Honda Power Equipment EX2200 user manual

User manual for the device Honda Power Equipment EX2200

Device: Honda Power Equipment EX2200
Category: Portable Generator
Manufacturer: Honda Power Equipment
Size: 1.37 MB
Added : 3/28/2014
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honda Power Equipment EX2200. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honda Power Equipment EX2200.

For your convenience

If looking through the Honda Power Equipment EX2200 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honda Power Equipment EX2200 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honda Power Equipment EX2200 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honda Power Equipment EX2200 User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honda Power Equipment EX2200 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honda Power Equipment EX2200. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Summary of the content on the page No. 2

m The generator is a potential source of electrical shock if misused. Do not-&pose the generator to moisture, rain or snow. Do not let the generator get wet, and do not operate it with wet hands.,

Summary of the content on the page No. 3

Thank you for purchasing a Honda generator. This manual covers operation and maintenance of the EX2200 generator. All information in this publication is based on the latest product information available at the time of approval for printing. Honda Motor Co., Ltd. reserves the right to make changes at any time without notice and without incurring any obligation. No part of this publication may be reproduced without written permission. This manual should be considered a permanent part of the

Summary of the content on the page No. 4

CONTENTS CONTENTS 1. GENERATOR SAFETY.. ............................................................ 3 2. CAUTION LABEL LOCATION.. ................................................. 4 i.. ..... 6 3. COMPONENT IDENTIFICATION.. ..................................... 8 4. PRE-OPERATION CHECK.. ...................................................... 5. STARTING THE ENGINE ......................................................... 11 6. GENERATOR USE ............................................

Summary of the content on the page No. 5

1. GENERATOR SAFETY mm To ensure safe operation- l Place the generator at least 1 m (3 ft) away from buildings or other equipment during operation. l Operate the generator on a level surface. If the generator is tilted, fuel spillage may result. l Exhaust gas contains poisonous carbon monoxide. Never run the generator in an enclosed area. Be sure to provide adequate ventilation. l Know how to stop the generator quickly and understand the operation of all controls. Never permit anyone

Summary of the content on the page No. 6

2. CAUTION LABEL LOCATION HOT l EXHAUST ECHAPPEMENT l CHAUD I

Summary of the content on the page No. 7

WARN’lNG DO NOT USE INDOORS. EXHAUST GAS CONTAINS’ POISONOUS CARBON MONOXIDE. . ,,JTI()N NE PAS UTILISER DANS UN ENDROIT FERME A CAUSE DU RISQUE D’EMPOISONNENT DU GAZ. 1 ATENCl()N RQUE EL 11 NO LO USE EN LUGARES CERRADOS POI _ MONOXIDE DE CARBON0 ES VENENOSO: I ICHECK FOR SPILLED FUEL OR FUEL LEAKS. STOP ENGINE BEFORE REFUELING. ..:.: 7 ,.:::::, .::g;:;::. .‘.::p;l::.’ :jjjj:. ..:::I ARRETER LE MOTEUR AVANT DE REFAIRE LE PLEIN . . . . ,. ,. “C ‘.., :j:; .:: IINSPECCIONAR P

Summary of the content on the page No. 8

3. COMPONENT IDENTIFICATION VOLTAGE ADJUSTMENT KNOB AC RECEPTACLES CHOKE KNOB - ENGINE SWITCH llnterlocked with fuel valve) OIL ALERT LAMP STARTER GRIP- DAMPER RUBBER TERMINAL ----------- - OIL FILLER CAP L FRONT MAINTENANCE COVER 6

Summary of the content on the page No. 9

FUEL TANK SPARK CAP PLUG UPPER MAINTENANCE COVER 7 AIR CLEANER REAR MAINTENANCE COVER OIL DRAIN BOLT 1 7

Summary of the content on the page No. 10

4. PRE-OPERATION CHECK CAUTION: Be sure to check the generator on a level surface with the engine stopped. 1. Check the engine oil level. CAUTION: Engine oil is a major factor affecting engine performance and service life. Non-detergent or vegetable oils are not recommended. Use Honda 4-stroke oil, or an equivalent high detergent, premium quality motor oil certified to meet or exceed U.S. automobile manufacturers’ re- quirements for Service Classification SG, SF/CC, CD. Motor oils classi

Summary of the content on the page No. 11

2. Check the fuel level. Check the fuel gauge and refill the tank if the fuel level is low. Your engine is designed to use any gasoline that has a pump octane number (v) of 86 or higher, or that has a research octane number of 91 or higher. Gasoline pumps at service station normally display the pump octane number. We recommend that you use unleaded fuel because it produces fewer engine and spark plug deposits and extends the life of exhaust system components.. . Never use stale or conta

