Vulcan-Hart 1024 user manual

User manual for the device Vulcan-Hart 1024

Device: Vulcan-Hart 1024
Category: Fondue Maker
Manufacturer: Vulcan-Hart
Size: 1.13 MB
Added : 10/12/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Vulcan-Hart 1024. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Vulcan-Hart 1024.

For your convenience

If looking through the Vulcan-Hart 1024 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Vulcan-Hart 1024 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Vulcan-Hart 1024 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Vulcan-Hart 1024 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Vulcan-Hart 1024 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Vulcan-Hart 1024. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION &
OPERATION MANUAL
1024,1036,1048 CHEESEMELTER
MODELS
1024C ML-103833
1024W ML-103834
1024P ML-103835
1036C ML-103836
1036W ML-103837
1036P ML-103838
1048C ML-103839
Canadian ML-126600
1048W ML-103840
Canadian ML-126602
1048P ML-103841
Canadian ML-126601
Model 1024
In U.S.A.: In Canada:
VULCAN-HART COMPANY HOBART FOOD EQUIPMENT GROUP CANADA
P.O. BOX 696 190 RAILSIDE ROAD
LOUISVILLE, KY NORTH YORK, ONTARIO
40201-0696 M3A 1B1
TEL.: 502-778-2791 TEL.: 1-800-444-4764
F33225B (599) PRINT

Summary of the content on the page No. 2

– 2 –

Summary of the content on the page No. 3

TABLE OF CONTENTS GENERAL............................................................................................................................................. 4 Specifications ........................................................................................................................... 4 INSTALLATION .................................................................................................................................... 5 Unpacking ................................

Summary of the content on the page No. 4

OPERATION & INSTALLATION MODELS 1024,1036,1048 CHEESEMELTERS PLEASE KEEP THIS MANUAL FOR FUTURE USE GENERAL Vulcan-Hart Cheesemelters are produced with quality workmanship and material. Proper installation, usage, and maintenance of your cheesemelter will result in many years of satisfactory performance. Thoroughly read this entire manual and carefully follow all of the instructions provided. The cheesemelter is designed for either countertop or wall mounted operation, and is also available in a

Summary of the content on the page No. 5

INSTALLATION UNPACKING This cheesemelter was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking, check for possible shipping damage. If the cheesemelter is found to be damaged, save the packaging material and contact the carrier within 7 days of delivery. 1. Unpack cheesemelter and remove all packaging materials. • Heater and legs on countertop and pass through models, and hea

Summary of the content on the page No. 6

INSTALLATION CODES AND STANDARDS The cheesemelter must be installed in accordance with: In the United States of America: 1. State and local codes. 2. National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. In Canada: 1. Local codes. 2. Canadian Electric Code, CSA C22.1 (latest edition). Copies may be obtained from The Canadian Standard Association, 178 Rexdale Blvd., Etobicoke, Ontario, Ca

Summary of the content on the page No. 7

– 7 –

Summary of the content on the page No. 8

HEATER INSTALLATION 1. Push one end of the heater into one socket as far as it will go. 2. Swing the other end of heater up until it lines up with the opposite socket. 3. Release heater and it will snap into place. 4. Grasp the heater and move it back and forth to ensure that it is centered correctly. 5. Rotate the heater clockwise, then counterclockwise, to ensure that it is seated correctly. RACK INSTALLATION 1. Insert the rack by placing the left pivot point just behind the switch slide. 2. L

Summary of the content on the page No. 9

ELECTRICAL CONNECTIONS WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES. WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE YOU ARE WORKING ON THE CIRCUIT. Two 1" (25 mm) knockouts are provided at the left rear for conduit installation. The terminal block and grounding lug are located behind the access cover on the left side. – 9 –

Summary of the content on the page No. 10

OPERATION WARNING: THE CHEESEMELTER AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN OPERATING, CLEANING, OR SERVICING THE CHEESEMELTER. 1. Push the main switch to ON. • Pilot lights. • Cooling fan runs. 2. Place the product on the front of the rack. The heaters will automatically come on full power. • If the heaters do not come on full power when the product is placed on the rack: a. Be sure that the product is on the front half of the rack. The rack is balanced to trip the actuating switch, but th

Summary of the content on the page No. 11

TROUBLESHOOTING IF THE CHEESMELTER BLOWS A FUSE OR TRIPS A CIRCUIT BREAKER 1. Check the capacity of the circuit. 2. Contact your local Hobart Food Equipment Group office. IF THE HEATERS DO NOT LIGHT 1. If the pilot light does not come on, and the cooling fan does not run, check for a blown fuse or an open circuit breaker. 2. If the pilot light is lit, and the cooling fan is running, but the heaters do not light, the cheesemelter may be in standby. When cheesemelter is in standby with no product

