Chauvet COLORMIST MIST-CON user manual

User manual for the device Chauvet COLORMIST MIST-CON

Device: Chauvet COLORMIST MIST-CON
Category: Landscape Lighting
Manufacturer: Chauvet
Size: 0.46 MB
Added : 3/21/2013
Number of pages: 13
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Chauvet COLORMIST MIST-CON. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Chauvet COLORMIST MIST-CON.

For your convenience

If looking through the Chauvet COLORMIST MIST-CON user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Chauvet COLORMIST MIST-CON on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Chauvet COLORMIST MIST-CON to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Chauvet COLORMIST MIST-CON User manual - Online PDF
Advertisement
« Page 1 of 13 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Chauvet COLORMIST MIST-CON but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Chauvet COLORMIST MIST-CON. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

COLORmist™ System
MIST-PAR80
COLORmist™ (Par)
MIST-PANEL
COLORmist™ Panel
MIST-CON
COLORmist™ Controller
MIST-PS8
COLORmist™ Power Unit

USER MANUAL

th
CHAUVET, 3000 N 29 Ct, Hollywood, FL 33020 U.S.A
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
2005-10-10/18:36

Summary of the content on the page No. 2

Table of Content BEFORE YOU BEGIN....................................................................................................................................................... 3 COLORMIST™ SYSTEM.................................................................................................................................................................................................. 3 UNPACKING INSTRUCTIONS.....................................................................

Summary of the content on the page No. 3

BEFORE YOU BEGIN COLORmist™ System Your COLORmist™ LED color system may include either of the two packages listed; SYS-PAR4, PAR Pack System SYS-PANEL2, Panel Pack System 1 x MIST-CON, Controller 1 x MIST-CON, Controller 4 x MIST-PAR80, Par Can 2 x MIST-PANEL, Panel 1 x MIST-PS8, Power Unit 1 x MIST-PS8, Power Unit 1 x MIST-CBL33, Power/Signal Cable 33’ 1 x MIST-CBL33, Power/Signal Cable 33’ 4 x MIST-CBL5, Power/Signal Cable 5’ 2 x MIST-CBL5, Power/Signal Cable 5’ User Manual & War

Summary of the content on the page No. 4

INTRODUCTION Features COLORmist™ (MIST-PAR80) COLORmist™ Panel (MIST-PANEL)  80 LEDs per surface  72 LEDs per Panel, distributed into 4 square sections - Red (27), Green (27) and Blue (26) with 18 LEDs each - Red (24), Green (24) and Blue (24)  Ultra bright LED's  Ultra bright LED's  Stand alone color change programs using (COLORmist™ Power unit)  Stand alone color change programs using (COLORmist™ Power unit)  7 static colors, 13 color pattern chase programs with adjus

Summary of the content on the page No. 5

Operating Instructions Product Overview SEGMENT BUTTONS BUTTONS Menu Returns to Main Menu Setup Enter menu selection Steps backward through Up menu functions Steps forward through Down menu functions Audio Enables Sound Activation Power Switch Turns on controller A B D C COLORmist™ Controller Rear Panel ITEM DESCRIPTION A 3-Pin female XLR DMX output connector Input and Output 4-conductor Hanging yoke connectors. B 3-Pin male XLR DMX input connector Used for both pow

Summary of the content on the page No. 6

Operating Instructions SETUP Power Warning! Verify that the power indicator label on your unit matches the line voltage applied. All fixtures must be connected to circuits with a suitable Earth Ground.  To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart.  A fixture’s listed current rating is its average current draw under normal conditions.  All fixtures must be powe

Summary of the content on the page No. 7

OPERATING INSTRUCTIONS Control Panel On the control panel you can set the controller for single action mode where preset programs are run either statically, automatically or by sound-activation or assign a starting DMX channel address. [MENU] Returns to Main menu or step backward through functions [SET UP] Enters menu selection [UP] Steps backward through menu selection [DOWN] Steps forward through menu selection MENU SETUP UP DOWN Menu Diagram System Setup You will need to le

