Summary of the content on the page No. 1
www.regency-fi re.com
Owners &
ULTIMATE U38 Freestanding Gas Stove
Installation Manual
MODELS: U38-NG1 Natural Gas U38-LP1 Propane
FOR YOUR SAFETY
WARNING:
What to do if you smell gas:
If the information in these instructions are not followed ex-
Do not try to light any appliance
actly, a fi re or explosion may result causing property damage,
Do not touch any electrical switch:
personal injury or loss of life.
do not use any phone in your build-
FOR YOUR SAFETY
ing.
Do not store or use
Summary of the content on the page No. 2
To the New Owner: Congratulations! You are the owner of a state-of-the-art ULTIMATE Gas Stove by FIREPLACE ® PRODUCTS INTERNATIONAL LTD. The Regency Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the fl ick of a switch. The models U38-NG1, and U38-LP1 of this series has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort a
Summary of the content on the page No. 3
TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Operating Instructions ................................................19 Serial No. Decal ............................................................4 Lighting Instructions ....................................................19 Shutdown Instructions .................................................19 REQUIREMENTS First Fire ......................................................................19 Automatic Convection Fan Operation ........
Summary of the content on the page No. 4
Model/Modele: U38-NG1 Model/Modele: U38-LP1 SAFETY LABEL ® This is a copy of the label that accompanies NOTE: Regency units are constantly being each ULTIMATE Freestanding Gas Stove. We improved. Check the label on the unit and if have printed a copy of the contents here for your there is a difference, the label on the unit is the review. The safety label is located on the inside correct one. of the drop down pedestal door. Copy of the Safety Label for the U38-1 Freestanding Gas Stove Listed
Summary of the content on the page No. 5
REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished gr
Summary of the content on the page No. 6
INSTALLATION 12) Under no circumstances should this ap- IMPORTANT MESSAGE BEFORE YOU START pliance be modifi ed. Parts that have to be removed for servicing should be replaced SAVE THESE Safe installation and operation of this appli- prior to operating this appliance. ance requires common sense, however, we INSTRUCTIONS are required by the Canadian Safety Standards 13) Installation and any repairs to this appliance and ANSI Standards to make you aware of the The ULTIMATE Freestanding Gas
Summary of the content on the page No. 7
INSTALLATION 6) Test Gas Pressure. Refer to the "Gas Pipe OPTIONAL U38-NG1 & U38-LP1 Clearances Pressure Testing" section. OUTSIDE AIR 7) Install standard and optional features. A Side Wall to Unit 7-1/2" / 190 mm Refer to the following sections where Outside air for combustion can be brought in B Back Wall to Unit 6" / 155 mm applicable. either through the bottom of the pedestal or through the rear plate of the pedestal. E Side Wall to Unit 2" / 50 mm a. Log Set Installation b. Front
Summary of the content on the page No. 8
Summary of the content on the page No. 9
INSTALLATION 4) Light the pilot and turn the valve to "ON" GAS CONNECTION System Data position. U38-1 Converted to 30,000 Btu The gas line can be rigid pipe, or to make instal- lation easier, use a listed fl exible connector if For 0 to 4500 feet altitude 5) The pressure check should be carried out allowed by local codes. Copper may also be with the unit burning and the setting should Burner Inlet Orifi ce Sizes: used if approved by local codes. be within the limits specifi ed on the safety
Summary of the content on the page No. 10
INSTALLATION CONVERSION KIT# 731-969 FOR NG TO LP THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 3) Remove burner. See diagram below. 9) Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw Each Kit contains one LPG (Fig. 2), rotate it counter-clockwise until Conversion Kit and one DC it is free and extract it. Sparker Kit. LPG Conversion Kit Contains: Qty. Part # Description 1 904-529 5/32" Allen Key 1 904-641 Burner Ori
Summary of the content on the page No. 11
INSTALLATION 16) Unscrew the pilot orifi ce with the allen 23) Remove the front control panel by WARNING! key and replace with the LPG pilot unscrewing the 6 screws. orifi ce in the kit. Do not over tighten the screw. Recommended to grip the wrench by the short side. 13) Verify that if the conversion is from NG to LPG, the screw must be re- assembled with the red o-ring visible (Fig. 5). LPG Configuration Red o-ring visible 24) Unplug the Piezo Ignitor wire and remove Piezo Ignitor from the
Summary of the content on the page No. 12
INSTALLATION 28) Secure with screw. 37) Attach the green ground wire. 33) Attach the Piezo Ignition Wire to the back of the DC Sparker box. green ground wire 29) Reversing step 23 and secure the con- 38) Install the supplied battery into the DC Sparker trol panel back onto the stove pedestal Box by opening the battery compartment. with the screws. 34) The ground wire and DC Sparker ignition go through the hole on the heat NOTE: The battery in the DC Sparker Box will shield. need to be rep
Summary of the content on the page No. 13
INSTALLATION CONVERSION TO LOWER BTU RATING LOG SET INSTALLATION THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER Read the instructions below carefully and IF IN DOUBT DO NOT DO THIS CONVERSION !! refer to the diagrams. If logs are broken do not use the unit until they are replaced. Natural Gas Conversion Kit 730-920 Broken logs can interfere with the pilot Contains: operation. Qty. Part # Description 1 904-240 Burner Orifi ce #37 (NG) The gas log kit contains the following: 1 918-
Summary of the content on the page No. 14
G)02-48 INSTALLATION 3) Place Rear Log A)02-65 on the two pins on 11) Position notch in Front Right Log G)02-48 7) Place the Left Top Log D)02-46 on the pin the rear log support. on Log F)02-47 and push the bottom right on Log B)02-56 and on top of the cutout edge against the bracket on the burner on Log A)02-65. tray. G)02-48 A)02-65 A)02-65 A)02-65 D)02-46 B)02-56 E)02-45 C)02-44 Pins on Rear Log Support 4) Place the Middle Left Log B)02-56 on the Notch two pins as shown. Pin Cutout
Summary of the content on the page No. 15
INSTALLATION The smoke should be drawn into the draft FRONT DOOR LOUVER hood. If the smoke is not drawn into the draft INSTALLATION INSTALLATION hood, turn the unit off and check for the cause of lack of draft. (packaged separately) 1) Attach the top & bottom louvers to the side . stove panel using 2 screws per side. 1) Open the two side panels. 2) Slide the door onto the two hinge pins making sure the two pieces are fl ush together. See diagram 1. 3) Close the door. The latch plate
Summary of the content on the page No. 16
INSTALLATION OPTIONAL FINAL CHECK OPTIONAL REMOTE CONTROL WALL THERMOSTAT Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring ® Use the Regency Remote Control Kit ap- A wall thermostat may be installed if desired. correctly. This includes: proved for this unit. Use of other systems may Connect the wires as per the wiring diagrams. void your warranty. Note that the wires are connected to the "TH" 1) Clocking the appliance to ensure the cor-
Summary of the content on the page No. 17
Summary of the content on the page No. 18
Summary of the content on the page No. 19
OPERATING INSTRUCTIONS 2) Push in PILOT knob slightly and turn clock- ing off of any oils remaining from manufactur- OPERATING wise to off. Knob cannot be turned from ing. Smoke detectors in the house may go off INSTRUCTIONS pilot to off unless knob is pushed in slightly. at this time. Open a few windows to ventilate the room for a couple of hours. The glass may Do not force. Before operating this appliance, proceed through require cleaning. the following check list. 3) Wait fi ve minut
Summary of the content on the page No. 20