Sierra Products EF-4001B user manual

User manual for the device Sierra Products EF-4001B

Device: Sierra Products EF-4001B
Category: Stove
Manufacturer: Sierra Products
Size: 3.43 MB
Added : 3/3/2014
Number of pages: 13
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sierra Products EF-4001B. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sierra Products EF-4001B.

For your convenience

If looking through the Sierra Products EF-4001B user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sierra Products EF-4001B on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sierra Products EF-4001B to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sierra Products EF-4001B User manual - Online PDF
Advertisement
« Page 1 of 13 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sierra Products EF-4001B but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sierra Products EF-4001B. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

EF4001B AutoLite Pellet Stove Insert
Installation & Operating Instructions
Please read this entire manual before installation. Save these instructions.
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION
AND USE OF THIS PELLET FUEL-BURNING ROOM HEATER.
FAILURE TO FOLLOW T HE SE IN ST RU CT ION S C OU LD RE SU LT IN
PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
GENERAL INFORMATION
Installation and repair should be done by a qualified
service person. The heater should be inspected before use
and at

Summary of the content on the page No. 2

Provide adequate clearances around air openings into the Use only listed Type "L" pellet vent or stainless liner and com bustion chamber and adequate accessibility clearance for com ponents for installation. Failure to use listed com ponents se rvi cing and proper operation. Never obstruct the front will void your warranty. See pipe manufacturer instructions for opening of the heater. installation instructions. The heater may be installed as a free-standing unit m ount- OUTSIDE COMBUSTION AIR I

Summary of the content on the page No. 3

NOTE: THE INSERT W EIGHT IS SUBSTANTIAULLY FRONT HEAVY AND IF NOT FULLY SUPPORTED IT COULD FALL FORWARD. Figure 5 4. Ins tall vent system into existing chimney by using 3" flex from left side of hearth, passing damper and continuing to the top of the chimney. If the total vent length is longer than 10 Feet, install Ø4" vent from that point to top of chimney (Figure 6). Figure 3 3. If the hearth and fireplace floor are not at the same elevation, leveling legs may be installed on the rear of the u

Summary of the content on the page No. 4

Note - For best insert operation the flexible vent IMPORTANT - Any electrical work performed on the EASYFIRE Heater should be done by qualified personnel. installation should not have any tight bends. Try to achieve a smooth sweep to the vertical rise. Remote Control Thermostat Installation: SURROUND INSTALLATION The remote thermostat is designed to autom atically The surround supplied with the insert is adjustable in regulate the room temperature from the control panel heat height so as to a

Summary of the content on the page No. 5

1. A chimney connector shall no pass through and attic or UNIT ELECTRIC CONNECTIONS roof space, closet or similar concealed space, or a floor, or ceiling. Route the power supply cord from lower right side of unit to a grounded three prong 120VAC receptacle. Care should 2. W here a chimney passage through a wall, or partition of be taken to make sure the fireplace and hearth does not combustible construction is desired, the installation shall pinch or otherwise damage the cord. conform the CAN/CS

Summary of the content on the page No. 6

attempt to operate heater if glass becomes damaged in any GENERAL WARNINGS way! The EASYFIRE Pellet Stove and Insert has been designed and approved for burning wood pellet fuel only. Burning solid fuel in other forms is not permitted and will void all warranties. NEVER use gasoline, gasoline-type lantern fuels, kerosene, charcoal lighter fluid, or similar liquids to start or "freshen up" a fire. Keep all such liquids well away from the heater while it is in use. Ashes must be disposed of in a m

Summary of the content on the page No. 7

WARNING: Risk of electrical shock, disconnect all AC/DC C. In the MEDIUM position the EASYFIRE will be power before servicing. feeding approximately three (3) pounds of pellets per hour and the flame will fluctuate between 3" and 8" of ALWAYS TURN YOUR Heater OFF & LET IT COOL fire. BEFORE CLEANING. D. In the HIGH position the EASYFIRE will be feeding Your EASYFIRE Pellet Heater requires routine approximately 4+ lbs. per hour and the flame will maintenance for maximum performance and is mandato