Summary of the content on the page No. 8

Operating Instructions Single Action Programs Single Action programs are pre-built chase and flow patterns. They can be executed either manually or by DMX control. Depending on the program the following attributes can be modified; Run Speed, Flash Frequency and Color Selection. NUMBER PROGRAM TYPE MODIFICATIONS (MODIFIER) 1 Black Static None 2 Red Static None 3 Green Static None 4 Blue Static None 5 Yellow Static None 6 Purple Static None 7 Cyan Static None 8 White Static None

Summary of the content on the page No. 9

Operating Instructions DMX Control Mode With exception to the system setup process all control functions on the controller can be accessed and executed externally via a Universal DMX controller. First you must connect the LED-CHVA controller to an existing DMX daisy chain. The controller is addressable just like any other DMX device or fixture and it will be controlled as if it were a fixture in most intelligent light consoles. Setting the DMX address 1. Press the MODE button until the

Summary of the content on the page No. 10

APPENDIX DMX Primer There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX-512 will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in advanc

Summary of the content on the page No. 11

Appendix DMX Channel Values DEFAULT VALUE FUNCTION Programs 000  009 Black 010  019 Red 020  029 Green 030  039 Blue 040  049 Yellow 050  059 Purple 060  069 Light Blue 070  079 White 080  089 Color Change 090  099 Slow Flow 1 100  109 Slow Flow 2 1 110  119 Roll Chase 1 120  129 Roll Chase 2 130  139 Multi Color 140  149 Fast Flow 1 150  159 Fast Flow 2 160  169 Fast Flow 3 170  179 Fast Flow 4 180  189 2 Color Chase 190  199 2 Color Flow 20

Summary of the content on the page No. 12

MIST-PS8 (Power Unit) Configurations The MIST-PS8 provides power to both the Panel and Par LED fixtures. The diagram below illustrates the number of fixtures along with the cable length the power unit is capable of accommodating. 132 feet (40.2m) length (MAXIMUM LENGTH) 1 1 2 3 4 MIST-CBL33 33’ (10m) cables MIST-PS8 Power Unit MIST-PAR80 or MIST-PANEL 120 feet (36.5m) length 2 1 2 3 4 5 6 7 8 MIST-PS8 Power Unit MIST-CBL15 MIST-PAR80 or MIST-PANEL 15’ (4.5m) cables 60 feet (

Summary of the content on the page No. 13

Appendix Technical Specifications MIST-PANEL Length...................................................................................................................... 302 mm (11.88 in) Width.............................................................................................................................305 mm (12 in) Height ..........................................................................................................................29 mm (1.13 in) Weight....


Alternative user manuals
# User manual Category Download
1 Chauvet 10:14 User manual Landscape Lighting 1
2 Chauvet 3.1 User manual Landscape Lighting 1
3 Chauvet 300e User manual Landscape Lighting 0
4 Chauvet 350 User manual Landscape Lighting 0
5 Chauvet 230SR User manual Landscape Lighting 12
6 Chauvet 18VW User manual Landscape Lighting 1
7 Chauvet 38 User manual Landscape Lighting 1
8 Chauvet 3030504 User manual Landscape Lighting 1
9 Chauvet 2100 User manual Landscape Lighting 1
10 Chauvet 412 User manual Landscape Lighting 0
11 Chauvet 4 User manual Landscape Lighting 1
12 Chauvet 412VW User manual Landscape Lighting 0
13 Chauvet 460-LED User manual Landscape Lighting 1
14 Chauvet 56 User manual Landscape Lighting 1
15 Chauvet 595 User manual Landscape Lighting 1
16 AeroGarden 300417AA User manual Landscape Lighting 14
17 Acoustic Research AW851 User manual Landscape Lighting 1
18 ADIC 5.1 User manual Landscape Lighting 0
19 American DJ 750W User manual Landscape Lighting 1
20 Allmand Allmond Nite-Lite Pro Vertical Tower V Series User manual Landscape Lighting 16