Panasonic CS-MKE12NKU user manual

User manual for the device Panasonic CS-MKE12NKU

Device: Panasonic CS-MKE12NKU
Category: Air Conditioner
Manufacturer: Panasonic
Size: 2.63 MB
Added : 4/16/2014
Number of pages: 122
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Panasonic CS-MKE12NKU. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Panasonic CS-MKE12NKU.

For your convenience

If looking through the Panasonic CS-MKE12NKU user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Panasonic CS-MKE12NKU on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Panasonic CS-MKE12NKU to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Panasonic CS-MKE12NKU User manual - Online PDF
Advertisement
« Page 1 of 122 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Panasonic CS-MKE12NKU but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Panasonic CS-MKE12NKU. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TECHNICAL & SERVICE MANUAL
INDOOR UNIT : CS-MKE7NKU
CS-MKE9NKU
CS-MKE12NKU
CS-MKE18NKU
CS-MKE24NKU
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
Capacity Indoor Model No. Product Code No.
7,500BTU / h CS-MKE7NKU 1 852 360 99
9,000BTU / h CS-MKE9NKU 1 852 361 00
11,900BTU / h CS-MKE12NKU 1 852 361 01
17,500BTU / h CS-MKE18NKU 1 852 361 02
24,200BTU / h CS-MKE24NKU 1 852 361 03
Wall Mounted Type Indoor Unit
< Applicable Multi-Outdoor Units >
CU-3KE19NBU (3-room multi unit)
CU-4KE24NBU (4-room multi uni

Summary of the content on the page No. 2

SAFETY PRECAUTIONS • Before doing repair work, please read the " SAFETY PRECAUTIONS" carefully and fully understand them. • The precautionary items here are divided into " Warning" and " Caution" items. Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly, are included in the " Warning" table. However, even precautionary items identified as " Caution" also have the potential for serious consequences if

Summary of the content on the page No. 3

Warning If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite. Prohibit If refrigerant gas leaks during the work, ventilate the room. If refrigerant gas catches fire, harmful gas may be generated. Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle. If air or other contaminants mix with the gas, pressure will become extremely high in the refrigerating cycle, which may cause a unit breakdown." Prohibit When th

Summary of the content on the page No. 4

Table of Contents Page ............................................................................................................. SAFETY PRECAUTIONS 2 .................................................................................................................... TABLE OF CONTENTS 4 ................................................................................... APPLICABLE MULTI-OUTDOOR UNITS 5 ....................................................................................

Summary of the content on the page No. 5

APPLICABLE MULTI-OUTDOOR UNITS Multi-Outdoor Unit 3-Room 4-Room 4-Room CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU Indoor Unit CS-MKE7NKU YES YES YES CS-MKE9NKU YES YES YES CS-MKE12NKU YES YES YES CS-MKE18NKU YES YES YES CS-MKE24NKU NO YES YES 5

Summary of the content on the page No. 6

1. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 °F DB / 71 °F WB 115° F DB Cooling Minimum 67 °F DB / 57 °F WB 14° F DB Maximum 80 °F DB / 67 °F WB 75° F DB / 65 °F WB Heating Minimum – DB / – WB – DB / 0 °F WB 6

Summary of the content on the page No. 7

2. SPECIFICATIONS 2-1. Unit Specifications Indoor Unit CS-MKE7NKU < 230V > Type Wall Mounted Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Performance Cooling Heating Capacity BTU/h 7,500 8,500 kW 2.20 2.50 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 241(410) / 224(381) / 212(360) 271(460) / 241(410) / 218(370) Moisture Removal (High) Pints/h 2.77 - Electrical Rating Cooling Heating Available Voltage Range V 187 to 253 Running Amperes A 0.11 0.11 Power Input W 25 25 Features Contr

Summary of the content on the page No. 8

Indoor Unit CS-MKE7NKU < 208V > Type Wall Mounted Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Performance Cooling Heating Capacity BTU/h 7,500 8,500 kW 2.20 2.50 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 241(410) / 224(381) / 212(360) 271(460) / 241(410) / 218(370) Moisture Removal (High) Pints/h 2.77 - Electrical Rating Cooling Heating Available Voltage Range V 187 to 253 Running Amperes A 0.12 0.12 Power Input W 25 25 Features Control / Temperature Control Microprocessor / I.C

