InterAct Accessories 4040A user manual

User manual for the device InterAct Accessories 4040A

Device: InterAct Accessories 4040A
Category: Portable Generator
Manufacturer: InterAct Accessories
Size: 1.03 MB
Added : 4/4/2014
Number of pages: 49
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for InterAct Accessories 4040A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with InterAct Accessories 4040A.

For your convenience

If looking through the InterAct Accessories 4040A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual InterAct Accessories 4040A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual InterAct Accessories 4040A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
InterAct Accessories 4040A User manual - Online PDF
Advertisement
« Page 1 of 49 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual InterAct Accessories 4040A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to InterAct Accessories 4040A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


INSTRUCTION


MANUAL
Model 4040A
MANUAL DE INSTRUCCIÓN
MODELO 4040A


20 MHz SWEEP/FUNCTION
GENERATOR
with FREQUENCY COUNTER

20 MHz GENERADOR DE
BARRIDO/FUNCIONES CON
CONTADOR DE FRECUENCIA



Summary of the content on the page No. 2

TEST INSTRUMENT SAFETY WARNING Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must sometimes be performed where exposed voltage is present. An electrical shock causing 10 milliamps of current to pass through the heart will stop most human heartbeats. Voltage as low as 35 volts dc or ac rms should be considered dangerous and hazardous since it can produce a lethal current under certain conditions. Higher voltages pose

Summary of the content on the page No. 3

Instruction Manual for Model 4040A 20 MHz SWEEP/FUNCTION GENERATOR with FREQUENCY COUNTER 22820 Savi Ranch Parkway • Yorba Linda, CA 92887 3

Summary of the content on the page No. 4

TABLE OF CONTENTS TEST INSTRUMENT SAFETY ...........inside front cover Voltage Controlled Frequency Operation ........................17 INTRODUCTION ........................................................ 5 Sweep Operation............................................................ 18 SPECIFICATIONS ...................................................... 6 Use of Frequency Counter with External Signals ............ 18 CONTROLS AND INDICATORS ................................ 8 Ou

Summary of the content on the page No. 5

Summary of the content on the page No. 6

SPECIFICATIONS FREQUENCY CHARACTERISTICS Waveforms: Sine, Square, Triangle, ± Pulse, ± Ramp Square Wave Range: 0.2Hz to 20MHZ in 8 ranges Symmetry: ≤2% 0.2Hz to 100kHz Resolution: Rise Time: ≤30ns (Typical) Tuning Range: Coarse: 10:1, Fine: ± 5% of Coarse Overshoot & Setting Undershoot ≤5% Variable Duty Cycle 15:85:15 Continuously Variable Operating Modes Normal, Sweep, VCG, AM, FM, Burst TRIANGLE WAVE Frequency Stability: The output will change less tha

Summary of the content on the page No. 7

SPECIFICATIONS Repetition Rate: 0.5Hz to 50Hz, internal or DC to SWEEP OPERATION 500kHz, external Mode: LIN / LOG Burst Frequency: Determined by the main generator Width: 100:1, Continuously variable frequency setting. Tone burst is in Rate: 20mS to 2 sec, continuously integral cycles of frequency being variable gated. Sweep Output: 0 to 2V FREQUENCY COUNTER Start/Stop Accuracy: Time Base Accuracy ±1 Frequencies: Adjustable count AM MODULATION CHARACTERISTICS T

Summary of the content on the page No. 8

Summary of the content on the page No. 9

Figure 1. Model 4040A Front Panel. 19 BURST OFF/ON Switch. Selects external or 17. BURST WIDTH Control. Adjusts the duty internal burst gate. Continuous output is obtained cycle of the internal burst gate. with switch in the OFF position and no external 18. % MODULATION Control. Adjusts the burst gate is applied. percentage of AM or FM modulation. 9

Summary of the content on the page No. 10

CONTROLS AND INDICATORS 27. SWEEP STOP Control. Adjusts the ending sweep 20. .START/STOP Switch. Enables adjustment of the starting frequency. and stopping sweep frequencies. The actual adjustment is 28. COARSE FREQUENCY Control. Coarse adjustment performed by the SWEEP START and SWEEP STOP of the output frequency from 0.1 to 1 times the selected controls (29 and 27). START/STOP selection is enabled range. only when the SET/RUN switch (21) is set to SET. 29. SWEEP START

Summary of the content on the page No. 11

OPERATING INSTRUCTIONS The B&K Precision Model 4040A Sweep/Function Generator is a 5. Rotate the COARSE (28) frequency control to quickly set the versatile instrument, capable of producing a variety of output output frequency to the approximate desired value. The FINE waveforms over a broad range of frequencies. To gain a working (26) frequency control can then be used to easily set the output familiarity with the unit, it is recommended that it be connected to the specific desired

