Agilent Technologies E4350B user manual

User manual for the device Agilent Technologies E4350B

Device: Agilent Technologies E4350B
Category: Landscape Lighting
Manufacturer: Agilent Technologies
Size: 0.98 MB
Added : 1/30/2014
Number of pages: 57
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Agilent Technologies E4350B. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Agilent Technologies E4350B.

For your convenience

If looking through the Agilent Technologies E4350B user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Agilent Technologies E4350B on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Agilent Technologies E4350B to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Agilent Technologies E4350B User manual - Online PDF
Advertisement
« Page 1 of 57 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Agilent Technologies E4350B but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Agilent Technologies E4350B. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Addendum A - SERVICE MANUAL
Agilent Technologies Model E4350B and E4351B Solar Array Simulators - P/N 5962-8233
For units with serial numbers:
E4350B US37410101 and up
E4351B US37430101 and up
Foreword
This addendum contains information for troubleshooting and repairing the Agilent E4350B and E4351B
Solar Array Simulators. The standard Service Manual for the Agilent Series 665xA DC Power Supplies (P/N
5959-3376), together with this Service Addendum, is shipped with the Solar Array Simulators whe

Summary of the content on the page No. 2

Table of Contents Addendum A - SERVICE MANUAL................................................................................................................................1 Foreword ........................................................................................................................................................................1 Areas of Difference ..............................................................................................................................

Summary of the content on the page No. 3

Chapter 1 Differences Firmware Revisions The Agilent E4350B/E4351B SAS firmware resides in the front panel board’s ROM chip (A3U4), the GPIB board’s ROM chip (A2U106), and in the DSP board’s ROM chips (A5U734 and A5U735). Use the *IDN query as described in chapter 3 of the Service Manual to get the firmware revision numbers. Chapter 2 Differences Test Equipment Required Table 2-2. Test Equipment Required for Verification Type Required Characteristics Recommended Model Current Monitor Resistor 15

Summary of the content on the page No. 4

Measurement Techniques Note All tests are performed in the FIXED as shown in Figure 2-1. • Measure the DC voltage directly at the +S and -S terminals. • Set the SENSE switch at the back of the supply to the Remote position. • Connect the remote sensing leads from +OUT to +S, and from -OUT to -S. • Use adequate wire gauge for the load leads as described in Chapter 4 of the Operating Manual. Basic Test Setup TO OSCILLOSCOPE OR RMS VOLTMETER IP VP IM IM I P S S +240 VDC MAX SET TO - + - + - + - REM

Summary of the content on the page No. 5

Voltage and Current Values Table 2-3. Voltage and Current Values Agilent Model Full-scale Max. Prog. Full-scale Max. Prog. Max. Prog. Voltage Voltage Current Current Overvoltage E4350B 60V 61.5V 8A 8.16A 73.0V E4351B 120V 123V 4A 4.08A 140V Transient Recovery Time This test does not need to be performed on the Agilent E4350B. CC RMS Noise Measurement Test Setup IP VP IM IM I P S S I +240 VDC MAX SET TO - - + - + - + - REMOTE LOCAL REMOTE MONITOR RMS RESISTOR 1.6 OHM VOLTMETER (Adjusted to 1 Ohm

Summary of the content on the page No. 6

Performance Test Record Table 2-15A. Performance Test Record for Agilent Model E4350B Agilent E4350B Report No.______________ Date _________________ Test Description Minimum Spec. Result * Maximum Spec. Measurement Uncertainty Constant Voltage Tests Voltage Programming and Readback Accuracy Low Voltage (set to 0V) V -10mV _________ mV +10mV 1.5μV out1 Readback Accuracy V – 42mV _________ mV V + 42mV 2μV out1 out1 High Voltage (set to 60V) V 59.945V __________ V 60.055V 845μV out2 Rea

Summary of the content on the page No. 7

Table 2-15B. Performance Test Record for Agilent Model E4351B Agilent E4351B Report No.______________ Date _________________ Test Description Minimum Spec. Result * Maximum Spec. Measurement Uncertainty Constant Voltage Tests Voltage Programming and Readback Accuracy Low Voltage (set to 0V) V -20mV _________ mV +20mV 1.7μV out1 Readback Accuracy V – 84mV _________ mV V + 84mV 1.7μV out1 out1 High Voltage (set to 120V) V 119.89V __________ V 120.11V 1.7mV out2 Readback Accuracy V –

