Panasonic CS-KE36NKU user manual

User manual for the device Panasonic CS-KE36NKU

Device: Panasonic CS-KE36NKU
Category: Air Conditioner
Manufacturer: Panasonic
Size: 2.8 MB
Added : 4/16/2014
Number of pages: 112
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Panasonic CS-KE36NKU. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Panasonic CS-KE36NKU.

For your convenience

If looking through the Panasonic CS-KE36NKU user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Panasonic CS-KE36NKU on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Panasonic CS-KE36NKU to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Panasonic CS-KE36NKU User manual - Online PDF
Advertisement
« Page 1 of 112 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Panasonic CS-KE36NKU but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Panasonic CS-KE36NKU. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TECHNICAL & SERVICE MANUAL
CS-KE30NKU + CU-KE30NKU
CS-KE36NKU + CU-KE36NKU
DC INVERTER SPLIT SYSTEM AIR CONDITIONER
Indoor Model No. Product Code No. Outdoor Model No. Product Code No.
CS-KE30NKU 1 852 360 88 CU-KE30NKU 1 852 360 82
CS-KE36NKU 1 852 360 89 CU-KE36NKU 1 852 360 83
Indoor Unit Outdoor Unit
CS-KE30NKU
CS-KE36NKU
CU-KE30NKU
CU-KE36NKU
IMPORTANT
These air conditioners employ new
refrigerant R410A.
Pay special attention when
servicing the unit.
REFERENCE NO. SM700876
NDITIONER
AIR CO

Summary of the content on the page No. 2

SAFETY PRECAUTIONS • Before doing repair work, please read the " SAFETY PRECAUTIONS" carefully and fully understand them. • The precautionary items here are divided into " Warning" and " Caution" items. Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly, are included in the " Warning" table. However, even precautionary items identified as " Caution" also have the potential for serious consequences if

Summary of the content on the page No. 3

Warning If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite. Prohibit If refrigerant gas leaks during the work, ventilate the room. If refrigerant gas catches fire, harmful gas may be generated. Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle. If air or other contaminants mix with the gas, pressure will become extremely high in the refrigerating cycle, which may cause a unit breakdown." Prohibit When th

Summary of the content on the page No. 4

Table of Contents Page SAFETY PRECAUTIONS .............................................................................................................. 2 TABLE OF CONTENTS ..................................................................................................................... 4 1. OPERATING RANGE ................................................................................................................... 6 2. SPECIFICATIONS 2-1. Unit Specifications ...................

Summary of the content on the page No. 5

Page 9. CHECKING ELECTRICAL COMPONENTS 9-1. Measurement of Insulation Resistance ............................................................................... 51 9-2. Checking Continuity of Fuse on PCB Ass'y ......................................................................... 52 10. REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN SERVICING UNIT 10-1. Characteristics of New Refrigerant R410A ......................................................................... 53 10-2. Checklist before

Summary of the content on the page No. 6

1. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 °F DB / 71 °F WB 115 °F DB Cooling Minimum 67 °F DB / 57 °F WB 0 °F DB Maximum 80 °F DB / 67 °F WB 75 °F DB / 65 °F WB Heating Minimum – DB / – WB – DB / 0 °F WB 6

Summary of the content on the page No. 7

2. SPECIFICATIONS 2-1. Unit Specifications Indoor Unit CS-KE30NKU Outdoor Unit CU-KE30NKU < 230V > Voltage Rating 230V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 30,600 ( 10,900 to 30,600 ) 33,000 ( 14,000 to 33,000 ) kW 9.0 ( 3.2 to 9.0 ) 9.7 ( 4.1 to 9.7 ) Sensible Capacity 18,600 - BTU/h Latent Capacity BTU/h 12,000 - 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 630(1,070)/530(901)/412(700) 671(1,140)/559(950)/441(749) Moisture Removal (High) Pints/h 9.57 - Available Voltage R

Summary of the content on the page No. 8

Indoor Unit CS-KE30NKU Outdoor Unit CU-KE30NKU < 208V > Voltage Rating 208V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 30,600 ( 10,900 to 30,600 ) 33,000 ( 14,000 to 33,000 ) kW 9.0 ( 3.2 to 9.0 ) 9.7 ( 4.1 to 9.7 ) Sensible Capacity 18,600 - BTU/h Latent Capacity BTU/h 12,000 - 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 630(1,070)/530(901)/412(700) 671(1,140)/559(950)/441(749) Moisture Removal (High) Pints/h 9.57 - Available Voltage Range V 187 to 253 Running Amperes A 18.0 ( 5.

