Summary of the content on the page No. 1
Exe/Devon/County Double
Freestanding
Double Sided Stove
USER INSTRUCTIONS
For use in Great Britain and Eire.
This product is suitable for use in the stated countries. To install the
product in other countries it is essential to obtain translated instructions
and in some cases the product may require modification. Contact Yeoman
Stoves to obtain further information.
Exe Double Double
YM-W9121FL / YM-W9122FL
Devon Single Double
YM-W9211FL / YM-W9212FL / YM-W9211LC / YM-W9212LC / YM-W9212HC
Devo
Summary of the content on the page No. 2
FOR YOUR RECORDS To assist us in any Guarantee claim please complete the following information:- Dealer appliance was purchased from Name: ..................................................................................................................................................................................... Address: ..........................................................................................................................................................................
Summary of the content on the page No. 3
SERVICE RECORDS 1st SERVICE 2nd SERVICE Date of Service: ..................................... Date of Service: ..................................... Next Service Due: ................................... Next Service Due: ................................... Signed: ............................................ Signed: ............................................ Dealer’s Stamp/HETAS Registration Number Dealer’s Stamp/HETAS Registration Number 3rd SERVICE 4th SERVICE Date of Service: ........
Summary of the content on the page No. 4
OPERATING INSTRUCTIONS Before using this appliance, please read these instructions fully. SERIAL NUMBER 1. GENERAL 1.8 This number will be required when ordering spare parts or 1.1 This stove is designed for domestic heating and should only making warranty claims. It is found on the DATA PLATE, be used for this purpose, and in accordance with the located on the underside of the stove. manufacturers operating instructions. It should be installed by a competent installer, in accordance with
Summary of the content on the page No. 5
OPERATING INSTRUCTIONS DOOR HANDLE Fuel Consumption Description Kg/Hour Kg/Hour To Open and Close Drop door tool over knob to fit. Wood Briquetted 1 Rotate /2 turn anti-clockwise to open. (300mm long) Smokless Fuel 1 Rotate /2 turn clockwise to close. Exe Double Double 3.5 1.2 Lift up door tool to remove Devon Single Double 3.5 1.6 Devon Double Double 4.5 2.2 County Single Double 5.1 2.3 Open County Double Double 6.9 N/A Open Fuel consumption for canopy models is the same as equivalent flat
Summary of the content on the page No. 6
OPERATING INSTRUCTIONS 4.9 Do not re-fuel the stove above the level of the log guards. 5.10 The ideal control settings to suit the particular installation and personal preferences will be established by experience 4.10 The ideal control settings to suit the particular installation in using the stove. It is not recommended to load large and personal preferences will be established by experience amounts of fuel and burn with the Primary Air Control on in using the stove. low settings for long
Summary of the content on the page No. 7
OPERATING INSTRUCTIONS 8.3 Backpuffing 7. OVER FIRING This is caused by a lack of combustion air entering the firebox causing combustion gases to build up in the firebox 7.1 Do not use the appliance at maximum output for prolonged and periodically ignite as small explosions, causing smoke to periods of time, or over fill the firebox with fuel, as this puff out of the appliance air inlets and other openings. The could result in over-firing. If the connecting fluepipe, problem will often o
Summary of the content on the page No. 8
OPERATING INSTRUCTIONS Damp / Rainy days – These sometimes result in problems STOVE IS PRODUCING TAR: when lighting and maintaining the fire, due to the lower You can recognise this from the following traits: flue temperatures and smaller difference between indoor Very strong pungent smell shortly after the stove is lit and as and outdoor temperatures reducing the flue draught. Also, the stove heats up, glass blackening and, possibly, can be rain water running down the inside of the chimney
Summary of the content on the page No. 9
MAINTENANCE and SERVICING See chart on page 10 for common spare parts referred to in this section. For a complete list of spare parts and accessories contact your Yeoman dealer for the Stovax Fireplace, Stove & Hearth Accessories Brochure or call 01392 474011 4.3 Clean the internal surfaces, baffles and grate parts of the 1. GENERAL CLEANING stove using a wire brush and scraper as required and check the parts for any damage. Replace any damaged parts. Before any cleaning is carried out, all
