilette über oder unter halb der Schiffstoiletten können sowohl in motor- als auch windbetriebenen W asserlinie befindet und ob der Abfall übe

Summary of the content on the page No. 16

• Ersetzen Sie den weißen Schlauch mit einem längeren Schlauch Sie können eine 38 mm (1 1/2”) Rohrschlaufe verwenden. mit einem Innendurchmesser von 19 mm Und ordnen Sie ihn so • Bringen Sie den Auslaufschlauch mindestens 30 cm (12’) über an, dass er wenigstens 20 cm (8”) über der höchstmöglichen den Entsorgungsbogen und montieren Sie danach eine Rohr- Wasserlinie steht, und montieren Sie die belüftete Rohrschlaufe an schlaufe auf den Schlauch, so dass etwas Wasser in dem Fuß der jenen

Summary of the content on the page No. 17

Deutch BECKENKANTE UNTERHALB DER WASSERLINIE: Falls die Toilette an einen Schiffsrumpfstutzen angeschlossen wird und falls die Kante des Beckens unterhalb der Wasserlinie bleibt, kann Wasser eindringen, wonach das Schiff sinken und dadurch Tod verursacht werden kann. Aus diesem Grund muss eine belüftete Rohrschlaufe in alle Rohrleitungen montiert werden, die an einen Schiffsrumpfstutzen angeschlossen werden, falls die Kante der Toilette weniger als 20 cm (8”) über die Wasserlinie während d

Summary of the content on the page No. 18

Falls Sie keine selbstsichernde Muttern verwenden, brauchen Sie ständige auf/ab-Hübe gemacht werden). Schließen Sie etwas Schraubensicherungsmittel. danach die Spülungssteuerung und pumpen Sie, bis das Becken leer ist. Lassen Sie das Becken immer leer, um Geruch und 1. Stellen Sie die Toilette in die gewählte Stellung auf. Markieren Sie Verstopfung zu minimieren. die Stellungen für 4 Bolzen auf die Montageober fläche, indem Sie die Bohrungen im Fuß als Hilfe benutzen. Entfernen Sie d

Summary of the content on the page No. 19

Deutch • Wischen Sie jegliches Wasser ab, das aus dem System treten Entfernen Sie die Pumpe wie folgt: kann. • Lösen Sie die drei Schlauchklemmen; entfernen Sie den Einlass- schlauch und den Verbindungsschlauch vom Oberteil der Pumpe. • Entfer nen Sie die 2 Schrauben, die die Entsorgungsflansche und 2 Dichtung ersetzen den Bogen mit dem Pumpenzylinder verbinden. Falls Wasser um die Kolbestange im Oberteil der Pumpe austritt, • Entfernen Sie NICHT die Schlauchklemmen und den Schlauch b

Summary of the content on the page No. 20

Abmessungen und Gewichte Modell Nr Beschreibung Nettogewicht A B C D E F 80-47229-01 Becken Compact 9,6 kg 345 650 215 425 450 170 mm 21 lbs 13,58 25,59 8,46 16,73 17,72 6,69 (inch) 80-47230-01 Becken Comfort 11 kg 340 705 275 490 470 185 mm 24lbs 13,39 27,76 10,83 19,29 18,50 7,28 (inch) Ø19mm (0,75") Inlet Ø38mm (1,5") Outlet Multi Angle Ø6,8 (0,27") 105-125 (4x) 235 F C 50-55 E 216-226 D Ersatzteile und Bezug 10 3 1 4 9 11 4 7 2 8 5 4 6 Pos. Beschreibung Modell Nr. Pos. Beschreibun


Alternative user manuals
# User manual Category Download
1 ACS A0565547 User manual Marine Sanitation System 4
2 ACS XFC-S User manual Marine Sanitation System 1
3 American Standard M968757D User manual Marine Sanitation System 1
4 Attwood 4133 User manual Marine Sanitation System 2
5 Attwood 30116 User manual Marine Sanitation System 1
6 Attwood 4131 User manual Marine Sanitation System 1
7 Dometic VACUFLUSH 1600 User manual Marine Sanitation System 9
8 Central Pneumatic Air Compressor 97956 User manual Marine Sanitation System 1
9 Emerson Process Management 51000 User manual Marine Sanitation System 3
10 Hayward Pools HAYWARD POOL SYSTEM CONTROL User manual Marine Sanitation System 13
11 Honda Power Equipment WDP30X User manual Marine Sanitation System 2
12 ATD Tools ATD-8525 User manual Marine Sanitation System 0
13 CMS Products 780 User manual Marine Sanitation System 0
14 Attwood 6126 User manual Marine Sanitation System 1
15 Attwood 4132 User manual Marine Sanitation System 3