Summary of the content on the page No. 1
Black DIC F101
00X31-Z07-7010 EU2000i
Owner’s Manual
GENERATOR
EU2000i
See page 79 for
31Z07701 2eY15000.2009.03
Initial Use Instructions
00X31-Z07-7010 Printed in Japan o2008-2009 Honda Motor Co., Ltd. -All Rights Reserved
Summary of the content on the page No. 2
09/02/17 17:12:59 31Z07700_001 The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas. Breathing carbon monoxide can cause unconsciousness or death. Never run the generator in a closed, or even partly closed area where people may be present. Keep this owner’s manual handy so that you can refer to it at an
Summary of the content on the page No. 3
09/02/17 17:13:05 31Z07700_002 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely. This manual contains all the information on how to do that; please read it carefully. As you read this manual, you will find information preceded by a symbol. That information is intended to help you avoid da
Summary of the content on the page No. 4
09/02/17 17:13:14 31Z07700_003 A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual. This information alerts you to potential hazards that could hurt you or others. Of course, it is not practical or possible to warn you about all the hazards associated with operating
Summary of the content on the page No. 5
09/02/17 17:13:17 31Z07700_004 CONTENTS GENERATOR SAFETY.................................................................................6 IMPORTANT SAFETY INFORMATION ...................................................6 Operator Responsibility.......................................................................6 Carbon Monoxide Hazards..................................................................6 Electric Shock Hazards .....................................................................
Summary of the content on the page No. 6
09/02/17 17:13:21 31Z07700_005 CONTENTS OPERATION ...............................................................................................22 SAFE OPERATING PRECAUTIONS ......................................................22 STARTING THE ENGINE .......................................................................23 STOPPING THE ENGINE .......................................................................26 AC OPERATION....................................................................
Summary of the content on the page No. 7
09/02/17 17:13:24 31Z07700_006 CONTENTS TRANSPORTING .......................................................................................60 TAKING CARE OF UNEXPECTED PROBLEMS........................................61 ENGINE WILL NOT START....................................................................61 ENGINE LACKS POWER........................................................................62 NO POWER AT THE RECEPTACLES.....................................................63 TECHNICAL &
Summary of the content on the page No. 8
09/02/17 17:13:30 31Z07700_007 GENERATOR SAFETY IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all instructions in this manual and on the generator. The most common hazards are discussed below, along with the best way to protect yourself and others. Operato
Summary of the content on the page No. 9
09/02/17 17:13:39 31Z07700_008 GENERATOR SAFETY Electric Shock Hazards The generator produces enough electric power to cause a serious shock or electrocution if misused. Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator dry. If the generator is stored outdoors, unprotected from the weather, check all of the electrical components on the control panel b
Summary of the content on the page No. 10
09/02/17 17:13:42 31Z07700_009 GENERATOR SAFETY Refuel With Care Gasoline is extremely flammable, and gasoline vapor can explode. Allow the engine to cool if the generator has been in operation. Refuel only outdoors in a well-ventilated area with the engine OFF. Do not overfill the fuel tank. Never smoke near gasoline, and keep other flames and sparks away. Always store gasoline in an approved container. Make sure that any spilled fuel has been wiped up before starting the engine. 8
Summary of the content on the page No. 11
09/02/17 17:13:56 31Z07700_010 GENERATOR SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda servicing dealer for a replacement. California type Non-California type 9
Summary of the content on the page No. 12
09/02/17 17:14:01 31Z07700_011 GENERATOR SAFETY 10
Summary of the content on the page No. 13
09/02/17 17:14:07 31Z07700_012 CONTROLS & FEATURES COMPONENT & CONTROL LOCATIONS Use the two illustrations on these pages to locate and identify the most frequently used controls. PARALLEL OPERATION OUTLETS TM ECO-THROTTLE SWITCH 20A RECEPTACLE 30A twist lock receptacle OIL ALERT INDICATOR OVERLOAD INDICATOR AC CIRCUIT PROTECTOR OUTPUT INDICATOR GROUND TERMINAL CHOKE LEVER FUEL TANK CAP VENT LEVER FUEL TANK CAP MAINTENANCE COVER STARTER GRIP ENGINE SWITCH To obtain more than 1.6 kVA from the 3
Summary of the content on the page No. 14
09/02/17 17:14:11 31Z07700_013 CONTROLS & FEATURES SPARK PLUG MAINTENANCE COVER SPARK PLUG MUFFLER AIR CLEANER 12
Summary of the content on the page No. 15
09/02/17 17:14:19 31Z07700_014 CONTROLS & FEATURES CONTROLS Engine Switch ENGINE SWITCH The engine switch controls the O ON N ignition system and the fuel valve. OFF Stops the engine and closes the fuel valve. ON Running position; opens the fuel valve and allows the engine to be started. O OF FF F Starter Grip Pulling the starter grip operates the recoil starter to crank the engine. Do not allow the starter grip to STARTER GRIP snap back against the generator. Return it gently to prevent damag
Summary of the content on the page No. 16
09/02/17 17:14:27 31Z07700_015 CONTROLS & FEATURES Fuel Tank Cap Vent Lever The fuel tank cap is provided with a vent lever to seal the fuel tank. The vent lever must be in the ON position for the engine to run. When the engine is not in use, leave the vent lever in the OFF position to reduce the possibility of fuel leakage. Allow the engine to cool well before turning the vent lever to the OFF position. NON-CALIFORNIA TYPE CALIFORNIA TYPE O OF FF F O OF FF F O ON N O ON N FUEL TANK CAP FUEL TAN
Summary of the content on the page No. 17
09/02/17 17:14:35 31Z07700_016 CONTROLS & FEATURES TM Eco-Throttle Switch TM The Eco-Throttle system automatically reduces engine speed when loads are turned off or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load. If high electrical loads are connected simultaneously, turn the Eco-Throttle switch to the OFF position to reduce voltage changes. ON: Recommended to minimize fuel consumption and further reduce noise level
Summary of the content on the page No. 18
09/02/17 17:14:40 31Z07700_017 CONTROLS & FEATURES AC Circuit Protector The AC circuit protector will automatically switch OFF if there is a short circuit or a significant overload of the generator at the 20A receptacle. If the circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the circuit protector ON. 20A RECEPTACLE AC CIRCUIT PROTECTOR ON OFF PUSH AC CIRCUIT PROTECTOR 16
Summary of the content on the page No. 19
09/02/17 17:14:45 31Z07700_018 CONTROLS & FEATURES FEATURES Ground Terminal The generator ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle. Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator. GROUND TERMINAL 17
Summary of the content on the page No. 20
09/02/17 17:14:50 31Z07700_019 CONTROLS & FEATURES Output Indicator The output indicator (green) is illuminated when the generator is operating normally. It indicates that the generator is producing electrical power at the receptacles. OUTPUT INDICATOR (GREEN) Overload Indicator If the generator is overloaded (in excess of 2.0 kVA), or if there is a short circuit in a connected appliance, the overload indicator (red) will come ON. The overload indicator (red) will stay ON, and after about four s