White Rodgers 36j27-554 user manual

User manual for the device White Rodgers 36j27-554

Device: White Rodgers 36j27-554
Category: Offroad Vehicle
Manufacturer: White Rodgers
Size: 3.6 MB
Added : 5/30/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for White Rodgers 36j27-554. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with White Rodgers 36j27-554.

For your convenience

If looking through the White Rodgers 36j27-554 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual White Rodgers 36j27-554 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual White Rodgers 36j27-554 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
White Rodgers 36j27-554 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual White Rodgers 36j27-554 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to White Rodgers 36j27-554. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

36J27-554
DSI and HSI Modulating Combination Gas Valve
INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
The 36J27 combination gas valve is designed for
direct spark ignition (DSI) and hot surface ignition
(HSI) system applications. This control is equipped
with redundant and main solenoid valves that control
gas flow to the main burners, a pressure re

Summary of the content on the page No. 2

MOUNTING POSITIONS UPRIGHT, OR 0° TO 90° FROM UPRIGHT Upright (inlet left) Vertical (inlet bottom) Vertical (inlet top) 90° from Upright (inlet left) Vertical (inlet bottom) Vertical (inlet top) 90° from Upright (inlet bottom) Fig. 2 – Valve Mounting 3.000 MAX. SWING RADIUS Upright Length .................................. 4.75" (facing left) Width ................................... 2.38" Height .................................. 4.58" Swing Radius ........................ 3.00" Swing Radius

Summary of the content on the page No. 3

MOUNTING POSITIONS PRECAUTIONS DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING PRECAUTIONS. If you do not follow these instructions exactly, a fire or explosion WARNING ! may result, causing property damage, personal injury or loss of life. 1. Failure to turn off electric or main gas supply 5. Do not use a gas valve which appears to to heating system could cause personal be damaged. A damaged valve may cause injury and/or property damage by shock, personal injury and/or property dam

Summary of the content on the page No. 4

INSTALLATION 1. Turn off electrical power to the system at the 6. If you are using a vise or open-end wrench to fuse box or circuit breaker. Also turn off the hold the valve while installing piping, do not main gas supply. tighten excessively, as this may damage the valve. (Torque: 375 in-lb maximum.) Do not 2. If replacing an existing valve, disconnect all cross-thread during installation as this may plumbing and electrical connections from the damage the valve. old control. 7. See SY

Summary of the content on the page No. 5

INSTALLATION ELECTRICAL 5 PIN CONNECTOR PIN 1 LOCATION INLET PRESSURE TAP POST REGULATOR OUTLET VENT PRESSURE VALVE INLET TAP POST VALVE OUTLET Electrical 5 PIN Connector Pin Out PIN 5 - TH - Main Valve 24 VAC (top pin, with the cover pointing up) PIN 4 - TR - Ground PIN 3 - TX - Communication to IFC PIN 2 - RX - Communication to Stepper PIN 1 - TH - Board 24VAC (bottom pin, with the cover pointing up) Fig. 5 – 36J27 Valve Features ADJUSTMENT The gas valve outlet pressure was pre-adjust

Summary of the content on the page No. 6

LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion WARNING ! may result, causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped • If you cannot reach your gas supplier, call the with an ignition device which automatically lights fire department. the burner. Do not try to light the burner by hand. C. Use only your hand to move the gas control B. BEFORE OPERA

Summary of the content on the page No. 7

NOTES 7

Summary of the content on the page No. 8

White-Rodgers is a business of Emerson Electric Co. The Emerson logo is a www.white-rodgers.com trademark and service mark of Emerson Electric Co. www.emersonclimate.com

Summary of the content on the page No. 9

White-Rodgers est une entreprise d’Emerson Electric Co. Le logo d’Emerson est une marque de commerce et une marque de www.white-rodgers.com service d’Emerson Electric Co. www.emersonclimate.com

Summary of the content on the page No. 10

REMARQUES 7

Summary of the content on the page No. 11

DIRECTIVES D’ALLUMAGE POUR VOTRE SÉCURITÉ, VEUILLEZ LIRE CE QUI SUIT AVANT L’UTILISATION Si ces directives ne sont pas respectées à la lettre, un incendie ou une explosion pourrait survenir et causer des dommages matériels, des blessures ou des pertes de vie. A. Cet appareil n’est pas doté d’une veilleuse • Si vous ne pouvez pas joindre le fournisseur de d’allumage. Il est pourvu d’un dispositif d’allumage gaz, appelez les pompiers. qui allume automatiquement le brûleur. Ne tentez C. Servez