Summary of the content on the page No. 9

Indoor Unit CS-MKE9NKU < 230V > Type Wall Mounted Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Performance Cooling Heating Capacity BTU/h 9,000 12,200 kW 2.65 3.60 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 259(440) / 241(410) / 212(360) 282(479) / 271(460) / 218(370) Moisture Removal (High) Pints/h 3.4- Electrical Rating Cooling Heating Available Voltage Range V 187 to 253 Running Amperes A 0.15 0.15 Power Input W 35 35 Features Control / Temperature Control Microprocessor / I.C.

Summary of the content on the page No. 10

Indoor Unit CS-MKE9NKU < 208V > Type Wall Mounted Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Performance Cooling Heating Capacity BTU/h 9,000 12,200 kW 2.65 3.60 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 259(440) / 241(410) / 212(360) 282(479) / 271(460) / 218(370) Moisture Removal (High) Pints/h 3.4- Electrical Rating Cooling Heating Available Voltage Range V 187 to 253 Running Amperes A 0.17 0.17 Power Input W 35 35 Features Control / Temperature Control Microprocessor / I.C.

Summary of the content on the page No. 11

Indoor Unit CS-MKE12NKU < 230V > Type Wall Mounted Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Performance Cooling Heating Capacity BTU/h 11,900 14,300 kW 3.50 4.20 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 282(479) / 259(440) / 218(370) 294(500) / 271(460) / 218(370) Moisture Removal (High) Pints/h 4.26 - Electrical Rating Cooling Heating Available Voltage Range V 187 to 253 Running Amperes A 0.15 0.15 Power Input W 35 35 Features Control / Temperature Control Microprocessor /

Summary of the content on the page No. 12

Indoor Unit CS-MKE12NKU < 208V > Type Wall Mounted Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Performance Cooling Heating Capacity BTU/h 11,900 14,300 kW 3.50 4.20 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 282(479) / 259(440) / 218(370) 294(500) / 271(460) / 218(370) Moisture Removal (High) Pints/h 4.26 - Electrical Rating Cooling Heating Available Voltage Range V 187 to 253 Running Amperes A 0.17 0.17 Power Input W 35 35 Features Control / Temperature Control Microprocessor /

Summary of the content on the page No. 13

Indoor Unit CS-MKE18NKU < 230V > Type Wall Mounted Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Performance Cooling Heating Capacity BTU/h 17,500 20,400 kW 5.15 6.00 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 500(850) / 447(760) / 377(641) 500(850) / 435(739) / 377(641) Moisture Removal (High) Pints/h 4.89 - Electrical Rating Cooling Heating Available Voltage Range V 187 to 253 Running Amperes A 0.15 0.15 Power Input W 35 35 Features Control / Temperature Control Microprocessor /

Summary of the content on the page No. 14

Indoor Unit CS-MKE18NKU < 208V > Type Wall Mounted Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Performance Cooling Heating Capacity BTU/h 17,500 20,400 kW 5.15 6.00 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 500(850) / 447(760) / 377(641) 500(850) / 435(739) / 377(641) Moisture Removal (High) Pints/h 4.89 - Electrical Rating Cooling Heating Available Voltage Range V 187 to 253 Running Amperes A 0.17 0.17 Power Input W 35 35 Features Control / Temperature Control Microprocessor /

Summary of the content on the page No. 15

Indoor Unit CS-MKE24NKU < 230V > Type Wall Mounted Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Performance Cooling Heating Capacity BTU/h 24,200 29,000 kW 7.10 8.50 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 541(919) / 500(850) / 435(739) 541(919) / 488(829) / 435(739) Moisture Removal (High) Pints/h 4.89 - Electrical Rating Cooling Heating Available Voltage Range V 187 to 253 Running Amperes A 0.20 0.20 Power Input W 45 45 Features Control / Temperature Control Microprocessor /

