Regency Ultimate U39-NG1 user manual

User manual for the device Regency Ultimate U39-NG1

Device: Regency Ultimate U39-NG1
Category: Stove
Manufacturer: Regency
Size: 4.43 MB
Added : 5/11/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Regency Ultimate U39-NG1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Regency Ultimate U39-NG1.

For your convenience

If looking through the Regency Ultimate U39-NG1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Regency Ultimate U39-NG1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Regency Ultimate U39-NG1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Regency Ultimate U39-NG1 User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Regency Ultimate U39-NG1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Regency Ultimate U39-NG1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.regency-fi re.com
ULTIMATE U39
Owners &
Direct Vent Freestanding Gas Stove
Installation Manual
MODELS: U39-NG1 Natural Gas U39-LP1 Propane
WARNING: FOR YOUR SAFETY
If the information in these instructions are not followed exactly, What to do if you smell gas:
a fi re or explosion may result causing property damage, Do not try to light any appliance
personal injury or loss of life. Do not touch any electrical switch:
do not use any phone in your
FOR YOUR SAFETY
building.
Do not store or

Summary of the content on the page No. 2

® REGENCY ULTIMATE Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art ULTIMATE Direct Vent Gas Stove by FPI Fireplace ® Products International Ltd. The Regency Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the fl ick of a switch. The models U39-NG1, and U39-LP1 of this series has been approved by Warnock Hersey for both safety and effi ciency. As it also bears

Summary of the content on the page No. 3

TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Copy of Safety Label .....................................................4 Operating Instructions ................................................34 Shutdown Instructions .................................................34 First Fire ......................................................................34 REQUIREMENTS Lighting Procedure ......................................................34 Automatic Convection Fan Operation ............

Summary of the content on the page No. 4

SAFETY LABEL ® label is located on the inside of the drop NOTE: Regency units are constantly This is a copy of the label that accompanies being improved. Check the label on the down pedestal door. each ULTIMATE Direct Vent Freestanding unit and if there is a difference, the label Gas Stove. We have printed a copy of the on the unit is the correct one. contents here for your review. The safety Copy of Safety Label for U39 Gas Stove For the State of Massachusetts, installation and repair m

Summary of the content on the page No. 5

REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished gr

Summary of the content on the page No. 6

INSTALLATION This appliance installation must comply with IMPORTANT MESSAGE AWAY FROM FURNITURE AND the manufacturer's installation instructions and DRAPERIES. local codes, if any. In the absence of local codes SAVE THESE follow the current National Fuel Gas Code, ANSI INSTRUCTIONS Z223.1 and the current National Electrical Code WARNING: FAILURE TO INSTALL ANSI/NFPA 70 in the U.S.A., and the current THIS APPLIANCE CORRECTLY The ULTIMATE Direct Vent Freestanding Gas CAN/CGA B149 Gas Ins

Summary of the content on the page No. 7

INSTALLATION 4) This appliance is Listed for bedroom Before leaving this unit with the customer, 8) Any safety glass removed for servicing installations when used with a Listed Millivolt the installer must ensure that the appliance is must be replaced prior to operating the Thermostat. Some areas may have further appliance. fi ring correctly and operation fully explained requirements, check local codes before to customer. installation. 9) To prevent injury, do not allow anyone who is unf

Summary of the content on the page No. 8

INSTALLATION A) Cross Corner VENTING B) Room Divider C) Island INTRODUCTION D) Flat on Wall E) Flat on Wall Corner The DV Stove Horizontal Vent Kit and the F) Flush with Wall/ Alcove Simpson Dura-Vent Direct Vent System Model DV-GS venting systems, in combination with the ULTIMATE Direct Vent Freestanding Gas Stove, U39-NG1, and U39-LP1, have been tested and listed as direct vent heater systems by Warnock Hersey. If converting a Class-A Metal Chimney or Masonry Chimney to a Direct V

Summary of the content on the page No. 9

INSTALLATION EXTERIOR VENT TERMINAL LOCATIONS ® 9 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove A= Clearance above grade, veranda, porch, deck, or balcony *(min. with Dura-Vent termination cap (min. 12"/30cm) 12"/30cm) H= Not to be installed above a meter/regulator assembly within (3'/90cm) B= Clearance to window or door that may be opened *(12"/30cm) horizontally from the centerline of the regulator. C= Clearance to permanently closed window *(min. 12"/30cm) J= Clearance to service r

Summary of the content on the page No. 10

INSTALLATION 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Simpson American Metal ® Simpson Metal-Fab Security ® Selkirk ® Direct Vent GS Description Products ® ® Direct Vent Pro Sure Seal Secure Vent Direct-Temp™ Amerivent Direct Discontinued 6” Pipe Length, Galvanized 46DVA-06 908 4DT-6 N/A 4D6 SV4L6 6” Pipe Length, Black 46DVA-06B 908B 4DT-6B N/A 4D6B SV4LB6 7” Pipe Leng

Summary of the content on the page No. 11

INSTALLATION 4” x 6-5/8” Rigid Pipe Cross Reference Chart (Cont.) Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Simpson American Metal ® Simpson Metal-Fab Security ® Selkirk ® Direct Vent GS Description Products ® ® Direct Vent Pro Sure Seal Secure Vent Direct-Temp™ Amerivent Direct Discontinued 46DVA-IS - N/A from FPI N/A N/A 4DAIS12 N/A SV4RSA Attic Insulation Shield 12” Attic Insulation Shield - Cold Climates 36” N/