Summary of the content on the page No. 9

Indoor Unit CS-KE36NKU Outdoor Unit CU-KE36NKU < 230V > Voltage Rating 230V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 34,000 ( 10,900 to 34,000 ) 36,000 ( 14,000 to 36,000 ) kW 10.0 ( 3.2 to 10.0 ) 10.5 ( 4.1 to 10.5 ) Sensible Capacity 20,700 - BTU/h Latent Capacity BTU/h 13,300 - 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 630(1,070)/530(901)/412(700) 671(1,140)/559(950)/441(749) Moisture Removal (High) Pints/h 10.64 - Available Voltage Range V 187 to 253 Running Amperes A 20.0

Summary of the content on the page No. 10

Indoor Unit CS-KE36NKU Outdoor Unit CU-KE36NKU < 208V > Voltage Rating 208V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 34,000 ( 10,900 to 34,000 ) 36,000 ( 14,000 to 36,000 ) kW 10.0 ( 3.2 to 10.0 ) 10.5 ( 4.1 to 10.5 ) Sensible Capacity 20,700 - BTU/h Latent Capacity BTU/h 13,300 - 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 630(1,070)/530(901)/412(700) 671(1,140)/559(950)/441(749) Moisture Removal (High) Pints/h 10.64 - Available Voltage Range V 187 to 253 Running Amperes A 21.

Summary of the content on the page No. 11

2-2. Major Component Specifications 2-2-1. Indoor Unit Indoor Unit CS-KE30NKU Control PCB Part No. CB-CS-KE30NKU Controls Microprocessor Control Circuit Fuse 250V 3A Fan Type Cross-Flow Q'ty ... Dia. and Length inch (mm) 1 ... D3-15/16 / L32-1 (D100/L838) Fan Motor Type DC Motor Model ... Q'ty SIC-41CVJ-D847-1 ... 1 No. of Poles 8 Rough Measure RPM (Cool / Heat) 1,370 / 1,450 Nominal Output W 47 Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Internal Controller Over-C

Summary of the content on the page No. 12

Indoor Unit CS-KE36NKU Control PCB Part No. CB-CS-KE36NKU Controls Microprocessor Control Circuit Fuse 250V 3A Fan Type Cross-Flow Q'ty ... Dia. and Length inch (mm) 1 ... D3-15/16 / L32-1 (D100/L838) Fan Motor Type DC Motor Model ... Q'ty SIC-41CVJ-D847-1 ... 1 No. of Poles 8 Rough Measure RPM (Cool / Heat) 1,370 / 1,450 Nominal Output W 47 Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Internal Controller Over-Current Protection Yes Over-Heat Protection Yes Run Capaci

Summary of the content on the page No. 13

2-2-2. Outdoor Unit Outdoor Unit CU-KE30NKU P.C.Board Control P.C.B Noise Filer P.C.B H.I.C.Board Part No. CR-CH3082-F POW-CH3082-B2 HIC-CH3072R-C1 Controls Microprocessor - - Circuit Fuse 400V 3.15A 250V 25A - Compressor Type DC Twin Rotary (Hermetic) Compressor Model / Nominal Output C-9RVN273H0H / 2,250W Compressor Oil ... Amount Pints (cc) FV68S ... 2.98 (1,400) Coil Resistance (Ambient Temp. 77 °F (25 °C)) Ohm T - R : 0.169 T - S : 0.169 R - S : 0.169 Safety Device CT (Peak current c

Summary of the content on the page No. 14

Outdoor Unit CU-KE36NKU P.C.Board Control P.C.B Noise Filer P.C.B H.I.C.Board Part No. CR-CH3682-F POW-CH3082-B2 HIC-CH3072R-C1 Controls Microprocessor - - Circuit Fuse 400V 3.15A 250V 25A - Compressor Type DC Twin Rotary (Hermetic) Compressor Model / Nominal Output C-9RVN273H0H / 2,500W Compressor Oil ... Amount Pints (cc) FV68S ... 2.98 (1,400) Coil Resistance (Ambient Temp. 77 °F (25 °C)) Ohm T - R : 0.169 T - S : 0.169 R - S : 0.169 Safety Device CT (Peak current cut-off control) Yes C

Summary of the content on the page No. 15

2-3. Other Component Specifications Indoor Unit CS-KE30NKU CS-KE36NKU Outdoor Unit CU-KE30NKU CU-KE36NKU • Indoor heat exchanger sensor (Model:PTM-D51H-S6-1) • Indoor air temp sensor • Compressor temp sensor (Model:KTEC-35-135-1) (Model:TKS335B) 10 200 9 180 8 160 7 140 6 120 5 100 4 80 3 60 2 40 1 20 0 0 50 59 68 77 86 95 104 32 50 68 86 104 122 140 158 176 194 (10) (15) (20) (25) (30) (35) (40) (0) (10) (20) (30) (40) (50) (60) (70) (80) (90) Temperature °F (°C) Temperature °F (°C)