Summary of the content on the page No. 8

Chapter 3 Differences Signature Analysis Signature analysis (SA) troubleshooting for the secondary circuits on the A1 main circuit board is ++NOT++ available for the Agilent E4350B unit. However, GPIB and front panel signature analysis is available as described in chapter 3 of the Service Manual. Self-Test Error Codes/Messages Table 3-2. Self-Test Error Codes/Messages Code/Message Description Probable Cause E1 FP RAM Front panel RAM test failed Microprocessor A3U3 defective E2 FP ROM Front pan

Summary of the content on the page No. 9

Overall Troubleshooting (sheet 1) Start "Overall Troubleshooting" Turn off supply, disconnect the load and push the sense switch on the rear panel in (local). Turn on the supply 1. Check ac input and line cord 2. Check line fuse 3. Turn off supply, remove top cover, check line Display On? No Fan On? No voltage select jumpers on T1. 4. Turn on supply, check ac power and ac bias voltages at T1 secondary Yes Yes Go to "No Display" Troubleshooting Turn off the supply and remove top cover to access

Summary of the content on the page No. 10

Overall Troubleshooting (sheet 2) From Sheet 1 A Check cables from A1 Voltage display No No A5J722-1 (Vmon) No main board to A5 DSP Reads approx. right within spec approx. 4.1V board. but outside spec ? ? ? Yes Yes Yes Calibrate the supply. See Voltage readback circuit on Appendix A in the Operating A5 DSP board defective. manual. CV See CV/CC Status Annunciator No Annunciator Troubleshooting" paragraph on ? Yes Turn off the supply and connect a short across the output terminals. Turn on and p

Summary of the content on the page No. 11

Overall Troubleshooting (sheet 3) D From Sheet 3 Turn off the supply and remove the short from the output. Turn on and program output voltage and current to full scale and the OV to zero using front panel keys. Check that the supply goes into OV condition (OV Prot annunciator on and output at 0) Go to "OV Will Not Fire" Did OV occur? No Troubleshooting Yes Turn off the supply and connect a GPIB controller to the supply. Turn on the supply and using the controller, program the supply to full scal

Summary of the content on the page No. 12

Overall Troubleshooting – sheet 4 C B From Sheet 1 From Sheet 2 Output voltage Output current Calibrate the supply. See Appendix approx. right but approx. right but Yes Yes A in the Operating manual. outside spec outside spec ? ? No PROT Display reads Check Voltage Monitor No No annumciator on approx. output circuit A1U605 ? voltage ? No Yes Yes Press PROT key Display reads Check output for No Output shorted Yes approx. 0 Amps shorted circuits ? ? No Check Current Monitor Display reads No circui

Summary of the content on the page No. 13

Overall Troubleshooting (sheet 5) E From Sheet 4 Programmable OCP tripped, Check OV & OC OC circuits A1U405, U411, Imon Yes displayed amp A1U403 and OC_PROG signal ? at A5J722-26 (TP41) No Go to "OV at Turn-On" OV Yes troubleshooting. displayed ? No Check if OCP is enabled at turn-on OC Yes and current is programmed to zero. displayed Check current circuit. ? No RI (Remote Inhibit) displayed? Check for short between A2TB101 and ground. Figure 3-2. Overall Troubleshooting (sheet 5 of 5) Flow Cha

Summary of the content on the page No. 14

No Display Troubleshooting "No Display" Start Turn on the supply and try to program it from the front panel. While measuring the voltage at the output terminals, program the voltage and current to full scale. Toggle the ON/OFF key while observing the external voltmeter. Check the A2 GPIB board, bias circuits, No display but output No PCLR (test points 1 - 4 Table 6-3) and OK cable W9 ? Yes Turn off supply, remove front panel assembly to access circuits on the A3 front panel board. Turn on the su

Summary of the content on the page No. 15

OV Will Not Fire Troubleshooting "OV Will Not Fire" Start Turn off supply and remove top cover. Turn on and check secondary bias and reference voltages. (Test Points 9 through 17, Table 6-3) Troubleshoot the appropriate Voltages OK No defective circuit. ? Yes Program voltage and current to full scale and OV to 1/2 full scale. Check voltage at A5 J722- 22 (TP40), A1U405 and A1U602 with respect to common (TP9). J722-22 approx. 2.7V No Replace A5 DSP board ? Check voltage at A1U405-5 with respect t

