Summary of the content on the page No. 1
Order No. MAC0801088C2
Air Conditioner
Indoor Unit Outdoor Unit
CS-CE7HKEW CU-CE7HKE
CS-CE9HKEW CU-CE9HKE
CS-CE12HKEW CU-CE12HKE
Please file and use this manual together with the service manual for Model No. CU-2E18CBPG, CU-3E23CBPG, CU-
4E27CBPG, Order No. RAC0209005C2, Model No. CU-3E18EBE, Order No. RAC0503011C2 and Model No. CU-2E15GBE,
Order No. MAC0704001A2.
TABLE OF CONTENTS
PAGE PAGE
1 Safety Precautions----------------------------------------------- 2 4.2. Outdoor Unit--------------
Summary of the content on the page No. 2
9.2. Outdoor Unit----------------------------------------------- 26 13.1. Protection Control For All Operations -------------- 47 10 Printed Circuit Board ------------------------------------------ 27 13.2. Protection Control For Cooling & Soft Dry 10.1. Indoor Unit ------------------------------------------------- 27 Operation -------------------------------------------------- 49 10.2. Outdoor Unit----------------------------------------------- 29 13.3. Protection Control For Heating Operation-
Summary of the content on the page No. 3
6. This equipment is strongly recommended to install with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation breakdown. 7. Use the specified cable and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection. 8. Wire
Summary of the content on the page No. 4
2 Specifications 2.1. CS-CE7HKEW CU-CE7HKE ITEM UNIT INDOOR UNIT OUTDOOR UNIT Performance Test Condition EUROVENT kW 2.05 (0.70 ~ 2.40) C Capacity O kCal/h 1760 (600 ~ 2060) O W/W 4.36 (4.12 ~ 4.14) L EER kCal/hW 3.74 (3.53 ~ 3.55) I N dB (A) High 37, Low 24, QLo 20 High 45 Noise Level G Power level dB High 48, Low 35, QLo 31 58 kW 2.80 (0.70 ~ 4.00) H Capacity E kCal/h 2410 (600 ~ 3440) A W/W 4.41 (4.38 ~ 3.92) T COP kCal/hW 3.80 (3.75 ~ 3.37) I dB (A) High 38, Low 25, QLo 22 High 46 N Noise L
Summary of the content on the page No. 5
ITEM UNIT INDOOR UNIT OUTDOOR UNIT Type Cross-Flow Fan Propeller Fan Material ASG20K1 PP Motor Type Transistor (8-pole) Induction (6-pole) Input Power W — 62 Output Power W 30 25 Fan QLo (Cool/Heat) rpm 680 / 780 — Lo (Cool/Heat) rpm 780 / 850 — Fan Speed Me (Cool/Heat) rpm 1010 / 1085 — Hi (Cool/Heat) rpm 1240 / 1320 750 / - SHi (Cool/Heat) rpm 1310 /1390 — Fin Material Aluminium (Pre Coat) Aluminium Fin Type Slit Fin Corrugated Fin Heat Exchanger Row x Stage x FPI 2 x 15 x 17 2 x 24 x 17 36.4
Summary of the content on the page No. 6
2.2. CS-CE9HKEW CU-CE9HKE ITEM UNIT INDOOR UNIT OUTDOOR UNIT Performance Test Condition EUROVENT kW 2.60 (0.80 ~ 3.00) C Capacity O kCal/h 2240 (690 ~ 2580) O W/W 4.41 (4.57 ~ 4.00) L EER kCal/hW 3.80 (3.94 ~ 3.44) I N dB (A) High 39, Low 25, QLo 20 High 46 Noise Level G Power level dB High 50, Low 36, QLo 31 59 kW 3.60 (0.80 ~ 5.00) H Capacity E kCal/h 3100 (690 ~ 4300) A W/W 4.31 (4.85 ~ 3.73) T COP kCal/hW 3.71 (4.18 ~ 3.21) I N dB (A) High 40, Low 27, QLo 24 High 47 Noise Level G Power leve
Summary of the content on the page No. 7