Summary of the content on the page No. 12

INSTALLATION RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations Alternate Horizontal Ter- mination Caps WARNING: Do not combine venting components from different venting systems. TM However use of the the AstroCap and FPI Riser is acceptable with all systems. This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with When using Rigid Vent other than Duravent Direct-Vent GS, Selkirk Direct-Temp, Simpson Dura-Vent, 3 screws must be Ameri Vent

Summary of the content on the page No. 13

INSTALLATION INSTALLATION RIGID PIPE VENTING ARRANGEMENTS PRECAUTIONS Horizontal Terminations for All Vertical Termination Systems for These venting systems are engineered Venting Systems Residential Manufactured and products that have been designed and Mobile Homes tested for use with the U39-NG1, and The shaded areas in the diagram below show U39-LP1. The warranty will be voided all allowable combinations of vertical runs The shaded area in the diagram below shows all with horizontal te

Summary of the content on the page No. 14

INSTALLATION o Horizontal Venting with Two (2) 90 Elbows o o One 90 elbow = Two 45 elbows. Option V H + H1 A) 3' Min. 2' Max. B) 5' Min. 3' Max. C) 8' Min. 4' Max. With these options, maximum total pipe length is 30 feet with minimum of 8 feet total vertical and maximum 4 feet total horizontal. Please note minimum 1 foot o between 90 elbows is required. Lengths do not include elbow indicated Vent restrictor position A (fully open), Refer

Summary of the content on the page No. 15

INSTALLATION DV STOVE HORIZONTAL VENT KIT (# 946-116 & #946-216) DV Stove Horizontal Vent Kit (2 ft. Part # 946-116 or 4 ft. Part # 946-216) includes all the parts needed to install the U39 with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents see the "Dura-vent Termiantion Kit and Component" sections. Qty. Description 1) 1 Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length, Kit # 946-216: 4 ft. (1.2m) length),

Summary of the content on the page No. 16

INSTALLATION Note: if the centerline cannot be met, the adjustable sections will have to be cut. e) Cut the 2 ft. or 4 ft. section of rigid pipe to length. Ensure that the pipe length when cut will seat onto both the starter o collar and the 90 elbow. Crimped section of rigid pipe seats into the o 90 elbow. Only cut the uncrimped side of pipe. Dismantle all pipe sections including vent terminal. 3) Attach the 4" dia. fl ex liner to the vent terminal ensuring that the fl ex overlaps

Summary of the content on the page No. 17

INSTALLATION DURA-VENT DURA-VENT VENTING TERMINATION KIT COMPONENTS You will require the following components with Minimum components for a Dura-Vent Planning Your Dura-Vent ® your new Regency Direct Vent Freestanding Horizontal Installation: Installation Gas Stove. Please review your product to make sure you have everything you need. In the A) Dura-Vent Horizontal Termination Kit There are two basic types of Dura-Vent Direct B) Wall Thimble (required for combus- event that you are missin

Summary of the content on the page No. 18

INSTALLATION Note: Note: DURA-VENT a) Twist-lock procedure: Four indentations, a) The horizontal run of vent should have located on the female ends of pipes and a 1/4 inch rise for every 1 foot of run HORIZONTAL fi ttings, are designed to slide straight towards the termination. Never allow the TERMINATIONS onto the male ends of adjacent pipes vent to run downward. This could cause and fi ttings, by orienting the four pipe high temperatures and may present the indentations so they mat

Summary of the content on the page No. 19

INSTALLATION Note: If installing termination on a siding Below Grade Installation DURA-VENT VERTICAL covered wall, a vinyl siding standoff If the Snorkel Termination must be installed or furring strips must be used to TERMINATIONS below grade, i.e. basement application, proper ensure that the termination is not drainage must be provided to prevent water from recessed into the siding. The four entering the Snorkel Termination. Refer to Dia. 1) Maintain the 1-1/4" wood screws p

Summary of the content on the page No. 20

INSTALLATION 4) Assemble the desired lengths of black pipe Offset Chart Roof Pitch Minimum Vent Height and elbows necessary to reach from the Feet Meters appliance adaptor up though the Round fl at to 7/12 2 0.61 Support Box. Insure that all pipes and elbow connections are in the fully twist-locked over 7/12 to 8/12 2 0.61 position and sealed. over 8/12 to 9/12 2 0.61 over 9/12 to 10/12 2.5 0.76 5) Cut a hole in the


Alternative user manuals
# User manual Category Download
1 Regency C33-NG2 User manual Stove 33
2 Regency C34-NG2 User manual Stove 6
3 Regency C33-LP2 User manual Stove 3
4 Regency F1100 User manual Stove 5
5 Regency F2400M User manual Stove 1
6 Regency C34-LP2 User manual Stove 2
7 Regency E33-NG User manual Stove 0
8 Regency E33-LP User manual Stove 1
9 Regency C33-NG3 User manual Stove 1
10 Regency F38-LPG2 User manual Stove 0
11 Regency F2402M User manual Stove 0
12 Regency C33-LP3 User manual Stove 2
13 Regency F37-NG User manual Stove 0
14 Regency F37-LPG User manual Stove 1
15 Regency F39-LPG User manual Stove 0
16 Edelbrock 2006-2007 (N) User manual Stove 4
17 Aarrow Fires SF 50 User manual Stove 1
18 Aarrow Fires EcoBurn BK043 User manual Stove 0
19 Aarrow Fires EcoBurn AFS1221 User manual Stove 0
20 Aga Ranges Berrington User manual Stove 3