Bryant ASPAS1BBA012 user manual

User manual for the device Bryant ASPAS1BBA012

Device: Bryant ASPAS1BBA012
Category: Portable Generator
Manufacturer: Bryant
Size: 0.86 MB
Added : 9/3/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant ASPAS1BBA012. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant ASPAS1BBA012.

For your convenience

If looking through the Bryant ASPAS1BBA012 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant ASPAS1BBA012 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant ASPAS1BBA012 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant ASPAS1BBA012 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant ASPAS1BBA012 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant ASPAS1BBA012. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Owner’s Manual
Air-cooled, Prepackaged
Automatic Standby Generators
Models:
C US
ASPAS1BBA007 (6 kW NG, 7 kW LP)
ASPAS1BBA012 (12 kW NG, 12 kW LP)
LISTED
ASPAS1BBA015 (13 kW NG, 15 kW LP)
R
GENERAC
POWER SYSTEMS, INC.
R
Not intended for use as Primary Power in place of utility or in
!
!
life-support applications.
DANGER
DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY!!

Summary of the content on the page No. 2

The operator is responsible for proper and safe use INTRODUCTION of the equipment. Bryant strongly recommends that the Thank you for purchasing this model of the Bryant operator read this Owner's Manual and thoroughly product line. This model is a compact, high performance, understand all instructions before using this equipment. air-cooled, engine-driven generator designed to Bryant also strongly recommends instructing other users automatically supply electrical power to operate critical to pr

Summary of the content on the page No. 3

Table of Contents Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators Introduction ........................Inside Front Cover Section 3 – Maintenance ..............................12 Read This Manual Thoroughly ..............................IFC 3.1 Fuses ................................................................12 Contents ................................................................IFC 3.2 Checking the Engine Oil Level ..........................13 Operation and Maintenance .............

Summary of the content on the page No. 4

IMPORTANT SAFETY INSTRUCTIONS Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted near the unit’s installation site. Safety should be stressed to all ! ! operators and potential operators of this equipment. ! ! ! ! WARNING: GENERAL HAZARDS The engine exhaust from this product • For safety reasons, Bryant recommends that the contains chemicals known to the state of California to cause canc

Summary of the content on the page No. 5

IMPORTANT SAFETY INSTRUCTIONS Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators Extinguishers rated “ABC” by the National Fire Protection Association are appropriate for use on the ELECTRICAL HAZARDS standby electric system. Keep the extinguisher properly charged and be familiar with its use. Consult • All generators covered by this manual produce dangerous electrical voltages and can cause fatal the local fire department with any questions pertaining to fire extinguishers. electrical shock. Ut

Summary of the content on the page No. 6

Section 1 — General Information Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators There are LED readouts on the control panel to notify DANGER personnel that one of these faults has occurred. There is also a “System Set” LED that is lit when all of the Only qualified electricians or contractors should conditions describe in Section 1.3 are true. ! attempt such installations, which must comply strictly with applicable codes, standards and regulations. 1.3 NEC REQUIREMENT FOR ARC FAULT CIRCUIT IN

Summary of the content on the page No. 7

Section 1 — General Information Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators 1.4 THE GENERATOR Figure 1.1 – 7 kW, Single Cylinder GH-410 Engine Control Panel Oil Data Dipstick Decal GFCI Outlet Exhaust Enclosure Fuel Regulator Fuel Inlet Lifting holes (4 places) Battery Oil Filter Compartment Figure 1.2 – 12 kW and 15 kW, V-twin GT-990 Engine Control Panel Oil Data Dipstick Decal GFCI Outlet Exhaust Enclosure Fuel Regulator Fuel Inlet Lifting holes (4 places) Composite Base Battery Oil Fil