Summary of the content on the page No. 16

OV at Turn-On Troubleshooting "OV at Turn-On" Start Caution: During Check that the supply is not programmed to OV at turn-on. Ensure that the voltage setting is not greater these tests, the than the OV setting. Program 0V and Max. OV, then save the settings in Register 0 (press shift, save, 0 output may be at and Enter key). Turn the supply off then back on. hazardous levels. Connect a DC coupled scope across the output terminals. Turn the supply on and check that the output does not momentarily

Summary of the content on the page No. 17

Output Held Low Troubleshooting (sheet 1) "Output Held Low" Start Caution: During The supply’s output is low and the PROT annunciator is not on. Turn supply off, disconnect these tests, the the load and remove the top cover. Turn the supply output may be at on and check the secondary bias and reference voltages (TP’s 9 through 12 See Table 6-3). hazardous levels. Troubleshoot the defective Voltages OK No curcuit. See Fig. 6-5 Sheet 1. ? Yes Check that the +Rail and -Rail Voltages are correct. S

Summary of the content on the page No. 18

Output Held Low Troubleshooting (sheet 2) From Sheet 1 A No Check IMon voltage at A1U403-7 A1D413 Conducting Yes (TP28) to common (TP9). ? Yes A1D413 Conducting Yes CC Comparator A1U403 defective. Check voltage at A1U408-3 and ? R686 (TP36) to common (TP9). No IMon Amp A1U403 defective. Gross Current Limit circuit A12U409 A1U408-3 Neg Yes defective. ? No Check A1U408, D420, loading of A1R638 > 12mV No voltage by Tunnel Circuits. ? Yes Disconnect cables from tunnel boards A4A1-A4A4 one at a time

Summary of the content on the page No. 19

Output Held High Troubleshooting "Output Held High" Start Caution: During these tests, the Turn supply off and remove the top cover. Disable output may be at the Overvoltage circuit by shorting A1U410 pins1 & 2 and lifting A1R447. Turn the supply on and check hazardous levels. the secondary bias and reference voltages (TP’s 9 through 12 See Table 6-3). Troubleshoot the defective Voltages OK No curcuit. See Fig. 6-5 Sheet 1. ? Yes Program voltage and current to 1/2 full scale. Check voltage at A5

Summary of the content on the page No. 20

Initialization and Factory Preset Replacement Program Listing (sheet 1) 10 ! Program to initialize EEPROM data in Models E4350B and E4351B 20 ! RE-STORE "INIT_435X" 30 ! Rev A.00.00 dated Nov, 17,1998 40 ! 50 DIM Init_data(1:49),Model$[6],Idn$[21] 60 INTEGER Addr(1:49),Length(1:49) 70 ASSIGN @Ps TO 705 ! Supply must be at address 705 80 CLEAR SCREEN 90 ! 100 Eprom_data_addr: ! Data address 110 DATA 2,6,10,14,18,19,20,24,28,32


Alternative user manuals
# User manual Category Download
1 Agilent Technologies E4350B User manual Water Heater 0
2 Agilent Technologies E4351B User manual Landscape Lighting 3
3 AeroGarden 300417AA User manual Landscape Lighting 14
4 Acoustic Research AW851 User manual Landscape Lighting 1
5 ADIC 5.1 User manual Landscape Lighting 0
6 American DJ 750W User manual Landscape Lighting 1
7 Allmand Allmond Nite-Lite Pro Vertical Tower V Series User manual Landscape Lighting 16
8 AT&T AT3111-2 User manual Landscape Lighting 0
9 ARRI max 12 User manual Landscape Lighting 1
10 ARRI max 18 User manual Landscape Lighting 10
11 Agilent Technologies E4351B User manual Landscape Lighting 3
12 ARRI Studio Ceramic 250 User manual Landscape Lighting 3
13 American DJ S-150/DMX User manual Landscape Lighting 1
14 ATD Tools ATD-80113 User manual Landscape Lighting 0
15 Blue Rhino Endless Summer GTL7179SP User manual Landscape Lighting 0