Summary of the content on the page No. 12

l Gasoline is extremely flammable and is explosive under certain conditions. l Refuel in a well-ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored. l Do not overfill the fuel tank (there should be no fuel in the filler neck). After refueling, make sure the tank cap is closed properly and securely. l Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may ignite. If any fu

Summary of the content on the page No. 13

5. STARTING THE ENGINE 1. Turn off the AC circuit breaker. , CIRCUIT BREAKER 2.Turn on the engine switch. ENGliE SWITCH 11

Summary of the content on the page No. 14

3. Pull the choke knob out to close. CHO/KE KNOB I II 4. Pull the starter rope lightly until resistance is felt, then pull briskly. CAUTION: l Do not allow the starter grip to snap back. Return it slowly by hand. l Do not let the starter rope rub against the generator body or the rope will wear out prematurely. NOTE: Make sure the pilot lamp comes on. If not, check the bulb filament. STARTER GRIP 12

Summary of the content on the page No. 15

5. Push the choke knob in as the engine warms up. CHOKE KNOB Oil Alert System Before the oil level in the crankcase can fall below a safe limit, the Oil Alert System will automatically shut off the engine. The Oil Alert Lamp will light when the recoil starter grip is pulled. To restart, add enough recommended engine oil to bring the oil level to the upper level mark on the dipstick (See page 81, and restart the engine. OIL ALERT LAMP ENGINE SWITCH NOTE: The engine switch will remain

Summary of the content on the page No. 16

6. GENERATOR USE l To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a length of heavy wire between the ground ter- minal and an external ground source. l Connections for standby power to a building’s electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to backfeed into the utility lines. Such backfeed may ele

Summary of the content on the page No. 17

AC applications 1. Start the engine and make sure the pilot lamp comes on. If not, check the filament. 2. Switch on the AC Circuit Breaker. NOTE: Although voltage adjustment is usually not required, fine ad- justments may be made by turning the voltage adjustment knob. Use the generator at the specified voltage (12OV). 3. Plug in the appliance; always use three-pronged plugs. CAUTION: Be sure that appliances do not exceed the generator’s rated load capacity for more than 30 minutes and

Summary of the content on the page No. 18

DC application ’ The DC terminals may be used for charging 12 volt automotive-type batteries only. l The battery gives off explosive gases; keep sparks, flames and cigarettes away. Provide adequate ventilation when charging or using batteries in an enclosed space. l The battery contains sulfuric acid (electrolyte). Contact with skin or eyes may cause severe burns. Wear protective clothing and a face shield. - If electrolyte gets on your skin, flush with water. -If electrolyte gets in y

Summary of the content on the page No. 19

7. STOPPING THE ENGINE To stop the engine in an emergency, turn the engine switch OFF. 1 .Turn off the AC circuit breaker. .AC CIRCUIT BREAKER 2.Turn off the engine switch. I ENGINE SWITCH I I 17

Summary of the content on the page No. 20

8. MAINTENANCE The purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition. Inspect or service as scheduled in the table on the next page. cmml Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated. The exhaust con- tains poisonous carbon monoxide gas. CAUTION: Use genuine HONDA parts or their equivalent. The use of replacement parts which are not of equivalent quality ma


Alternative user manuals
# User manual Category Download
1 Honda Power Equipment Companion 31Z07701 User manual Portable Generator 13
2 Honda Power Equipment E3500 User manual Portable Generator 73
3 Honda Power Equipment E300 User manual Portable Generator 866
4 Honda Power Equipment E1000 User manual Portable Generator 72
5 Honda Power Equipment DCX3000 User manual Portable Generator 29
6 Honda Power Equipment EB11000 User manual Portable Generator 30
7 Honda Power Equipment E900 User manual Portable Generator 9
8 Honda Power Equipment E4500 User manual Portable Generator 50
9 Honda Power Equipment E1500 User manual Portable Generator 245
10 Honda Power Equipment EB12D User manual Portable Generator 55
11 Honda Power Equipment EB2200X User manual Portable Generator 41
12 Honda Power Equipment EB2500X User manual Portable Generator 13
13 Honda Power Equipment EB3000c User manual Portable Generator 31
14 Honda Power Equipment EB3500X User manual Portable Generator 34
15 Honda Power Equipment EB4000 User manual Portable Generator 4
16 ACDelco AC-G0005 User manual Portable Generator 1
17 ACDelco AC-G0002 User manual Portable Generator 0
18 ACDelco AC-G0004 User manual Portable Generator 3
19 AEG 2.33 2 User manual Portable Generator 3
20 ACDelco AC-G0003 User manual Portable Generator 0