Summary of the content on the page No. 16

3. DIMENSIONAL DATA Indoor Unit CS-KE30NKU CS-KE36NKU Unit: inch(mm) (852-0-0010-196-00-0) 16 dia. 3-5/32 41-15/16 (1065) 2-3/32 25/32 1-27/32 1-3/32 2-3/8 7-25/32 Wide tube dia. 5/8" (15.88) 5-27/32 9-1/16 (230) (3/32) Narrow tube dia. 3/8" (9.52) 15-1/8 17-23/32 9-3/32 5-1/2 3-3/4 3-3/4 7-7/8 7/16 3-3/8 2-5/8 2-5/8 6-7/32 5-3/16 16-11/32 16-11/32 17-5/16 17-21/32 19-9/16 22-3/8 dia. 3-5/32 2-3/8 11-13/16 (300) 11-13/16 4-9/16 1-7/8 23/32 7-23/32 2-11/16 2-3/4 1-9/32 5-9/16 1-7/8 1-15/32 4-9

Summary of the content on the page No. 17

Outdoor Unit CU-KE30NKU CU-KE36NKU 17 4-11/32 6-11/6 25-31/32 2-ID:1-1/4 holes (holes for drain) Of the 4-ID:1-1/4 holes, use 1 of 2 holes 4-1/8 8-5/8 2-15/16 2-15/16 2-3/8 specified for drain use to install the port. Use rubber plugs to seal the remaining 3 holes. 1/2 1/2 37-1/32 (940) Refrigerant tubing joint (Liquid tube) Flare connection dia.3/8" (9.52) Refrigerant tubing joint (Gas tube) Flare connection dia.5/8" (15.88) 3/4 2-3/8 1-3/16 2-3/8 Wiring outlet 2-5/32 7/16 3/4 (knock-out hol

Summary of the content on the page No. 18

4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram Indoor Unit CS-KE30NKU Outdoor Unit CU-KE30NKU CS-KE36NKU CU-KE36NKU Indoor unit Outdoor unit Sub Main Accumulator Accumulator Wide tube service Wide tube valve High pressure switch Muffler O.D H.P. 5/8" (15.88 mm) 4-way valve Electric Narrow expansion tube valve service Narrow tube M valve Cooling cycle (Defrosting cycle) Strainer O.D. 3/8" Heating cycle (9.52 mm) 18 Heat exchanger Heat exchanger Compressor

Summary of the content on the page No. 19

5. PERFORMANCE DATA 5-1. Temperature Charts Indoor Unit CS-KE30NKU Outdoor Unit CU-KE30NKU Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (60Hz, 230V) (1) Low pressure performance chart Lo fan Hi Fan 174 (1.2) 159 (1.1) 145 (1.0) 131 (0.9) 117 (0.8) 104 (0.7) -4 5 14 23 32 41 50 59 68 77 86 95 104 (-20) (-15) (-10) (-5) (0) (5) (10) (15) (20) (25) (30) (35) (40) Outdoor inlet air DB temp. °F(°C) (2) Operating current performance chart 28 Lo fan Hi Fan 26 24 22 20 18 16 14 12 1

Summary of the content on the page No. 20

Indoor Unit CS-KE30NKU Outdoor Unit CU-KE30NKU Heating Characteristics (RH : 46%, Indoor fan speed : High fan) (60Hz, 230V) (1) High pressure performance chart 494 (3.4) 421 (2.9) 348 (2.4) 275 (1.9) 23 32 41 50 59 68 77 (Ð5) (0) (5) (10) (15) (20) (25) Outdoor inlet air DB temp. °F(°C) (2) Operating current performance chart 19 18 17 16 15 14 13 23 32 41 50 59 68 77 (Ð5) (0) (5) (10) (15) (20) (25) Outdoor inlet air DB temp. °F(°C) (3) Indoor discharge air performance chart 131(55) 122(50)


Alternative user manuals
# User manual Category Download
1 Panasonic CS-1873KR User manual Air Conditioner 243
2 Panasonic CS-A12CKPG User manual Air Conditioner 72
3 Panasonic CS-A12CKP User manual Air Conditioner 98
4 Panasonic AC Robot 2006/2007 User manual Air Conditioner 45
5 Panasonic 2008 User manual Air Conditioner 83
6 Panasonic CS-A18CTP User manual Air Conditioner 28
7 Panasonic AW-PS505 User manual Air Conditioner 6
8 Panasonic CS-A12CTP User manual Air Conditioner 31
9 Panasonic CS-A24CTP User manual Air Conditioner 36
10 Panasonic CS-A24CKPG User manual Air Conditioner 4
11 Panasonic CS-A7CKP User manual Air Conditioner 207
12 Panasonic CS-A9CKP User manual Air Conditioner 45
13 Panasonic CS-A9CKPG User manual Air Conditioner 9
14 Panasonic CS-C12CKP User manual Air Conditioner 19
15 Panasonic CS-C24BKP User manual Air Conditioner 33
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21