Generac Power Systems 04758-2, 04759-2, 04760-2 user manual

User manual for the device Generac Power Systems 04758-2, 04759-2, 04760-2

Device: Generac Power Systems 04758-2, 04759-2, 04760-2
Category: Portable Generator
Manufacturer: Generac Power Systems
Size: 5.24 MB
Added : 7/17/2014
Number of pages: 56
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Generac Power Systems 04758-2, 04759-2, 04760-2. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Generac Power Systems 04758-2, 04759-2, 04760-2.

For your convenience

If looking through the Generac Power Systems 04758-2, 04759-2, 04760-2 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Generac Power Systems 04758-2, 04759-2, 04760-2 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Generac Power Systems 04758-2, 04759-2, 04760-2 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Generac Power Systems 04758-2, 04759-2, 04760-2 User manual - Online PDF
Advertisement
« Page 1 of 56 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Generac Power Systems 04758-2, 04759-2, 04760-2 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Generac Power Systems 04758-2, 04759-2, 04760-2. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation and
Owner’s Manual
Air-cooled Automatic
Standby Generators
Models:
04758-2 (6 kW NG, 7 kW LP)
04759-2 (12 kW NG, 12 kW LP)
04760-2 (13 kW NG, 15 kW LP)
R
GENERAC
POWER SYSTEMS, INC.
R
*This manual should remain with the unit.*
Not intended for use as Primary Power in place of utility
!
!
or in life-support applications.
DANGER
DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY!!

Summary of the content on the page No. 2

This symbol points out important safety informa- INTRODUCTION ! tion that, if not followed, could endanger personal Thank you for purchasing this Guardian model by Generac safety and/or property of others. Power Systems Inc.. This model is a compact, high per- formance, air-cooled, engine-driven generator designed to This symbol points out potential explosion hazard. automatically supply electrical power to operate critical loads during a utility power failure. This symbol points out potential f

Summary of the content on the page No. 3

Table of Contents Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators 3.2.2 “Off” Position....................................14 Introduction ........................Inside Front Cover Read This Manual Thoroughly ........................IFC 3.2.3 “Manual” Position ............................14 Contents ..........................................................IFC 3.3 Automatic Transfer Operation ....................15 Operation and Maintenance ............................IFC 3.4 Sequence of Au

Summary of the content on the page No. 4

IMPORTANT SAFETY INSTRUCTIONS Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted near the unit’s installation site. Safety should be stressed to ! ! all operators and potential operators of this equipment. ! ! ! ! WARNING: GENERAL HAZARDS The engine exhaust from this product  For safety reasons, Generac recommends that the contains chemicals known to the state of California to cause c

Summary of the content on the page No. 5

IMPORTANT SAFETY INSTRUCTIONS Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators  Keep a fire extinguisher near the generator at all times. Extinguishers rated “ABC” by the National ELECTRICAL HAZARDS Fire Protection Association are appropriate for use on the standby electric system. Keep the extin-  All generators covered by this manual produce dangerous electrical voltages and can cause fatal guisher properly charged and be familiar with its use. If there are any questions pertaining to fi

Summary of the content on the page No. 6

Section 1 — General Information Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators 1.2 PROTECTION SYSTEMS DANGER Unlike an automobile engine, the generator may have Only qualified electricians or contractors should to run for long periods of time with no operator pres- ! attempt such installations, which must comply ent to monitor engine conditions. For that reason, the strictly with applicable codes, standards and engine is equipped with the following systems that regulations. protect it agai

Summary of the content on the page No. 7

Section 1 — General Information Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators 1.4 THE GENERATOR Figure 1.1 – 7 kW, Single Cylinder GH-410 Engine Control Panel Oil Data Dipstick Decal GFCI Outlet Exhaust Enclosure Fuel Regulator Fuel Inlet Battery Oil Filter Compartment Figure 1.2 – 12 kW/15 kW, V-twin GT-990/760 Engine Control Panel Oil Data Dipstick Decal GFCI Outlet Exhaust Enclosure Fuel Regulator Fuel Inlet Composite Base Battery Oil Filter Compartment Generac® Power Systems, Inc. 5

