Heat & Glo LifeStyle HEAT-N-GLO CFX-Grand-B user manual

User manual for the device Heat & Glo LifeStyle HEAT-N-GLO CFX-Grand-B

Device: Heat & Glo LifeStyle HEAT-N-GLO CFX-Grand-B
Category: Stove
Manufacturer: Heat & Glo LifeStyle
Size: 1.22 MB
Added : 1/13/2014
Number of pages: 23
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Heat & Glo LifeStyle HEAT-N-GLO CFX-Grand-B. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Heat & Glo LifeStyle HEAT-N-GLO CFX-Grand-B.

For your convenience

If looking through the Heat & Glo LifeStyle HEAT-N-GLO CFX-Grand-B user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Heat & Glo LifeStyle HEAT-N-GLO CFX-Grand-B on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Heat & Glo LifeStyle HEAT-N-GLO CFX-Grand-B to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Heat & Glo LifeStyle HEAT-N-GLO CFX-Grand-B User manual - Online PDF
Advertisement
« Page 1 of 23 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Heat & Glo LifeStyle HEAT-N-GLO CFX-Grand-B but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Heat & Glo LifeStyle HEAT-N-GLO CFX-Grand-B. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Models:
Installers Guide
FB-Grand
FB-IN
CFX-Grand-B
CFX-IN-B
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
WARNING: IF THE INFORMATION
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
WARNING: IMPROPER INSTALLA-
EXPLOSION MAY RESULT CAUS-
TION, ADJUSTMENT, ALTERATION,
ING PROPERTY DAMAGE, PER-
SERVICE OR MAINTENANCE CAN
SONAL INJURY, OR DEATH.
CAUSE INJURY OR PROPERT

Summary of the content on the page No. 2

SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully described in the Installing the Fireplace section of ! ! before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED. in a possible fire hazard and will void the warranty. This gas fireplace and vent assembly MUST be Prior to the first firing of the fireplace, READ the !

Summary of the content on the page No. 3

TABLE OF CONTENTS Safety and Warning Information ............................................... 2 u Service Parts Lists .................................................................... 4 Section 1: Approvals and Codes ............................................ 10 Appliance Certification ............................................................... 10 Installation Codes ...................................................................... 10 u High Altitude Installations ...............

Summary of the content on the page No. 4

FB-GRAND, CFX-GRAND-B Service Parts CFX-Grand-B: Manufacturing Dates: 9-01 to 12-02 (NG, LP) Exploded Parts Diagram FB-Grand-B: Manufacturing Dates: 8-02 to _____ (GN, PL) Vue éclatée des pièces u 13 FB-GRAND SHOWN 12 20 19 21 1 3 2 16 22 17 9 10 18 15 11 14 4 Log Set Assembly 8 5 6 Part number list on following page. Part number list on following page. * * 7 La liste des numéros de pièce se trouve La liste des numéros de pièce se trouve * * à la page suivante. à la page suivante. 4

Summary of the content on the page No. 5

(NG, LP) Service Parts List / Liste des pièces de rechange FB-GRAND IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de mo

Summary of the content on the page No. 6

(NG, LP) Service Parts List / Liste des pièces de rechange CFX-GRAND-B IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de

Summary of the content on the page No. 7

FB-IN, CFX-IN-B Service Parts (NG, LP) Exploded Parts Diagram CFX-IN-B: Manufacturing Dates: 12-02 to 9-01 (GN, PL) Vue éclatée des pièces FB-IN: Manufacturing Dates: 8-02 to ____ u 12 FB-IN SHOWN 20 19 21 22 2 3 1 16 17 9 18 10 15 11 4 Log Set Assembly 14 8 5 Part number list on following page. 7 * La liste des numéros de pièce se trouve * 6 à la page suivante. 7

Summary of the content on the page No. 8

FB-IN Service Parts List / Liste des pièces de rechange IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour

Summary of the content on the page No. 9

(NG, LP) Service Parts List / Liste des pièces de rechange CFX-IN-B IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de

Summary of the content on the page No. 10

Approvals and Codes Appliance Certification room in the U.S.A. and Canada. u High Altitude Installations The Heat-N-Glo appliance models discussed in this Installers Guide have been tested to certification standards U.L. Listed gas appliances are tested and approved with- and listed by the applicable laboratories. out requiring changes for elevations from 0 to 2,000 feet in the U. S. A. and in Canada. Certification When installing this appliance at an elevation above 2,000 feet, it may be necess

Summary of the content on the page No. 11

Getting Started Introducing the Heat-N-Glo Gas Appliances 3. To assure top performance, safety and efficiency, inserts must be installed with an approved flue liner as per CAN/ Heat-N-Glo direct vent gas appliances are designed to CGA B-149 or National Fuel Code ANSI Z223 and these operate with all combustion air siphoned from outside of instructions. the building and all exhaust gases expelled to the outside. WARNING: A HEARTH OR HEARTH EXTEN- The information contained in this Installers Guide,