Summary of the content on the page No. 8

run the fan in the CLEAN OUT position with the door open Solution: When the pellets are overfeeding, it usually for approximately one minute or until ash is no longer being means that the air flow has been reduced. Check the Fire picked up by the fan. Remember, you must always check Pot air intake holes to be sure they are clear. Check to the clean out cap on the tee after utilizing the CLEAN OUT see if Fire Pot was properly seated in pot tray. Check to feature. see if the manifold may have fi

Summary of the content on the page No. 9

HI TEMP/FLUE AND TRIM INDICATORS: W hen the Hi-Temp/Flue indicator light comes on (red lite beneath control button) it means that the flue is obstructed or you have a reverse draft and gases cannot exit properly. Maintenance is required and a thorough cleaning and pipe check must be performed. TRIM button : Underneath the control button you will find a small round button that will turn forward and reverse. This button can control the feed motor in the LOW position only. By turning the button c

Summary of the content on the page No. 10

Note: Caution must be taken when installing burn pot ALWAYS TURN YOUR Heater OFF & LET IT COOL or operating door not to damage ceramic glass. Do not BEFORE CLEANING. attempt to operate heater if glass becomes damaged in Your EASYFIRE Pellet Heater requires routine any way! maintenance for maximum performance and is mandatory for the warranty to remain in effect. 2. Control Functions: Control functions on the Easyfire The following procedures should be studied carefully and are as follows: OFF,

Summary of the content on the page No. 11

3. Cleaning the Exhaust Fan Blade & Heat Exchanger: The exhaust blower should be checked for excessive Fly- ash buildup. Regular and routine maintenance utilizing the CLEAN OUT feature will keep the exhaust blower housing and fan blades clean. This cleaning can only be done when the heater is NOT burning. For best results run the fan in the CLEAN OUT position with the door open for approximately one minute or until ash is no longer being picked up by the fan. Remember, you must always check t

Summary of the content on the page No. 12

deactivate the timer you will have to start over by turning the vent pipe is installed according to these instructions the knob to off and then back to FAN or LOW. smoke will syphon out of the pipe in most instances. 6. Problem: After several weeks of outstanding perfor- The EASYFIRE will automatically switch to 12 volt backup mance, the heater suddenly stopped and the red light provided you have the 12 volt option installed. under the control knob came on. This light is the Hi 2. Problem: The

Summary of the content on the page No. 13

ITEM No. PART NUMBER DESCRIPTION 1 110429 DOOR FRONT GLASS (Ceramic glass 11"x11 3/4"x5mm) 2 100119 GLASS FIBER GASKET 3 100125 DOOR FIBER ROPE GASKET 4 300536 FEED AUGER SYSTEM V3 5 300106 COMBUSTION BLOWER ASSEMBLY 6 120114 CONTROL BOARD V2.1 6A 110080 MAIN FUSE - 1 AMP 6B 110510 AUTOLITE FUSE - 5 AMP 7 200549 HEAT EXCHANGE COVER 8 110456 ASH DRAWER FIBER ROPE GASKET 9 110451 ASH DRAWER KNOB 10 120117 IGNITOR-200W 11 300512 BURN POT AL V2 12 120120 IGNITOR RELAY 13 120118 PUSH BUTTON SWITCH V2


Alternative user manuals
# User manual Category Download
1 Sierra Products EasyFire MODEL EF 3801 User manual Stove 8
2 Sierra Products EasyFire MODEL EF 5000 User manual Stove 17
3 Sierra Products Pellet Heater EasyFire B User manual Stove 2
4 Sierra Products EasyFire MODEL EFI 4000 User manual Stove 1
5 Sierra Products Wood User manual Stove 0
6 Sierra Products Pellet s User manual Stove 0
7 Sierra Products EasyFire MODEL EF 3800 User manual Stove 13
8 Sierra Products EASYFIRE EF5001U User manual Stove 0
9 Sierra Products Pellet Heater EF5001B-AL User manual Stove 0
10 Sierra Products Easyfire EF3801 User manual Stove 1
11 Edelbrock 2006-2007 (N) User manual Stove 4
12 Aarrow Fires SF 50 User manual Stove 1
13 Aarrow Fires EcoBurn BK043 User manual Stove 0
14 Aarrow Fires EcoBurn AFS1221 User manual Stove 0
15 Aga Ranges Berrington User manual Stove 3