Summary of the content on the page No. 12

INSTALLATION Disposition des broches du connecteur électrique à 5 broches BROCHE 5 - TH - 24 V c.a. de la vanne principale (broche supérieure lorsque le couvercle pointe vers le haut) BROCHE 4 - TR - mise à la terre BROCHE 3 - TX - communication avec l’IFC BROCHE 2 - TX - communication avec le moteur pas-à-pas BROCHE 1 - TH - 24 V c.a. de la carte (broche inférieure lorsque le couvercle pointe vers le haut) Fig. 5 – 36J27 Caractéristiques de la vanne RÉGLAGE La pression à l’entrée de la vann

Summary of the content on the page No. 13

INSTALLATION 1. Coupez l’alimentation électrique au système au 6. Si vous utilisez une pince-étau ou une clé à fourche niveau du panneau de fusibles ou de disjoncteurs. pour retenir la vanne pendant l’installation du Coupez également l’alimentation principale en gaz. tuyau, ne serrez pas de façon excessive, car cela 2. Si vous remplacez une vanne existante, débranchez pourrait endommager la vanne. (Couple de serrage : 375 po-lb au maximum.) Évitez de fausser le filetage tous les raccordem

Summary of the content on the page No. 14

PRÉCAUTIONS POSITIONS DE MONTAGE NE COMMENCEZ PAS L’INSTALLATION AVANT D’AVOIR LU LES PRÉCAUTIONS SUIVANTES. Si ces directives ne sont pas respectées à la lettre, un incendie ou une explosion pourrait survenir et causer des dommages matériels, des blessures ou des pertes de vie. 1. Le fait de ne pas couper l’alimentation électrique 5. N’utilisez pas une vanne à gaz qui semble être ou l’alimentation principale en gaz du système endommagée. Une vanne endommagée peut de chauffage pourrait e

Summary of the content on the page No. 15

POSITIONS DE MONTAGE À LA VERTICALE OU ENTRE 0° ET 90° PAR RAPPORT À LA VERTICALE Debout (entrée à gauche) Vertical (entrée au bas) Vertical (entrée sur le dessus) 90 degrés de la position debout (entrée à gauche) Vertical (entrée au bas) 90 degrés de la position debout Vertical (entrée sur le dessus) (entrée au bas) Fig. 2 – Montage du robinet Longueur .................................... 4,75 po Debout Largeur ....................................... 2,38 po (face vers l’entrée) Hauteur

Summary of the content on the page No. 16

36J27-554 Vanne modulatrice à gaz combinée à ADE et à ASC DIRECTIVES D’INSTALLATION VEUILLEZ LIRE ET RESPECTER SOIGNEUSEMENT TOUTES LES DIRECTIVES AVANT L’INSTALLATION OU L’UTILISATION DE CET APPAREIL POUR PRÉVENIR LES BLESSURES ET LES DOMMAGES MATÉRIELS. DESCRIPTION La vanne à gaz combinée 36J27 est conçue pour les systèmes à allumage direct par étincelle (ADE) et à allumage par surface chaude (ASC). Cette commande est dotée d’électrovannes principales et redondantes qui contrôlent le d


Alternative user manuals
# User manual Category Download
1 White Rodgers 36C53 User manual Offroad Vehicle 1
2 White Rodgers 36E93-304 User manual Offroad Vehicle 1
3 White Rodgers 37-6658D User manual Offroad Vehicle 1
4 White Rodgers 36J27-554 User manual Welding Consumables 0
5 AB Soft Snowplow 760LT User manual Offroad Vehicle 0
6 AB Soft Snowplow 760HD User manual Offroad Vehicle 0
7 AB Soft Snowplow 860HD User manual Offroad Vehicle 0
8 Arctic Cat A2006TBM4BUSR User manual Offroad Vehicle 42
9 AB Soft Snowplow 800HD User manual Offroad Vehicle 3
10 Arctic Industries Bearcat ATV 2X4 97A2A-AP User manual Offroad Vehicle 0
11 Barbie LIL' TRAIL RIDER K0451 User manual Offroad Vehicle 0
12 Can-Am BOMBARDIER DS650 User manual Offroad Vehicle 470
13 Craftsman A2006ABH4AUSR User manual Offroad Vehicle 0
14 Five Star 150 User manual Offroad Vehicle 1
15 Craftsman A2006ABH4AUSG User manual Offroad Vehicle 0