Summary of the content on the page No. 12

OPERATING INSTRUCTIONS 6. Adjust the amplitude of the output as desired using the OUTPUT LEVEL control (10). Rotation of this control varies the amplitude from maximum to 20dB below maximum. An additional attenuation of -20dB is available by pushing in the -20dB switch (5). The attenuation factors can be combined for a total of -40dB. The maximum signal level is 10V p-p (into 50 Ω). 7. A DC component can be added to the output signal by pushing in the DC OFFSET switch (4) to enabl

Summary of the content on the page No. 13

OPERATING INSTRUCTIONS 4. When the 2 Hz range is selected, the gate time is 10 seconds and the display is updated once every 10 seconds. The result of a frequency change will not be displayed until 10 seconds later. Adjust the frequency in progressively smaller steps, waiting for the display to update until the desired frequency is obtained. 5. When outputting square waves or when using the TTL output, terminate the cable into 50 Ω to minimize ringing. Also, keep cables as short

Summary of the content on the page No. 14

OPERATING INSTRUCTIONS 3. Varying the duty cycle setting results in a slight change in frequency. Adjust the COARSE and FINE frequency controls as required. BURST OPERATION In gated burst mode of operation, the generator output is switched on and off (gated), either by an internally generated signal or by an externally applied signal. Both the repetition rate and the duty cycle are variable. Fig. 5 illu

Summary of the content on the page No. 15

OPERATING INSTRUCTIONS 3. With BURST ON/OFF switch in OFF position, apply a AM OPERATION TTL gating signal of the proper width to the front panel The output of Model 4040A can be amplitude-modulated, BURST INPUT jack. either by the internal 1 kHz signal, or by an external signal applied to the VCG/MOD INPUT jack. Considerations Internal l. Make sure the tone burst and entire off period is viewed when setting the repetition rate. The visible portion of the 1. Set the

Summary of the content on the page No. 16

OPERATING INSTRUCTIONS 3. Place the EXT MODULATION switch in the released position. 4. Connect a suitable modulating signal to the VCG/MOD INPUT jack on the front panel. 5. Adjust the modulation level as described previously. FM OPERATION The output of the Model 4040 can be frequency-modulated, either by the internal 1 kHz internal signal or by an external signal applied to the front panel VCG/MOD INPUT jack. Internal 1. Set the carrier frequency using the main FREQUENCY cont

Summary of the content on the page No. 17

OPERATING INSTRUCTIONS 4. Connect a suitable modulation signal to the VCG/MOD will vary the frequency which is pre-selected by the range INPUT jack on the front panel. switches and the frequency controls. Applying 5. Adjust the amplitude and frequency of the external approximately +l0 V with the COARSE control at full signal as required. Typically, a signal less than 10V p- clockwise decreases the output frequency by about 100 p will provide 10% modulation of the carrier.

Summary of the content on the page No. 18

OPERATING INSTRUCTIONS SWEEP OPERATION USE OF FREQUENCY COUNTER WITH EXTERNAL SIGNALS 1. Select LINEAR sweep by leaving the SWEEP LIN/LOG switch (23) in the released position or select LOG sweep by engaging the The frequency counter display in the Model 4040 is SWEEP LIN/LOG switch. normally used to monitor the internally generated output. 2. Rotate COARSE FREQUENCY Control to minimum (CCW). However, it can also be used as a stand-alone frequency 3. Engage t

Summary of the content on the page No. 19

OPERATING INSTRUCTIONS OUTPUT PROTECTION CONSIDERATIONS Use care when connecting the function generator output to a signal injection point. Excessive voltage at the point of signal injection of the function generator can cause internal damage. Under normal operation, the generator output should never be connected to an external voltage other than low dc values that can be matched with the DC OFFSET control. The Model 4040 is overload protect

Summary of the content on the page No. 20

MAINTENANCE INSTRUMENT REPAIR SERVICE WARNING The following instructions are for use by qualified service personnel Because of the specialized skills and test equipment required for only. To avoid electrical shock, do not perform servicing other than instrument repair and calibration, many customers prefer to rely contain ed in the operating instructions unless you are qualified to upon B+K PRECISION for this service. We maintain a network do so. of B+K PRECISION au


Alternative user manuals
# User manual Category Download
1 ACDelco AC-G0005 User manual Portable Generator 1
2 ACDelco AC-G0002 User manual Portable Generator 0
3 ACDelco AC-G0004 User manual Portable Generator 3
4 AEG 2.33 2 User manual Portable Generator 3
5 ACDelco AC-G0003 User manual Portable Generator 0
6 Agilent Technologies 669xA User manual Portable Generator 1
7 Agilent Technologies 66309B User manual Portable Generator 5
8 Agilent Technologies 665xA User manual Portable Generator 1
9 Agilent Technologies 83622B User manual Portable Generator 2
10 Agilent Technologies 8360 User manual Portable Generator 1
11 Agilent Technologies 664xA User manual Portable Generator 1
12 Agilent Technologies 66111A User manual Portable Generator 1
13 Agilent Technologies 668xA User manual Portable Generator 1
14 Agilent Technologies 83623L User manual Portable Generator 2
15 Agilent Technologies 83640B User manual Portable Generator 8