Frigidaire FRS09PYW1 user manual

User manual for the device Frigidaire FRS09PYW1

Device: Frigidaire FRS09PYW1
Category: Yard Vacuum
Manufacturer: Frigidaire
Size: 1.52 MB
Added : 7/5/2014
Number of pages: 25
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Frigidaire FRS09PYW1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Frigidaire FRS09PYW1.

For your convenience

If looking through the Frigidaire FRS09PYW1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Frigidaire FRS09PYW1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Frigidaire FRS09PYW1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Frigidaire FRS09PYW1 User manual - Online PDF
Advertisement
« Page 1 of 25 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Frigidaire FRS09PYW1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Frigidaire FRS09PYW1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

All about the
Installation
of your
Split Type Room Air Conditioner
Model(indoor/outdoor):
FRS09PYW1/FRS09PYC1
FRS12PYW1/FRS12PYC1
FRS184YW2/FRS184YC2
FRS18PYW2/FRS18PYC2
FRS224YW2/FRS224YC2
FRS22PYW2/FRS22PYC2
www.frigidaire.com USA 1-866-942-1567 www.frigidaire.ca Canada 1-866-942-1567

Summary of the content on the page No. 2

Safety precautions This appliance must be installed by a qualified licensed HVAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician. DANGER! Avoid Serious Injury CAUTION! Avoid Injury or or Death damage to the unit or other property 1. Do not attempt to install the split air conditioner by yourself. 1. Provide occasional ventilation 2. This air conditioner contains no during use. Do not direct airflow at user-serviceab

Summary of the content on the page No. 3

To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. 1. Connect with the power properly. Otherwise, it may cause electric shock or fire due to excess heat generation. 2. Always ensure effective grounding. No grounding may cause electric shock. 3. Disconnect the power if strange sounds, smell,

Summary of the content on the page No. 4

11.Do not open the unit during operation. It may cause electric shock or injury. 12.Do not drink water drained from air conditioner. It contains contaminants and could make you sick. 13.Do not disassemble or modify unit. It may cause failure of appliance and electric shock. 14.When the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury. 15.When the unit is to be cleaned, switch off, and turn off the circuit breaker. Do not clean unit when po

Summary of the content on the page No. 5

Choosing the installation site Installation Warnings 1. Carefully read the installation manual before beginning. 2. Follow each step as shown. 3. Observe all local, state and national electric codes. This appliance must be installed by a qualified licensed HVAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician. 4. Pay attention to danger and safety notices Precautions for Installation Installation a

Summary of the content on the page No. 6

Indoor Unit inside wall, always leaving a space of 1. The unit must be installed at a site that does not obstruct the flow of at least 6" between the top of the air. indoor unit and the ceiling. 2. The site must support the weight of 8. The site must allow for the easy the indoor unit. removal of the connector pipe and 3. The site must be easily accessible drain hose. for maintenance and replacement 9. The unit must be installed at a site of the air filter. protected from direct su

Summary of the content on the page No. 7

Summary of the content on the page No. 8

1 More than 6" 3 Indoor unit More than 6" 6 More than 6" Air filter 4 5 More than 1.65' More than 1' A More 8 than 1.65' 7 6 B C More than 6.6' Outdoor unit 2 Attention 1. This illustration is for explanation purposes only. 2. Copper tubes must be insulated independently Parts list 10

Summary of the content on the page No. 9

Indoor unit installation Installation plates and dimensions 6" or more from Installation plate the ceiling Indoor unit outline 6" or more 6" or more from the wall from the wall Refrigerant pipe Refrigerant pipe hole (right) Ø 2.56" hole (right) Ø 2.56" 3.39" 3.39" A < 12000 Btu's (A:33.31" B:10.83") 6" or more from the ceiling Installation plate A Indoor unit outline 6" or more 6" or more from the wall from the wall Refrigerant pipe Refrigerant pipe hole (right) Ø 2.56" hole (right) Ø

Summary of the content on the page No. 10

6" or more from the ceiling Installation plate A Indoor unit outline 6" or more from the wall 6" or more from the wall 1.97'' 1.97'' Refrigerant pipe Refrigerant pipe hole (right) Ø 2.56" hole (right) Ø 2.56" 3.94'' 4.88'' =21500 Btu's (A:39.69" B:12.40") Fixing the Installation Plate 1. Install the installation plate horizontally over the structural Attention parts on the wall using the spaces indicated on the plate, as shown Fit the Installation Plate and drill holes in the figure

Summary of the content on the page No. 11

Connective pipe and drainage installation Connective pipe Pipe cover Pipe Pipe cover (right) holder (left) 1. For the left-hand and right-hand piping, remove the pipe cover from the side panel. The pipe cover Left piping must be kept as it may be used when relocating the air conditioner to any other place. Rear left Rear right Right piping piping piping 2. For the rear-right-hand and rear-left- Connective hand piping, install the piping as Indoor unit pipe outline shown in the sideward fig