Summary of the content on the page No. 16

Indoor Unit CS-MKE24NKU < 208V > Type Wall Mounted Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Performance Cooling Heating Capacity BTU/h 24,200 29,000 kW 7.10 8.50 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 541(919) / 500(850) / 435(739) 541(919) / 488(829) / 435(739) Moisture Removal (High) Pints/h 4.89 - Electrical Rating Cooling Heating Available Voltage Range V 187 to 253 Running Amperes A 0.22 0.22 Power Input W 45 45 Features Control / Temperature Control Microprocessor /

Summary of the content on the page No. 17

2-2. Major Component Specifications 2-2-1. Indoor Unit Indoor Unit CS-MKE7NKU Control PCB Part No. CB-CS-MKE7NKU Controls Microprocessor Control Circuit Fuse 250V 3A Fan Type Cross-Flow Q'ty ... Dia. and Length inch (mm) 1 ... D3-5/8 / L24-31/32 (D92/L634) Fan Motor Type DC Motor Model ... Q'ty SIC-41CVJ-D847-4 ... 1 No. of Poles 8 Rough Measure RPM (Cool / Heat) 1,050 / 1,100 Nominal Output W 47 Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Internal Controller Over-

Summary of the content on the page No. 18

Indoor Unit CS-MKE9NKU Control PCB Part No. CB-CS-MKE9NKU Controls Microprocessor Control Circuit Fuse 250V 3A Fan Type Cross-Flow Q'ty ... Dia. and Length inch (mm) 1 ... D3-5/8 / L24-31/32 (D92/L634) Fan Motor Type DC Motor Model ... Q'ty SIC-41CVJ-D847-4 ... 1 No. of Poles 8 Rough Measure RPM (Cool / Heat) 1,100 / 1,150 Nominal Output W 47 Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Internal Controller Over-Current Protection Yes Over-Heat Protection Yes Run Cap

Summary of the content on the page No. 19

Indoor Unit CS-MKE12NKU Control PCB Part No. CB-CS-MKE12NKU Controls Microprocessor Control Circuit Fuse 250V 3A Fan Type Cross-Flow Q'ty ... Dia. and Length inch (mm) 1 ... D3-5/8 / L24-31/32 (D92/L634) Fan Motor Type DC Motor Model ... Q'ty SIC-41CVJ-D847-4 ... 1 No. of Poles 8 Rough Measure RPM (Cool / Heat) 1,200 / 1,200 Nominal Output W 47 Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Internal Controller Over-Current Protection Yes Over-Heat Protection Yes Run C

Summary of the content on the page No. 20

Indoor Unit CS-MKE18NKU Control PCB Part No. CB-CS-MKE18NKU Controls Microprocessor Control Circuit Fuse 250V 3A Fan Type Cross-Flow Q'ty ... Dia. and Length inch (mm) 1 ... D3-5/8 / L33-9/32 (D92/L845) Fan Motor Type DC Motor Model ... Q'ty SIC-41CVJ-D847-3 ... 1 No. of Poles 8 Rough Measure RPM (Cool / Heat) 1,200 / 1,200 Nominal Output W 30 Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Internal Controller Over-Current Protection Yes Over-Heat Protection Yes Run Ca


Alternative user manuals
# User manual Category Download
1 Panasonic CS-1873KR User manual Air Conditioner 243
2 Panasonic CS-A12CKPG User manual Air Conditioner 72
3 Panasonic CS-A12CKP User manual Air Conditioner 98
4 Panasonic AC Robot 2006/2007 User manual Air Conditioner 45
5 Panasonic 2008 User manual Air Conditioner 83
6 Panasonic CS-A18CTP User manual Air Conditioner 28
7 Panasonic AW-PS505 User manual Air Conditioner 6
8 Panasonic CS-A12CTP User manual Air Conditioner 31
9 Panasonic CS-A24CTP User manual Air Conditioner 36
10 Panasonic CS-A24CKPG User manual Air Conditioner 4
11 Panasonic CS-A7CKP User manual Air Conditioner 207
12 Panasonic CS-A9CKP User manual Air Conditioner 45
13 Panasonic CS-A9CKPG User manual Air Conditioner 9
14 Panasonic CS-C12CKP User manual Air Conditioner 19
15 Panasonic CS-C24BKP User manual Air Conditioner 33
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21