Electrolux QB1300 user manual

User manual for the device Electrolux QB1300

Device: Electrolux QB1300
Category: Portable Generator
Manufacturer: Electrolux
Size: 1.49 MB
Added : 12/29/2013
Number of pages: 25
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Electrolux QB1300. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Electrolux QB1300.

For your convenience

If looking through the Electrolux QB1300 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Electrolux QB1300 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Electrolux QB1300 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Electrolux QB1300 User manual - Online PDF
Advertisement
« Page 1 of 25 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Electrolux QB1300 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Electrolux QB1300. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



Gasoline Generators
Operator Manual




















Summary of the content on the page No. 2

Thank you for purchasing our generator. We want to help you get the best results from your new generator and to operate it safely. This manual contains the information on how to do that; please read it carefully. This owner’s manual describes the operation and maintenance of the Generator. All information in this publication is based on the latest product information available at the time of printing. We reserve the right to make changes at any time without notice and without incurring any o

Summary of the content on the page No. 3

Table Of Contents SAFETY 2 SAFETY LABEL LOCATION 4 SAFETY INFORMATION 5 Component Identification 6 CONTROLS 7 7 Engine Switch 7 Recoil Starter Fuel Valve 7 Choke Rod 8 Circuit Breaker 8 Ground Terminal 8 Oil Alert System 8 Pilot Lamp 8 DC Terminals 8 DC Circuit Protector 9 9 GENERATOR USE 9 Connections to a Building’s Electrical System Generator Ground Circuit 9 AC Applications 9 AC Operation 10 DC Operation 10 Disconnecting the battery cables 11 PREOPERATION CHECK 11 Engine Oil 11 Fuel

Summary of the content on the page No. 4

SAFETY LABEL LOCATION These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your generator dealer for a replacement. 4

Summary of the content on the page No. 5

WARNING! Do not connect to a building’s electrical system unless a transfer switch has been installed by a qualified electrician. Using a generator or an electrical appliance in wet conditions such as rain or snow or near a pool or sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator dry. SAFETY INFORMATION Generators are designed to give safe and dependable service if operated according to instructions. Read and understand this owner’s manual

Summary of the content on the page No. 6

• Do not smoke or allow flames or sparks where the generator is refueled or where gasoline is stored. • Refuel in a well-ventilated area with the engine stopped. Fuel vapors are extremely flammable and may ignite after the engine has started. Make sure that any spilled fuel has been wiped up before starting the generator. Record the engine serial number for your future reference. (See Page 6) Refer to this serial number when ordering parts, and when making technical requests. Engine

Summary of the content on the page No. 7

CONTROLS Engine Switch To start and stop the engine. Switch position: OFF: To Stop the engine. Key can be removed/inserted. ON: To run the engine after starting. START: To start the engine by turning the starter motor. Return the key to the ON position once the engine has started. Do not use the starter for more than 5 seconds at a time. If the engine fails to start, release the switch and wait 10 seconds before o

Summary of the content on the page No. 8

Choke Rod The choke is used to provide an enriched fuel mixture when cold starting. The choke can be opened by moving the choke rod to the right and closed by moving the choke rod to the left. Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the generator at the receptacle. lf the circuit breaker is switched OFF automatically, check that the appliance is working properly and does not exceed the rated load ca

Summary of the content on the page No. 9

battery must be connected to the generator DC terminals with the proper polarity (battery positive to generator red terminal and battery negative to the generator black terminal.) DC Circuit Protector The DC circuit protector automatically shuts off the DC battery charging circuit when the generator is overloaded, when there is a problem with the battery or the connections between the battery and the generator are improper. GENERATOR USE Connections to a Building’s Electrical System

Summary of the content on the page No. 10

exceed that of the generator, Never exceed the maximum power rating of the generator. Power levels between rated and maximum may be used for no more than 5 minutes. NOTICE Substantial overloading will open the circuit breaker. Exceeding the time limit for maximum power operation or slightly overloading the generator may not switch the circuit breaker OFF, but will shorten the service life of the generator. Limit operation requiring maximum power to 5 minutes. Maximum power is: See spe

Summary of the content on the page No. 11

Disconnecting the battery cables: 1. Stop the engine. 2. Disconnect the negative (-) battery cable from the generator negative (-) terminal. 3. Disconnect the other end of the negative (-) battery cable from the battery negative (-) terminal. 4. Disconnect the positive (+) battery cable from the generator positive (+) terminal. 5. Disconnect the other end of the positive (+) battery cable to the battery positive (+) terminal. 6. Connect the vehicle ground cable to the battery negative (-)