Summary of the content on the page No. 8

Section 1 — General Information Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators 1.5 SPECIFICATIONS 1.5.1 GENERATOR Model ASPAS1BBA007 ASPAS1BBA012 ASPAS1BBA015 Rated Max. Continuous Power Capacity (Watts*) 6,000 NG/7,000 LP 12,000 NG/12,000 LP 13,000 NG/15,000 LP Rated Voltage 120/240 120/240 120/240 Rated Max. Continuous Load Current (Amps) 120 Volts** 50.0 NG/58.3 LP 100.0 NG/100.0 LP 108.3 NG/125.0 LP 240 Volts 25.0 NG/29.2 LP 50.0 NG/50.0 LP 54.2 NG/62.5 LP Main Line Circuit Breaker 30 A

Summary of the content on the page No. 9

Section 1 — General Information Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators Should the primary fuel need to be changed to LP gas, Excercise caution when lifting the unit manually as it ! the fuel system needs to be reconfigured. See Section may shift on lifting pipes during transportation, which 1.9 for instructions on reconfiguration of the fuel system. may result in injury. Recommended fuels should have a Btu content of at 1.9.2 PLACEMENT ◆ least 1,000 Btus per cubic foot for natural ga

Summary of the content on the page No. 10

Section 1 — General Information Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators A battery presents a risk of electrical shock 1.10 BATTERY INSTALLATION and high short circuit current. The following Fill the battery with the proper electrolyte fluid if precautions are to be observed when working necessary and have the battery fully charged before on batteries: installing it. • Remove the 7.5A and 15A fuses from the Before installing and connecting the battery, complete generator control panel

Summary of the content on the page No. 11

Section 2 — Operation Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators Servicing of the battery is to be performed or supervised 12. Drain the oil and remove the oil filter. Replace the oil by personnel knowledgeable of batteries and the filter according to Section 3.4, “Changing the Oil required precautions. Keep unauthorized personnel Filter”. Replace the oil with synthetic oil as away from batteries. recommended in Section 3.3, “Changing the Engine Oil”. When replacing the battery, use the

Summary of the content on the page No. 12

Section 2 — Operation Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators 2.3 AUTOMATIC TRANSFER 2.4 SEQUENCE OF AUTOMATIC OPERATION OPERATION To select automatic operation, do the following: The generator’s control panel houses a control logic circuit board. This board constantly monitors utility power 1. Make sure the transfer switch main contacts are set source voltage. Should that voltage drop below a preset to their UTILITY position, i.e., loads connected to the level, circuit board action

Summary of the content on the page No. 13

Section 2 — Operation Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators 2.5.2 TRANSFER BACK TO UTILITY POWER 2.5 MANUAL TRANSFER OPERATION SOURCE 2.5.1 TRANSFER TO GENERATOR When utility power has been restored, transfer back to POWER SOURCE that source and shut down the generator. This can be accomplished as follows: To start the generator and activate the transfer switch manually, proceed as follows: 1. Set the generator’s main circuit breaker to its OFF (or open) position. 1. Set the gene

Summary of the content on the page No. 14

n e s o o L Section 2 — Operation Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators NOTE: 2.7.3 OVER CRANK The exerciser will only work in the AUTO mode and This feature prevents the generator from damaging itself will not work unless this procedure is performed. The when it continually attempts to start and another problem, exerciser will need to be reset every time the 12-volt such as no fuel supply, prevents it from starting. The unit battery is disconnected and then reconnected. will crank

Summary of the content on the page No. 15

Section 3 — Maintenance MAINTENENANCE Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators Figure 3.1 – Generator Control Panel Figure 3.3 — Oil Dipstick and Fill, 12 kW and 15 kW EXTERNAL OUTLET FUSE Oil Dipstick GFCI CIRCUIT 7.5A BREAKER AUTO OFF MAN. SYSTEM SET LOW OIL 12 VDC HIGH TEMP. SYST OVER SPEED OVER CRANK Oil Fill F L A S H I N L E D = SET N O S E N S E EXERCISE ACCESSORY 4 F L S H R E L E D S = E X E R R N O T S E T TIME OUTLET 7.5A MAX 3.2 CHECKING THE ENGINE OIL LEVEL For oil capaci

