Armstrong World Industries ACUM84 user manual

User manual for the device Armstrong World Industries ACUM84

Device: Armstrong World Industries ACUM84
Category: Portable Generator
Manufacturer: Armstrong World Industries
Size: 2.68 MB
Added : 9/23/2014
Number of pages: 34
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Armstrong World Industries ACUM84. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Armstrong World Industries ACUM84.

For your convenience

If looking through the Armstrong World Industries ACUM84 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Armstrong World Industries ACUM84 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Armstrong World Industries ACUM84 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Armstrong World Industries ACUM84 User manual - Online PDF
Advertisement
« Page 1 of 34 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Armstrong World Industries ACUM84 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Armstrong World Industries ACUM84. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



Date: 10/01/07
OWNERS MANUAL
CUMMINS SERIES:
MODELS ACUM65, ACUM84, ACUM110, ACUM140,
ACUM185, ACUM210
AR-EXP-CUMMINS-07-00 OWNERS MANUAL

Summary of the content on the page No. 2

Page 2 SAVE THESE INSTRUCTIONS This manual contains important instructions regarding for all Armstrong Power Systems LLC power generator Models. The information contained here must be followed during installation and maintenance of the genera- tor and batteries. Keep this manual with the equipment. If the equipment is traded or sold, give the manual to the new owner. You are now the owner of a Armstrong Power generator powered by CUMMINS engine. All our components keep the highest

Summary of the content on the page No. 3

WARRANTY CERTIFICATE The warranty period for the power generator begins on the date of sale and continues for a period of 2 years or 1500 hours (what ever comes first). Responsibilities: a) As the owner, you are responsible for the performance of the required maintenance listed on your operators manual. b) Armstrong Power may deny your warranty coverage if your engine or part has failed due to abuse, neglect, improper maintenance or unapproved modifications. Coverage: Armstrong Power warran

Summary of the content on the page No. 4

Page 4 AR-EXP-CUMMINS-07-00 OWNERS MANUAL

Summary of the content on the page No. 5

Page 5 1. INTRODUCTION This manual provides general safety information for installing, operating and maintenance of Armstrong Power equipments. The purchaser should comply with the instructions and information in this manual, and is strongly ad- vised that all personnel to be associated with the equipment supplied should be made familiar with the information contained herein. It is essential that the personnel engaged in the installation, commissioning and maintenance of thi

Summary of the content on the page No. 6

Page 6 3. FIRE AND EXPLOSION Risk of serious injuries or death Fuels and fumes associated with generating sets can be flammable and potentially explo- sive. Proper care in handling these materials can dramatically limit the risk of fire or explo- sion. However, safety dictates that fully charged BC and ABC fire extinguishers are kept on hand. Personnel must know how to operate them. • The acids in the battery can cause explosion. • Avoid any contact between the tools and

Summary of the content on the page No. 7

Page 7 5. MECHANICAL The generating set is designed with guards for protection from moving parts. Care must still be taken to protect personnel and equipment from other mechanical hazards when working around the generating set. • Do not attempt to operate the generating set with safety guards removed. While the generating set is running do not attempt to reach under or around the guards to do maintenance or for any other reason. • Keep hands, arms, long hair, loose clothin

Summary of the content on the page No. 8

Page 8 7. NOISE Generating sets that are not equipped with sound attenuating enclosures can produce noise levels in excess of 105 dBA. Prolonged exposure to noise levels above 85 dBA is hazardous to hearing. • Ear protection must be worn when operating or working around an operating set. 8. ELECTRICAL Safe and efficient operation of electrical equipment can be achieved only if the equip- ment is correctly installed, operated and maintained. • The ge

Summary of the content on the page No. 9

Page 9 9. FIRST AID FOR ELECTRIC SHOCK Identification / look out for: • Unconsciousness and Burns • Establish site of entry and exit of electric shock What to do: • Switch off the main switch. • Break the contact between electrical source and patient using dry non-conductive object like wooden stick. • Call for help. • If breathing and heartbeat has stopped begin CPR 1. CALL Check the victim for unresponsiveness. If there is no response, Call 911 and return to the

Summary of the content on the page No. 10

Page 10 10. SPECIAL CONSIDERATIONS FOR BATTERY CAUTION – The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corrosive. The following procedures are to be observed: 1) Wear full eye protection and protective clothing, 2) Where electrolyte contacts the skin, wash it off immediately with water, 3) Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention, and 4) Spilled

Summary of the content on the page No. 11

Page 11 GENERATING SET INSTALLATION AR-EXP-CUMMINS-07-00 OWNERS MANUAL

Summary of the content on the page No. 12

Page 12 roof and an outside security enclosure (fence) to pro- 1. LOCATION tect the unit from vandalism, birds, rodents, and other small animals is recommended. The generating set sub base tank or frame (if it’s the case) • The Gen-Set generates heat while running. Installing is specifically designed for ease of moving the set. Improper the Gen-Set in a tightly enclosed building or shed is not handling can cause serious damage to the generator and recommended. The site must provide