Summary of the content on the page No. 12

Fuel Recommendation 1. Check the fuel level gauge. 2. Refill the tank if the fuel level is low. Do not fill above the shoulder of the fuel strainer. WARNING Gasoline is extremely flammable and is explosive under certain conditions. Refuel in a well-ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored. Do not overfill the fuel tank (there should be no fuel in the filler neck). After refu

Summary of the content on the page No. 13

Gasoline containing more than 10% ethanol by volume may cause starting and/or performance problems. Gasoline containing ethanol may be marketed under the name Gasohol. Methanol (methyl or wood alcohol) Gasoline containing methanol must contain co solvents and corrosion inhibitors to protect the fuel system. Gasoline containing more than 5% methanol by volume may cause starting and/or performance problems and may damage metal, rubber and plastic parts of your fuel system. MTBE (methyl terti

Summary of the content on the page No. 14

STOPPING In an emergency: 1. To stop the engine in an emergency, turn the engine switch to the OFF position. In normal use: 1. Turn the AC circuit breaker to the OFF position. 2. Disconnect all electrical loads from panel receptacles. Disconnect DC battery charging cables. 3. Turn the engine switch to the OFF position. 4. Turn the fuel valve to the OFF position. MAINTENENCE Periodic maintenance and adjustment is necessary to keep the generator in good operating condition.

Summary of the content on the page No. 15

Maintenance Schedule Notes 1) Service more frequently when used in dusty areas. 2) These items should be serviced by an authorized generator dealer, unless owner has proper tools and is mechanically proficient. 3) For professional commercial use, log hours of operation to determine proper maintenance intervals. Engine oil change Drain the oil while the engine is warm to assure rapid and complete draining. 1. Remove the drain plug and sealing washer, oil filler cap, and drain the oil

Summary of the content on the page No. 16

Please dispose of used motor oil in a manner that is compatible with the environment. We suggest you take it in a sealed container to your local service station or recycling center for disposal. Do not throw it in the trash or pour it on the ground. Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. Using gas

Summary of the content on the page No. 17

Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water, which may be in the fuel tank, from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1. Turn the fuel valve to the OFF position. Remove the sediment cup, O-ring, and filter. 2. Clean the sediment cup, O-ring, and filter in nonflammable or high flash point solvent. 3. Reinstall the filter, O-ring, and sediment cup. 4. Turn the fuel valve ON and check for leaks.

Summary of the content on the page No. 18

NOTICE The spark plug must be securely tightened. An improperly tightened spark plug can become very hot and could damage the engine. Never use spark plugs which have an improper heat range. Use only the recommended spark plugs or equivalent. TRANSPORTATION/STORAGE When transporting the generator, turn the engine switch and the fuel valve OFF. Keep the generator level to prevent fuel spillage. Fuel vapor or spilled fuel may ignite. Contact with a hot engine or exhaust system can cause s

Summary of the content on the page No. 19

Gasoline is extremely flammable and is explosive under certain conditions Perform this task in a well ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area during this procedure. 1. Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container. 2. Change the engine oil. 3. Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil

Summary of the content on the page No. 20

TROUBLE SHOOTING TYPICAL WIRING DIAGRAM 20


Alternative user manuals
# User manual Category Download
1 Electrolux QB2800 User manual Portable Generator 1
2 Electrolux QB3300 User manual Portable Generator 1
3 Electrolux QB7700 User manual Portable Generator 0
4 Electrolux QB5500 User manual Portable Generator 1
5 ACDelco AC-G0005 User manual Portable Generator 1
6 ACDelco AC-G0002 User manual Portable Generator 0
7 ACDelco AC-G0004 User manual Portable Generator 3
8 AEG 2.33 2 User manual Portable Generator 3
9 ACDelco AC-G0003 User manual Portable Generator 0
10 Agilent Technologies 669xA User manual Portable Generator 1
11 Agilent Technologies 66309B User manual Portable Generator 5
12 Agilent Technologies 665xA User manual Portable Generator 1
13 Agilent Technologies 83622B User manual Portable Generator 2
14 Agilent Technologies 8360 User manual Portable Generator 1
15 Agilent Technologies 664xA User manual Portable Generator 1