Summary of the content on the page No. 16

n e s o o L Section 3 — Maintenance MAINTENENANCE Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators Figure 3.4 – Oil Drain Hose and Filter Figure 3.5 — 7 kW, Engine Air Cleaner Location Fuel Low Oil Switch High Temp Switch Air Cleaner Regulator Screw Oil Drain 3/4” Hole Hose Oil Filter Figure 3.6 — 12 kW and 15 kW Engine Air Cleaner 3.4 CHANGING THE OIL FILTER Screw Change the engine oil filter as follows: 1. With the oil drained, remove the old oil filter by turning it counterclockwise. 2. App

Summary of the content on the page No. 17

Section 3 — Maintenance MAINTENENANCE Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators  Wear full eye protection and protective clothing; Figure 3.7 – Setting the Spark Plug Gap  Where electrolyte contacts the skin, wash it off SET PLUG GAP AT 0.76 mm (.030 inch) - 7 kW immediately with water; 0.508 mm (.020 inch) - 12 kW & 15 kW  Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention; and  Spilled electrolyte is to be washed down with

Summary of the content on the page No. 18

Section 3 — Maintenance MAINTENENANCE Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators 5. Set the AUTO/OFF/MANUAL switch to OFF and turn Figure 3.8 – Cooling Vent Locations off the utility power to the transfer switch. Remove the 7.5A and 15A fuses from the generator control panel. Disconnect the battery cables as outlined in “General Hazards” (page 2). Turn on the utility power supply to the transfer switch in order to power the emergency load centers circuits while utility power is available

Summary of the content on the page No. 19

Section 4 — Service SERVICE Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators 4.1 SERVICE SCHEDULE ATTENTION: It is recommended that all service work be performed by the nearest Bryant Dealer. SYSTEM/COMPONENT PROCEDURE FREQUENCY X = Action Inspect Change Clean W = Weekly R = Replace as Necessary M = Monthly * = Notify Dealer Y = Yearly if Repair is Needed. FUEL Fuel lines and connections*XM LUBRICATION Oil level XM Oil X AFTER BREAK-IN, AND Y Oil filter X AFTER BREAK-IN, AND Y COOLING Encl

Summary of the content on the page No. 20

Section 5 — Troubleshooting Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators 5.1 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION The engine will not crank. 1. Fuse blown. 1. Replace 15A fuse in generator control panel. 2. Loose, corroded or defective 2. Tighten, clean or replace battery cables. as necessary. 3. Defective starter contactor. (7 kW) 3. * 4. Defective starter motor. 4. * 5. Dead Battery. 5. Charge or replace battery. The engine cranks but 1. Out of fuel. 1. Replenish fuel. will n


Alternative user manuals
# User manual Category Download
1 Bryant ASPAS1BBA007 ASPAS1BBA012 ASPAS1BBA015 User manual Portable Generator 0
2 Bryant ASPCA1BBL040 User manual Portable Generator 1
3 Bryant ASPAS1BBA015 User manual Portable Generator 2
4 Bryant Automatic Standby Generator ASPAS1BBA007 User manual Portable Generator 3
5 Bryant Liquid-Cooled, Prepackaged Standby Generators ASPAS1BBL025 User manual Portable Generator 0
6 Bryant ASPCS1BBL040 User manual Portable Generator 0
7 Bryant ASPAX1BBA015 User manual Portable Generator 1
8 Bryant HOME STANDBY ASPAS1BBL040 User manual Portable Generator 0
9 Bryant ASPAS1BBL015 User manual Portable Generator 0
10 ACDelco AC-G0005 User manual Portable Generator 1
11 ACDelco AC-G0002 User manual Portable Generator 0
12 ACDelco AC-G0004 User manual Portable Generator 3
13 AEG 2.33 2 User manual Portable Generator 3
14 ACDelco AC-G0003 User manual Portable Generator 0
15 Agilent Technologies 669xA User manual Portable Generator 1