Summary of the content on the page No. 10
MAINTENANCE and SERVICING This is a list of the maintenance products you may need to use 5. REMOVAL OF THE LOG GUARD Stovax Code Task Product Name number 5.1 Remove the log guards by lifting clear of the supporting Stove glass cleaner 500ml – brackets and rotating to clear the sides of the door 4111 wipe on opening. The stove should not be used without the log Glass Cleaning guard in position. Stove glass cleaner 500ml – 4103 Spray on Preventing build-up Protector (15 sachets) 7002 7025 of
Summary of the content on the page No. 11
MAINTENANCE and SERVICING 6.5 Raise the other end of the baffle plate and attach the baffle 6.14 The baffle system is designed to give safe and efficient extension tubes to the baffle pins, lower the baffle plate operation of the stove. Replace any damaged baffles onto these tubes. immediately. 6.6 Centre the baffle plate. 6.15 Do not modify the baffle system. County (double depth, double sided models only) 7. FITTING A NEW GLASS DOOR Two piece baffle 7.1 To maintain the safe use of your sto
Summary of the content on the page No. 12
MAINTENANCE and SERVICING 7.6 Fit only Yeoman ceramic glass, which is suitable to use in If you require help, your local Yeoman dealer will be able high temperature applications. to carry out all of your service and maintenance requirements for a reasonable cost. 7.7 Using the stove with a damaged door glass could cause dangerous fumes to enter the room, or the stove to overfire, 9. ADJUSTING DOOR CATCH resulting in damage. (ALL MODELS) 8. FITTING A NEW DOOR SEAL 9.1 To adjust the fit of t
Summary of the content on the page No. 13
BASIC SPARE PARTS LIST 2 FOR DEVON/COUNTY SINGLE DOUBLE 1 3 4 5 6 7 11 12 8 13 9 10 FOR DEVON SINGLE DOUBLE FOR COUNTY SINGLE DOUBLE Diagram Part No. Description Diagram Part No. Description No. No. 1 YM-YM00545 Devon/Exe/County 6" Cast 1 YM-YM00545 Devon/Exe/County 6" Cast Flue Spigot Flue Spigot 2 YM-F00088 M6 x 30 Countersunk Allen 2 YM-F00088 M6 x 30 Countersunk Allen Head Screw Head Screw 3 YM-F00019 M8 Roofing Nut 3 YM-F00019 M8 Roofing Nut 4 YM-F00015 M8 Washer 4 YM-F00015 M8 Washer 5
Summary of the content on the page No. 14
BASIC SPARE PARTS LIST 2 FOR EXE/DEVON DOUBLE DOUBLE 1 3 4 5 6 7 11 12 8 13 9 10 FOR EXE DOUBLE DOUBLE FOR DEVON DOUBLE DOUBLE Diagram Part No. Description Diagram Part No. Description No. No. 1 YM-YM00545 Devon/Exe/County 6" Cast 1 YM-YM00545 Devon/Exe/County 6" Cast Flue Spigot Flue Spigot 2 YM-F00088 M6 x 30 Countersunk Allen 2 YM-F00088 M6 x 30 Countersunk Allen Head Screw Head Screw 3 YM-F00019 M8 Roofing Nut 3 YM-F00019 M8 Roofing Nut 4 YM-F00015 M8 Washer 4 YM-F00015 M8 Washer 5 YM-F0
Summary of the content on the page No. 15
BASIC SPARE PARTS LIST 2 FOR COUNTY DOUBLE DOUBLE 1 3 4 5 6 7 11 12 14 8 9 10 13 FOR COUNTY DOUBLE DOUBLE Diagram Part No. Description No. 1 YM-YM00545 Devon/Exe/County 6" Cast Flue Spigot 2 YM-F00088 M6 x 30 Countersunk Allen Head Screw 3 YM-F00019 M8 Roofing Nut 4 YM-F00015 M8 Washer 5 YM-F00005 M8 Roofing Bolt 6 YM-C00008 Baffle Extension Tube 7 YM-C43007CE County Double Double Baffle (2 Per Stove) 8 YM-YM05080 County CE Log Bar 9 YM-YA05422 County Drop In Ashpan Cover 10 YM-YA40658 County Ai
Summary of the content on the page No. 16
BASIC SPARE PARTS LIST FOR EXE/DEVON/COUNTY 1 DOOR 1 10 2 3 4 6 5 9 7 11 8 COMMON PARTS FOR EXE/DEVON/COUNTY FOR EXE 1 DOOR 1 DOOR Diagram Part No. Description Diagram Part No. Description No. No. 1 4670 14mm Rope Seal Black 4 GL0252 Stove Glass Devon/Exe CE 1 Door Large 2 YM-F00001 M5 x 8 Machine Screw 3 YM-C00353 Standard Glass Clip FOR DEVON 1 DOOR 5 4974 3mm Rope Seal Black Diagram Part No. Description 6 YM-F00010 M10 x 35HH Spinner Bolt No. 7 YM-B00030CE Standard Twin Door M18 4 GL0252 S
Summary of the content on the page No. 17
BASIC SPARE PARTS LIST FOR EXE/DEVON/COUNTY 2 DOOR 1 6 18 7 2 3 17 5 4 13 8 14 FOR EXE 2 DOOR 9 15 Diagram Part No. Description 10 No. 16 11 12 4 GL0251 Stove Glass Devon/Exe CE 6 Sided 5 YM-YM81001 Devon/Exe CE Twin Door Cross RH 6 YM-YM81101 Devon/Exe CE Twin Door Cross LH 11 YM-YA81057 Exe Air Slider Inner Plate Assembly 12 YM-C81087 Exe Air Slider Back Plate COMMON PARTS FOR EXE/DEVON/COUNTY FOR DEVON 2 DOOR 2 DOOR Diagram Part No. Description Diagram Part No. Description No. No. 5 YM-Y
Summary of the content on the page No. 18
18
Summary of the content on the page No. 19
19
Summary of the content on the page No. 20
A division of Stovax Ltd Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474500 Fax: (01392) 219932 E-mail: yeoman@stovax.com www.yeoman-stoves.co.uk