Summary of the content on the page No. 12

3. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. Get it out after finish piping. 4. Push the lower part of the indoor unit up on the wall, Then move the indoor unit from side to side, up and down to check if it is Cushioning hooked securely. material Piping and wrapping Ponding box 1. Bundle the tubing, connecting Indoor unit cable, and drain hose with tape securely and evenly as shown Cable Pipe room in the sid

Summary of the content on the page No. 13

Outdoor unit installation 1. Install the outdoor part of the unit on a rigid surface to avoid excess noise and vibration. 2. Direct the air vent toward an area without obstacles. 3. Install the unit at the site where it is exposed to as little wind as possible, especially in areas where it is frequently windy. 4. If the installation site is exposed to heavy winds, such as in coastal areas, place the unit along the widest part of the wall or use protective plates. 5. Be sure there

Summary of the content on the page No. 14

Air inlet Settlement of outdoor unit Anchor the outdoor unit tightly and horizontally on a concrete or rigid Air inlet mount with a bolt and nut 0.39" or 0.32" diameter (Purchased separately). Air outlet A ft) B( ft) Outdoor unit dimension ft(WxHxD) 1 ' ' Condensate drainage of outdoor unit (no for cooling only) The condensate and defrosting water formd during heating in the outdoor unit can be properly discharged by drainage pipe . Installation method:Insert the drain connect

Summary of the content on the page No. 15

Refrigerant piping connection Unit comes with 16.4' tubing bundle. It is not recommended to cut. If too long, loop for excess. Note: Keep original bend so not kinking of the tube occurs. Flaring work Main cause for refrigerant leakage is Pipe due to defect in the flaring work. Carry out correct flaring work using the following procedure: 1. Cut the pipes and the cable. A) Use the piping kit accessory or Correct Wrong pipes purchased locally. Oblique Roughness Burr B) Measure the distance be

Summary of the content on the page No. 16

4. Flaring work. Firmly hold copper pipe in a Bar die in the dimension shown in Copper pipe the table below. Handle A (inch) OUTER DIAMETER (inch) Yoke Min. Max. Red arrow mark 0.028 1/4 0.051 0.039 3/8 0.063 0.039 1/2 0.071 Clamp 0.087 5/8 0.095 handle Connection Adjustment 1. Align the pipes to be connected. Caution: Excessive twisting may 2. Screw the flare nut with your break the nut, depending on the fingers, and then tighten it with installation conditions. a spanner and torque wren

Summary of the content on the page No. 17

Power voltage should meet the requirements in the following table. 3. Over current protection and circuit disconnect should meet the requirements in the following table and the applicable local and national electrical codes. Electrical Data Table System Operating Compressor Outdoor Fan Indoor Fan Max. Fuse/Circuit MIN. Circuit Capacity Voltage Voltage Ampacity Breaker (BTU) Volts-Ph.- Output Output (MCA) Amps(MOCP) (Min/Max) RLA LRA FLA HP Volts FLA HP Freq Watts Watts 9K

Summary of the content on the page No. 18

1.57" 0.39" Connect the cable to the indoor unit Electrical box cover 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type designation 16AWG or heavier cord. 3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw. 4. Ensure the colour of wires of outdoor unit and the terminal Nos. are the

Summary of the content on the page No. 19

1.

Summary of the content on the page No. 20

Caution After the confirmation of the above conditions, prepare the wiring as follows: 1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2. The screws which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they


Alternative user manuals
# User manual Category Download
1 Frigidaire FRA08EHTI User manual Yard Vacuum 0
2 Frigidaire FRS12PYW1 User manual Yard Vacuum 0
3 Frigidaire FRS09PYC1 User manual Yard Vacuum 0
4 Frigidaire FRS184YC2 User manual Yard Vacuum 0
5 Frigidaire FRS12PYC1 User manual Yard Vacuum 0
6 Frigidaire FRS18PYC2 User manual Yard Vacuum 0
7 Frigidaire FRS18PYS2 User manual Yard Vacuum 0
8 Frigidaire FRS18PYW2 User manual Yard Vacuum 0
9 Frigidaire FRS184YW2 User manual Yard Vacuum 0
10 Abbott Laboratories 11781-04 User manual Yard Vacuum 5
11 Agilent Technologies 6800 User manual Yard Vacuum 1
12 Agilent Technologies 6813B User manual Yard Vacuum 2
13 Agilent Technologies 1680 User manual Yard Vacuum 1
14 Agilent Technologies e4418b User manual Yard Vacuum 57
15 Agilent Technologies 437B User manual Yard Vacuum 49