Summary of the content on the page No. 8

Section 1 — General Information Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators 1.5 SPECIFICATIONS 1.5.1 GENERATOR Model 04758 Model 04759 Model 04760 Rated Max. Continuous Power Capacity (Watts*) 6,000 NG/7,000 LP 12,000 NG/12,000 LP 13,000 NG/15,000 LP† Rated Voltage 120/240 120/240 120/240 Rated Max. Continuous Load Current (Amps) 120 Volts + 50.0 NG/58.3 LP 100.0 NG/100.0 LP 108.3 NG/125.0 LP 240 Volts 25.0 NG/29.2 LP 50.0 NG/50.0 LP 54.2 NG/62.5 LP Main Line Circuit Breaker 30 Amp 50

Summary of the content on the page No. 9

Section 1 — General Information Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators 1.6 FUEL REQUIREMENTS 1.8 RECONFIGURING THE AND RECOMMENDATIONS FUEL SYSTEM With LP gas, use only the vapor withdrawal system. This type of system uses the vapors formed 1.8.1 7 KW, 410CC ◆ above the liquid fuel in the storage tank. To reconfigure the fuel system from NG to LP, The engine has been fitted with a fuel carburetion follow these steps (Figure 1.3): system that meets the specifications of the 1997 N

Summary of the content on the page No. 10

Section 1 — General Information Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators Figure 1.4 - Demand Regulator 1.8.2 12KW AND 15KW, 990CC ENGINES ◆ To reconfigure the fuel system from NG to LP, OUTLET PORTS follow these steps: FUEL HOSE NOTE: BRASS HOSE FITTING The primary regulator for the propane supply is IDLE CIRCUIT BRASS HOSE U SMALL PORT T FITTING 1 TAP FUEL JET NOT INCLUDED with the generator. A fuel pres- 1/8 NPT REGULATOR sure of 11 to 14 inches of water column (0.4 to 0.5 HOUSING

Summary of the content on the page No. 11

Section 1 — General Information Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators Figure 1.5 – Battery Cable Connections 1.9.2 TRANSFER SWITCH ◆ 1.9.2.1 7 kW, 12 kW and 15 kW Units Transfer switches for use with these generators are sold separately and can be purchased from Generac Authorized Dealers.  Install the transfer switch on a firm, sturdy sup- porting structure.  To prevent switch distortion, level the switch if nec- essary. This can be done by placing washers between the switch

Summary of the content on the page No. 12

Section 2 — Post Installation Start-up and Adjustments Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators • Remove watches, rings or other metal objects; 2.1 BEFORE INITIAL START-UP  Use tools with insulated handles; Before starting, complete the following:  Wear rubber gloves and boots; 1. Set the generator’s main circuit breaker to its  Do not lay tools or metal parts on top of the OFF (or open) position. battery; and  Disconnect charging source prior to connecting or dis- 2. Set the ge

Summary of the content on the page No. 13

Section 2 — Post Installation Start-up and Adjustments Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators 3. Check utility power source voltage across termi- 3. Turn OFF the utility power supply to the transfer nals N1 and the transfer switch neutral lug; then switch, using the means provided (such as a util- across terminal N2 and neutral. Nominal line-to- ity main line circuit breaker). neutral voltage should be 120 volts AC. 4. When certain that utility supply voltage is com- patible with t

Summary of the content on the page No. 14

Section 2 — Post Installation Start-up and Adjustments Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators 4. Manually set the transfer switch to the UTILITY 4. When full load has been achieved. Connect a fre- position, i.e., load terminals connected to the util- quency meter to the output lugs of the generator’s ity power source side. main line circuit breaker. 5. Turn ON the utility power supply to the transfer 5. The fuel regulator is fitted with one (7 kW), or two switch, using the means pr

Summary of the content on the page No. 15

Section 2 — Post Installation Start-up and Adjustments Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators If this procedure or equipment are not available, 2.7.2 12 KW AND 15 KW UNITS ◆ locate the nearest Generac Guardian Dealer and they 1. Loosen governor clamp bolt (See Figure 2.4). can perform the adjustments. NOTE: Figure 2.4 — V-twin Engine Governor Adjustment A service fee may be charged for this adjustment. 2.7 ENGINE GOVERNOR ADJUSTMENT If both AC frequency and voltage are correspondin