Summary of the content on the page No. 12

NOTES – 12 –

Summary of the content on the page No. 13

MODE D’EMPLOI SALAMANDRES 1024, 1036 ET 1048 MODÈLES 1024C ML-103833 1024W ML-103834 1024P ML-103835 1036C ML-103836 1036W ML-103837 1036P ML-103838 1048C ML-103839 Canada ML-126600 1048W ML-103840 Canada ML-126602 1048P ML-103841 Canada ML-126601 Modèle 1024 Aux É.-U. : Au Canada : VULCAN-HART COMPANY GROUPE HOBART CANADA ÉQUIPEMENT ALIMENTAIRE P.O. BOX 696 190 RAILSIDE ROAD LOUISVILLE, KY NORTH YORK (ONTARIO) 40201-0696 M3A 1B1 TÉL. : (502) 778-2791 TÉL. : 1 800 444-4764 F33225B (599) IMPRIMÉ

Summary of the content on the page No. 14

– 2 –

Summary of the content on the page No. 15

TABLE DES MATIÈRES GÉNÉRALITÉS .................................................................................................................................... 4 Caractéristiques ....................................................................................................................... 4 INSTALLATION .................................................................................................................................... 5 Déballage......................................

Summary of the content on the page No. 16

Installation et fonctionnement SALAMANDRES 1024, 1036 ET 1048 DOCUMENT À CONSERVER EN CAS DE BESOIN. GÉNÉRALITÉS Les appareils Vulcan sont fabriqués avec le plus grand soin et à partir des meilleurs matériaux. Leur installation, utilisation et entretien appropriés permettront d’en obtenir un rendement optimal pendant de nombreuses années. On recommande de lire ce manuel au complet et de suivre attentivement toutes les instructions. Ces appareils s’installent sur un comptoir ou au mur et sont au

Summary of the content on the page No. 17

INSTALLATION DÉBALLAGE Cet appareil a été inspecté avant de quitter l’usine. En acceptant de livrer cette marchandise, le transporteur en assume l’entière responsabilité jusqu’à la livraison. Immédiatement après avoir déballé l’appareil, vérifier s’il n’a pas été endommagé lors du transport. En cas de dommages, conserver le matériel d’emballage et aviser le transporteur dans les sept jours suivant la date de réception. 1. Déballer l’appareil et enlever tout le matériel d’emballage. • L’élémen

Summary of the content on the page No. 18

CODES D’INSTALLATION ET NORMES L’installation de ces salamandres doit se faire selon les codes suivants : Aux États-Unis : 1. Codes locaux. 2. Norme ANSI/NFPA n° 70 (dernière édition) du National Electrical Code disponible auprès de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Au Canada : 1. Codes locaux. 2. Norme CSA-C22.1 (dernière édition) du Code canadien de l’électricité dont on peut se procurer un exemplaire auprès de l’Association canadienne de normalisati

Summary of the content on the page No. 19

PANNEAU ARRIÈRE ISOLANT APPAREIL TIRE-FONDS VIS DE RETENUE DU PANNEAU ARRIÈRE – 7 –

Summary of the content on the page No. 20

INSTALLATION DES ÉLÉMENTS CHAUFFANTS 1. Enfoncer une des extrémités de l’élément chauffant aussi loin que possible dans une douille. 2. Aligner l’autre extrémité avec la douille opposée. 3. Relâcher l’élément chauffant et il s’enclenche en place. 4. Saisir l’élément et lui imprégner un mouvement de va-et-vient pour s’assurer qu’il est bien centré. 5. Tourner l’élément dans le sens des aiguilles d’une montre, puis dans le sens contraire pour s’assurer qu’il est bien en place. INSTALLATION DE LA G


Alternative user manuals
# User manual Category Download
1 Vulcan-Hart 1024W ML-103834 User manual Fondue Maker 0
2 Vulcan-Hart 1036P ML-103838 User manual Fondue Maker 0
3 Vulcan-Hart 1036W ML-103837 User manual Fondue Maker 0
4 Vulcan-Hart 1036C ML-103836 User manual Fondue Maker 0
5 Vulcan-Hart 1024P ML-103835 User manual Fondue Maker 0
6 Vulcan-Hart 1048C ML-103839 User manual Fondue Maker 0
7 Vulcan-Hart 1048P ML-103841 User manual Fondue Maker 0
8 Vulcan-Hart 1048W ML-103840 User manual Fondue Maker 0
9 Vulcan-Hart ICM24 User manual Fondue Maker 0
10 Vulcan-Hart CMR34 User manual Fondue Maker 0
11 Vulcan-Hart 1048 User manual Fondue Maker 0
12 Vulcan-Hart 1036 User manual Fondue Maker 2
13 Vulcan-Hart 52480 User manual Fondue Maker 0
14 Vulcan-Hart ICM24 ML-52470, 52476, ICM36 ML-52471, 52477, ICM48 ML-52472, 52478, ICM60 ML-52743,52479, ICM72 ML-52474, 52480 User manual Fondue Maker 1
15 Vulcan-Hart ICM72 User manual Fondue Maker 0
16 APW Wyott CMP-36 User manual Fondue Maker 0
17 APW Wyott CMC-36 User manual Fondue Maker 0
18 APW Wyott CMW User manual Fondue Maker 0
19 Accton Technology POWER-3004E User manual Fondue Maker 0
20 APW Wyott CMP User manual Fondue Maker 0