Order No. PHAAM0905053C2
Air Conditioner
Indoor Unit Outdoor Unit
CS-CE9JKE CU-CE9JKE
CS-CE12JKE CU-CE12JKE
TABLE OF CONTENTS
PAGE PAGE
1 Safety Precautions----------------------------------------------- 3 9.1. Indoor Unit ------------------------------------------------- 19
2 Specifications ----------------------------------------------------- 5 9.2. Outdoor Unit----------------------------------------------- 20
3Features ------------------------------------------------------------11 10 Printed
Summary of the content on the page No. 2
12.7. Indication Panel------------------------------------------- 33 13 Protection Control ---------------------------------------------- 34 13.1. Protection Control For All Operations--------------- 34 13.2. Protection Control For Cooling & Soft Dry Operation--------------------------------------------------- 36 13.3. Protection Control For Heating Operation --------- 37 14 Servicing Mode -------------------------------------------------- 38 14.1. Auto OFF/ON Button ----------------------------
Summary of the content on the page No. 3
1 Safety Precautions • Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. � Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed. � The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction wil
Summary of the content on the page No. 4
18. For R410A models, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same may cause abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A materials. Thickness of copper pipes used with R410A must be more than 0.8mm. Never use copper pipes thinner than 0.8mm. It is desirable that the amount of residual oil is less than 40 mg/10m. 19. During installation, install the refrigerant piping
Summary of the content on the page No. 5
2 Specifications INDOOR CS-CE9JKE MODEL OUTDOOR CU-CE9JKE Performance Test Condition EUROVENT Phase, Hz Single, 50 Power Supply V 230 Min. Mid. Max. kW 0.60 2.60 3.00 Capacity BTU/h — — — Kcal/h 520 2240 2580 Running Current A — 2.8 — Input Power W 125 590 750 Annual Consumption kWh — 295 — W/W 4.80 4.41 4.00 EER Kcal/hW 4.16 3.80 3.44 Power Factor % — 92 — dB-A 39 / 25 Indoor Noise (H / L) Power Level dB 55 / 42 dB-A 46 / - Outdoor Noise (H / L) Power Level dB 61 / - kW 0.60 3.60 5.00 Capacity
Summary of the content on the page No. 6
INDOOR CS-CE9JKE MODEL OUTDOOR CU-CE9JKE Type Propeller Fan Material PP Motor Type DC Type (8-poles) Input Power W — Output Power W 40 Cool rpm 800 Speed Hi Heat rpm 790 Moisture Removal L/h (Pt/h) 1.6 (3.4) 3 3 Cool/Fan 5.4 (190) m /min (ft /min) Lo 3 3 Heat 6.4 (230) m /min (ft /min) 3 3 Cool/Fan 8.0 (280) m /min (ft /min) Indoor Airflow Me 3 3 Heat 9.3 (330) m /min (ft /min) 3 3 Cool/Fan 11.3 (400) m /min (ft /min) Hi 3 3 Heat 11.9 (420) m /min (ft /min) 3 3 Cool 29.8 (1050) m /min (ft /min)
Summary of the content on the page No. 7
INDOOR CS-CE9JKE MODEL OUTDOOR CU-CE9JKE Dry Bulb Wet Bulb Maximum 32 23 Cooling Minimum 16 11 Indoor Operation Range Maximum 30 — Heating Minimum 16 — Maximum 43 26 Cooling Minimum 16 11 Outdoor Operation Range Maximum 24 18 Heating Minimum -15 -6 1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 2. Heating capacities are based o
Summary of the content on the page No. 8
INDOOR CS-CE12JKE MODEL OUTDOOR CU-CE12JKE Performance Test Condition EUROVENT Phase, Hz Single, 50 Power Supply V 230 Min. Mid. Max. kW 0.60 3.50 4.00 Capacity BTU/h — — — Kcal/h 520 3010 3440 Running Current A — 4.4 — Input Power W 125 915 1.18k Annual Consumption kWh — 458 — W/W 4.80 3.83 3.39 EER Kcal/hW 4.16 3.29 2.92 Power Factor % — 90 — dB-A 42 / 28 Indoor Noise (H / L) Power Level dB 58 / 45 dB-A 48 / - Outdoor Noise (H / L) Power Level dB 63 / - kW 0.60 4.80 6.50 Capacity BTU/h — — — K
Summary of the content on the page No. 9
INDOOR CS-CE12JKE MODEL OUTDOOR CU-CE12JKE Type Propeller Fan Material PP Motor Type DC Type (8-poles) Input Power W — Output Power W 40 Cool rpm 840 Speed Hi Heat rpm 820 Moisture Removal L/h (Pt/h) 2.0 (4.2) 3 3 Cool/Fan 6.3 (220) m /min (ft /min) Lo 3 3 Heat 9.4 (332) m /min (ft /min) 3 3 Cool/Fan 8.5 (300) m /min (ft /min) Indoor Airflow Me 3 3 Heat 11.0 (389) m /min (ft /min) 3 3 Cool/Fan 12.5 (440) m /min (ft /min) Hi 3 3 Heat 12.8 (450) m /min (ft /min) 3 3 Cool 31.0 (1090) m /min (ft /mi
Summary of the content on the page No. 10
INDOOR CS-CE12JKE MODEL OUTDOOR CU-CE12JKE Dry Bulb Wet Bulb Maximum 32 23 Cooling Minimum 16 11 Indoor Operation Range Maximum 30 — Heating Minimum 16 — Maximum 43 26 Cooling Minimum 16 11 Outdoor Operation Range Maximum 24 18 Heating Minimum -15 -6 1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 2. Heating capacities are based
Summary of the content on the page No. 11
3 Features • Inverter Technology - Wider output power range - Energy saving - More precise temperature control � Environment Protection - Non-ozone depletion substances refrigerant (R410A) � Long Installation Piping - Long piping up to 15 meters during single split connection only � Easy to use remote control � Quality Improvement - Random auto restart after power failure for safety restart operation - Gas leakage protection - Prevent compressor reverse cycle - Inner protector to protect Compres
Summary of the content on the page No. 12
4 Location of Controls and Components 4.1. Indoor Unit 4.2. Outdoor Unit 4.3. Remote Control 12
Summary of the content on the page No. 13
5 Dimensions 5.1. Indoor Unit 13
Summary of the content on the page No. 14
5.2. Outdoor Unit 14
Summary of the content on the page No. 15
6 Refrigeration Cycle Diagram 15
Summary of the content on the page No. 16
7 Block Diagram 16
Summary of the content on the page No. 17
8 Wiring Connection Diagram 8.1. Indoor Unit 17
Summary of the content on the page No. 18
8.2. Outdoor Unit 18
Summary of the content on the page No. 19
9 Electronic Circuit Diagram 9.1. Indoor Unit 19
Summary of the content on the page No. 20
9.2. Outdoor Unit 20