Summary of the content on the page No. 13

The typical ratio of cement, sand, and aggregate is Page 13 1:2:3 with a maximum 4 inch (102 mm) slump and 28 day compressive strength of 2500 psi (173 kPa). • A generator can typically be mounted to a combustible floor or roof, dependent upon code, however, the sur- face beneath the engine and beyond the engine to a minimum distance of 12 inches (305 mm) must be covered with a non combustible insulation and a mini- mum of 24 gage sheet metal between the insulation Figure 1- Single Ped

Summary of the content on the page No. 14

Page 14 haust piping becomes extremely hot during operation and 4. ELECTRICAL SYSTEM remains hot for a long time after shutdown. For that reason, There are a number of different generator systems and the following precautions are necessary: typical loads in the context of electrical systems. Most sys- tems, unless they contain automated switch gear, have a • Avoid contact with hot engines, exhaust manifolds, means of disconnect between the generator and the exhaust piping and mufflers

Summary of the content on the page No. 15

Page 15 6. INSTALLATION CHECKLIST BATTERY INSTALLATION  Battery is connected properly.  Recommended battery is installed.  Cables are clean and tight.  Terminals are coated with anti-corrosion grease, and terminal covers are positioned. FUEL SYSTEM  Complies with local and NFPA codes.  Fuel is connected and checked for leaks.  Correct fuel pressure (11-14 inches of water (0.6 psi) at all load ranges).  Load block adjusted for maximum power for natural gas fuel. LOC

Summary of the content on the page No. 16

Page 16 AR-EXP-CUMMINS-07-00 OWNERS MANUAL

Summary of the content on the page No. 17

Page 17 GENERATING SET OPERATION AND MAINTENANCE AR-EXP-CUMMINS-07-00 OWNERS MANUAL

Summary of the content on the page No. 18

Page 18 6. PRE-OPERATION CHECK the generator’s main circuit breaker to its ON (or closed) position. Before starting, complete the following: Proceed with caution! Generator power voltage 1. Set the generator's Start/stop switch to the is now supplied to the transfer switch. Contact Stop position. with live transfer switch parts will result in dangerous and possibly fatal electrical shock. 8. Connect an accurate AC voltmeter and an AC frequency meter across transfer switch ter

Summary of the content on the page No. 19

Page 19 generator. • After about six seconds, the switch should transfer loads back to the utility power source. 8. Turn ON electrical loads. Apply an electrical load equal to • About one minute after retransfer, the engine should the full rated wattage/amperage capacity of the installed shut down. generator. Check the installation and application data charts for any 9. Connect an accurate AC frequency meter across terminal additional information. lugs . Voltage should be +/-

Summary of the content on the page No. 20

ACUM65 INSTALLATION AND APPLICATION Type of Operation and Application Item Units 60 Hz 50 Hz Prime Standby Prime Standby Rated Speed rpm 1800 1500 Gross Engine Output bhp (kWm) 90 (67) 99 (74) 77 (58) 85 (64) Engine BMEP psi (kPa) 165 (1137) 182 (1255) 169 (1165) 187 (1289) Mean Piston Speed Ft/s (m/s) 23.6 (7.2) 19.66 (6.0) Ambient Air Temperature °F (°C) 122 (50) Engine Heat Reject to Coolant BTU/min (kW) 2035 (35.8) 2240 (39.3) 1750 (30.8) 1995 (35.0) Coolant C


Alternative user manuals
# User manual Category Download
1 Armstrong World Industries ACUM185 User manual Portable Generator 4
2 Armstrong World Industries ACUM140 User manual Portable Generator 4
3 Armstrong World Industries ACUM65 User manual Portable Generator 5
4 Armstrong World Industries ACUM110 User manual Portable Generator 6
5 Armstrong World Industries ACUM210 User manual Portable Generator 4
6 ACDelco AC-G0005 User manual Portable Generator 1
7 ACDelco AC-G0002 User manual Portable Generator 0
8 ACDelco AC-G0004 User manual Portable Generator 3
9 AEG 2.33 2 User manual Portable Generator 3
10 ACDelco AC-G0003 User manual Portable Generator 0
11 Agilent Technologies 669xA User manual Portable Generator 1
12 Agilent Technologies 66309B User manual Portable Generator 5
13 Agilent Technologies 665xA User manual Portable Generator 1
14 Agilent Technologies 83622B User manual Portable Generator 2
15 Agilent Technologies 8360 User manual Portable Generator 1