Summary of the content on the page No. 1
2
Owner’s Guide
XPower Inverter
t: 1-800-670-0707 (toll-free)
f: 1-800-994-7828 (toll-free)
1200 PLUS
e: CustomerService@xantrex.com
www.xantrex.com
1750 PLUS
445-0145-01-01 Printed in China
Summary of the content on the page No. 2
About Xantrex Xantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to 1 MW utility-scale systems for wind, solar, batteries, fuel cells, microturbines, and backup power applications in both grid-connected and standalone systems. Xantrex products include inverters, battery chargers, programmable power supplies, and variable speed drives that convert, supply, control, clean, and distribute electrical power. Trade
Summary of the content on the page No. 3
Summary of the content on the page No. 4
About This Guide Conventions Used The following conventions are used in this guide. WARNING Warnings identify conditions that could result in personal injury or loss of life. CAUTION Cautions identify conditions or practices that could result in damage to the XPower Plus or other equipment. Important: These notes describe an important action item or an item that you must pay attention to. Note: Notes describe additional information which may add to your understanding of how to use the invert
Summary of the content on the page No. 5
iv
Summary of the content on the page No. 6
Important Safety Information Important: Before installing and using your XPower Plus, be sure to read these safety instructions and keep them handy. CAUTION Do not connect any AC load that has its neutral conductor connected to ground to the XPower Plus. CAUTION Do not connect the AC output of this inverter to any other source of power such as an electrical panel which itself may be AC powered from a utility generator or other source. Damage may occur. General Precautions 1. Before installi
Summary of the content on the page No. 7
Important Safety Information 6. To reduce the risk of overheating or fire, do not obstruct the ventilation openings, and do not install the inverter in a zero- clearance compartment. Explosive Gas Precautions WARNING: Explosion Hazard 1. Batteries generate explosive gases during normal operation. Be sure to read this guide and follow the instructions exactly before installing or using your inverter. 2. This equipment contains components which tend to produce arcs or sparks. To prevent fire o
Summary of the content on the page No. 8
Important Safety Information 5. Remove metal items like rings, bracelets, and watches when working with lead-acid batteries. Lead-acid batteries produce a short-circuit current high enough to weld a ring or the like to metal, and thus cause a severe burn. 6. If you need to remove a battery, always remove the ground terminal from the battery first. Make sure all accessories are off so you don’t cause a spark. Precautions For Using Rechargeable Appliances Most rechargeable battery-operated eq
Summary of the content on the page No. 9
Summary of the content on the page No. 10
Contents Important Safety Information General Precautions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - v Explosive Gas Precautions- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - vi Precautions When Working With Batteries - - - - - - - - - - - - - - - - - - - - - - - - - - vi Precautions For Using Rechargeable Appliances- - - - - - - - - - - - - - - - - - - - - - - vii 1Introduction Quality Power - - - - - - - - - - - - - -
Summary of the content on the page No. 11
Contents Installing the XPower Plus - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–14 Safety Instructions- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–14 Installation Tools and Materials - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–14 Overview of Installation Steps- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–16 Optional: Installing the Remote On/Off Switch - - - - - - - - - - - - - - - - - -
Summary of the content on the page No. 12
Contents Deep-Cycle Batteries - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–2 Battery Size - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–3 Estimating Battery Requirements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–4 Battery Sizing Example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–4 Battery Sizing Worksheet - - - - - - - - - - - - - - - - - - - - - - - - - - -
Summary of the content on the page No. 13
Summary of the content on the page No. 14
Introduction 1 Congratulations on your purchase of the XPower Plus! The XPower Plus inverter has been designed to give you quality power, ease of use, and reliability. Please take a few moments to read this chapter to familiarize yourself with the main performance features and protection features of the XPower Plus.
Summary of the content on the page No. 15
Introduction Quality Power The XPower Plus is a quality inverter designed for recreational vehicle (RV), marine, and truck applications. • The XPower 1200 Plus provides up to 1000 watts of continuous power. It is designed to handle loads such as 600 watt microwaves, TVs, VCRs, and midsized power tools. • The XPower 1750 Plus provides up to 1500 watts of continuous power. It is designed to handle loads such as 1000 watt microwaves, refrigerators, small freezers, circular saws, and small air
Summary of the content on the page No. 16
Comprehensive Protection Comprehensive Protection The XPower Plus is equipped with numerous protection features to guarantee safe and trouble-free operation: Low battery alarm Alerts you if the battery has become discharged to 10.7 V or lower. Low battery voltage shutdown Shuts the inverter down automatically if the battery voltage drops below 10.0 volts. This feature protects the battery from being completely discharged. High battery voltage shutdown Shuts the inverter down automatically i
Summary of the content on the page No. 17
1–4
Summary of the content on the page No. 18
XPower Plus Features 2 Chapter 2 describes the main features of the XPower Plus. Xantrex recommends that you familiarize yourself with them before installing and operating the inverter.
Summary of the content on the page No. 19
XPower Plus Features Materials List Your XPower Plus package includes: • One XPower Plus inverter • Two 5/16 inch lock washers (on the DC input cable terminals) • Two 5/16 inch nuts (on the DC input cable terminals) • Owner’s Guide If any of these materials are missing or are unsatisfactory in any way, please contact Customer Service. Phone: 1-800-670-0707 (toll free in North America) 1-604-420-1585 (outside North America) Fax: 1-800-994-7828 (toll free in North America) 1-604-420-1591 (outside
Summary of the content on the page No. 20
Optional Accessory: Remote On/Off Switch Instructions for installing and using the Remote On/Off Switch are included in the remote switch package. Note: If you are going to use the Remote On/Off switch, plug it into the remote switch jack on the bottom of the inverter before installing the inverter. The jack is not accessible once the inverter has been mounted. See “Choosing an Appropriate Location” on page 3–5. 2–3