Summary of the content on the page No. 16

Section 3 — Operation Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators 7. Run the unit for one hour at 100 percent load. 2.7.3 ADDITIONAL CORROSION ◆ 8. Turn ON the utility power supply to the transfer PROTECTION switch, which will allow the transfer switch to Periodically spray all engine linkage parts and brack- transfer back to utility power. The unit will con- ets with corrosion inhibiting spray such as WD-40 or tinue to run for one minute and then shut down. a comparable product. 9. Al

Summary of the content on the page No. 17

Section 3 — Operation Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators D.Utility Voltage Pickup Sensor 3.3 AUTOMATIC TRANSFER  This sensor monitors utility power supply volt- OPERATION age. When that voltage is restored to above 70 To select automatic operation, do the following: percent of the nominal source voltage, a retrans- fer time delay starts timing. 1. Make sure the transfer switch main contacts are set to their “Utility” position, i.e., loads connected E.Retransfer Time Delay t

Summary of the content on the page No. 18

Section 3 — Operation Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators Figure 3.2 – Manual Transfer Switch Operation 3.6 SETTING THE EXERCISE TIMER The generator is equipped with an exercise timer. Once it is set, the generator will start and exercise once every seven days, on the day of the week and at the time of day the following sequence is completed. During this exercise period, the unit runs for approx- imately 12 minutes and then shuts down. Transfer of loads to the generator output d

Summary of the content on the page No. 19

n e s o o L Section 4 — Maintenance Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators The generator panel’s 5 amp fuse protects the battery Figure 3.3 – Low Oil Pressure and charge circuit against overload. If the fuse element has High Temperature Switches melted open, battery charging capability will not be pos- Low Oil Switch High Temp Switch sible. Replace the fuse using only an identical 5 amp replacement. To remove fuse, push cap down and rotate counterclockwise. Figure 4.1 – Generator

Summary of the content on the page No. 20

n e s o o L Section 4 — Maintenance Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators 4. Install the dipstick. Figure 4.4 – Oil Drain Hose and Filter 5. Reset the AUTO/OFF/MANUAL switch to its origi- nal position. Figure 4.3 — Oil Dipstick and Fill, 12 kW and 15 kW Oil Dipstick Oil Drain Oil Fill Hose Oil Filter 4.4 CHANGING THE OIL FILTER Change the engine oil filter as follows: 1. With the oil drained, remove the old oil filter by turning it counterclockwise. 2. Apply a light coating of cl


Alternative user manuals
# User manual Category Download
1 Generac Power Systems 004373-6 User manual Portable Generator 6
2 Generac Power Systems 0043734 User manual Portable Generator 3
3 Generac Power Systems 0043735 User manual Portable Generator 3
4 Generac Power Systems 0043733 User manual Portable Generator 2
5 Generac Power Systems 004371-2 User manual Portable Generator 0
6 Generac Power Systems 004626-5 User manual Portable Generator 0
7 Generac Power Systems 0046263 User manual Portable Generator 0
8 Generac Power Systems 004270-1 User manual Portable Generator 0
9 Generac Power Systems 004474-1 User manual Portable Generator 0
10 Generac Power Systems 004701-0 User manual Portable Generator 0
11 Generac Power Systems 004709-0 User manual Portable Generator 1
12 Generac Power Systems 004988-2 User manual Portable Generator 1
13 Generac Power Systems 004917-4 User manual Portable Generator 1
14 Generac Power Systems 004987-2, 005396-0 User manual Portable Generator 2
15 Generac Power Systems 004917-3 User manual Portable Generator 0
16 ACDelco AC-G0005 User manual Portable Generator 1
17 ACDelco AC-G0002 User manual Portable Generator 0
18 ACDelco AC-G0004 User manual Portable Generator 3
19 AEG 2.33 2 User manual Portable Generator 3
20 ACDelco AC-G0003 User manual Portable Generator 0