ITEM UNIT INDOOR UNIT OUTDOOR UNIT Type Cross-Flow Fan Propeller Fan Material ASG20K1 PP Motor Type Transistor (8-pole) Induction (6-pole) Input Power W — 65 Output Power W 30 25 Fan QLo (Cool/Heat) rpm 720 / 890 — Lo (Cool/Heat) rpm 830 / 940 — Fan Speed Me (Cool/Heat) rpm 1070 / 1170 — Hi (Cool/Heat) rpm 1310 / 1400 770 / - SHi (Cool/Heat) rpm 1390 / 1490 — Fin Material Aluminium (Pre Coat) Aluminium Fin Type Slit Fin Corrugated Fin Heat Exchanger Row x Stage x FPI 2 x 15 x 19 2 x 24 x 17 36.4
Summary of the content on the page No. 8
2.3. CS-CE12HKEW CU-CE12HKE ITEM UNIT INDOOR UNIT OUTDOOR UNIT Performance Test Condition EUROVENT kW 3.50 (0.80 ~ 4.00) C Capacity O kCal/h 3010 (690 ~ 3440) O W/W 3.83 (4.32 ~ 3.39) L EER kCal/hW 3.29 (3.73 ~ 2.92) I N dB (A) High 42, Low 28, QLo 20 High 48 Noise Level G Power level dB High 53, Low 39, QLo 31 61 kW 4.80 (0.80 ~ 6.50) H Capacity E kCal/h 4130 (690 ~ 5590) A W/W 3.81 (4.57 ~ 3.44) T COP kCal/hW 3.28 (3.94 ~ 2.96) I N dB (A) High 42, Low 33, QLo 30 High 50 Noise Level G Power le
Summary of the content on the page No. 9
ITEM UNIT INDOOR UNIT OUTDOOR UNIT Type Cross-Flow Fan Propeller Fan Material ASG20K1 PP Motor Type Transistor (8-pole) Induction (6-pole) Input Power W — 70 Output Power W 30 30 Fan QLo (Cool/Heat) rpm 730 / 1090 — Lo (Cool/Heat) rpm 920 / 1150 — Fan Speed Me (Cool/Heat) rpm 1175 / 1325 — Hi (Cool/Heat) rpm 1430 / 1500 830 / - SHi (Cool/Heat) rpm 1500 / 1550 — Fin Material Aluminium (Pre Coat) Aluminium Fin Type Slit Fin Corrugated Fin Heat Exchanger Row x Stage x FPI 2 x 15 x 21 2 x 24 x 17 36
Summary of the content on the page No. 10
2.4. Outdoor Unit: CU-2E15GBE 10
Summary of the content on the page No. 11
2.5. Outdoor Unit: CU-3E18EBE 11
Summary of the content on the page No. 12
2.6. Outdoor Unit: CU-3E23CBPG CU-4E27CBPG 12
Summary of the content on the page No. 13
13
Summary of the content on the page No. 14
14
Summary of the content on the page No. 15
15
Summary of the content on the page No. 16
3Features • Inverter Technology - Wider output power range - Energy saving - Quick Cooling -Quick Heating - More precise temperature control • E-ion Air Purifying System with Patrol Sensor - Active e-ions are released to catch dust particles and bring them back the large positively charged filter • Environment Protection - Non-ozone depletion substances refrigerant (R410A) • Long Installation Piping - CS/CU-CE7/9/12HK, long piping up to 15 meters • Easy to use remote control • Quality Improvemen
Summary of the content on the page No. 17
• Multi Split Combination Possibility: - A single outdoor unit enables air conditioning of up to two separate rooms for CU-2E15GBE, CU-2E18CBPG. - A single outdoor unit enables air conditioning of up to three separate rooms for CU-3E18EBE, CU-3E23CBPG. - A single outdoor unit enables air conditioning of up to four separate rooms for CU-4E27CBPG. 17
Summary of the content on the page No. 18
4 Location of Controls and Components 4.1. Indoor Unit 4.2. Outdoor Unit 4.3. Remote Control 18
Summary of the content on the page No. 19
5 Dimensions 5.1. Indoor Unit 19
Summary of the content on the page No. 20
5.2. Outdoor Unit 20