Summary of the content on the page No. 12

INLET AIR STARTING COLLAR EXHAUST STARTING SURROUND COLLAR ON/OFF DOOR SWITCH GLASS ASSEMBLY LOWER GRILLE RATING PLATE GAS CONTROL VALVE LOW VOLTAGE WIRES ELECTRICAL JUNCTION BOX ACCESS GAS ACCESS B TOP VIEW C 2” (50.8mm) A MINIMUM FIREPLACE SIZE CFX-GRAND-B and FB-GRAND CFX-IN-B and FB-IN Location Inches Millimeters Inches Millimeters A Front Width 35 889 30-1/4 768.4 B Rear Width 22-5/8 574.7 19 482.6 C Depth 14-1/8 358.8 14-1/8 358.8 * Height 25-3/4 654 22-1/2 571.5 * NOTE: If exha

Summary of the content on the page No. 13

Dimensions in brackets are millimeters. A 5-9/16 [142] B 2-1/2 [64] REF 4 2-1/16 [102] [52] 13-3/4 [350] 3-1/8 [80] C ø 2-13/16 (2) D [71] F H E G 1-1/16 [28] GAS INLET ELECTRICAL 1-9/16 6-5/8 ACCESS 3-9/16 [40] [169] [91] (IF EQUIPPED) MODEL DIMENSIONS CFX-GRAND-B and FB-GRAND CFX-IN-B and FB-IN Location Inches Millimeters Inches Millimeters A 22-1/2 571 18 457 B 8-3/4 222 6-1/2 165 C 33-3/4 857.2 29-3/8 746.1 D 30-9/16 776 26-1/16 661 E 23-7/8 606 20-5/8 524 F 18-7/16 468 15-3/16 385 G 25-3/8

Summary of the content on the page No. 14

Installing the Insert of the last section of vent pipe. See dimension V in Figure 4. Step 1. Installing the Vent System A vertical vent termination system installed on this model will include one (1) length of 3-inch flexible vent pipe for the Vent System Installation Precautions combustion air, one (1) length of 3-inch flexible vent pipe for Before starting installation of vent kits, the installer should the exhaust air, one (1) pipe-to-cap adaptor, and one (1) read these instructions and the

Summary of the content on the page No. 15

Slide the gas insert into place, and HORIZONTAL OVERHANG position any excess flexible vent pipe back up into the chimney. Attach the pipe-to- cap adaptor to the termination cap and to the top of the flexible vent pipe and set VERTICAL WALL 2 FT. the cap in place at the top of the chimney. 2 FT. MIN. MIN. See Figures 4 and 5. LOWEST DISCHARGE CAUTION: TO AVOID DOWNDRAFTS OPENING AND/OR COLD AIR PROBLEMS, IT IS TERMINATION CAP RECOMMENDED TO SEAL OFF THE AREA BETWEEN THE TERMINATION CAP AND THE

Summary of the content on the page No. 16

This option shows both exhaust and inlet air vent pipes attached to the adaptor. TERMINATION CAP ADAPTOR EXHAUST COLLAR INLET AIR COLLAR EXHAUST VENT PIPE V= 14 FT. MINIMUM 40FT. MAXIMUM 3 INCH COLLAR (Factory installed to stainless steel section) WARNING: DO NOT BLOCK PIPE END WITH INSULATION OR ANY OTHER SEALING MATERIAL STAINLESS STEEL PIPE - 3 FT. MIN. REQUIRED (INCLUDED) INLET AIR VENT PIPE COLLAR ATTACHMENT BRACKET Figure 4. WARNING: THE EXHAUST VENT PIPE MUST THE INLET AIR PIPE

Summary of the content on the page No. 17

Note: Inspect for exhaust LOCKING collar gasket to insure TABS positive exhaust seal. LOCKING HANDLE TERMINATION CAP ADAPTOR EXHAUST VENT PIPE SUPPLIED WITH TERMINATION KIT INLET AIR VENT COLLAR (LINK-DV30 SHOWN) SLIDING PLATE INLET AIR VENT PIPE 3 INCH STAINLESS STEEL COLLAR ADAPTER FOR EXHAUST (MUST BE INSTALLED) Figure 5. Typical configuration of vent liners. 17

Summary of the content on the page No. 18

Step 2. Positioning, Leveling, and Step 4. The Gas Supply Line Securing the Insert NOTE: Have the gas supply line installed in accordance Remote Control with local building codes by a qualified installer The receiver for the remotes must be installed BETWEEN approved and/or licensed as required by the locality. the base pan of the insert and the firebox of the wood-burn- (In the state of Massachusetts installation must be ing fireplace (see photo below). performed by a licensed

Summary of the content on the page No. 19

Step 6. Wiring the Fireplace Step 5. Gas Pressure Requirements Pressure requirements for these gas appliances are shown NOTE: Electrical wiring must be installed by a li- in the table below. censed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- Pressure Natural Gas Propane SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- Minimum 5.0 inches 11.0 inches VENT ACCIDENTAL APPLIANCE OPERATION. Inlet Pressure w.c. w.c. For Standing Pilot Ignition Wiring Maximum Inlet 14.0 inches 14.0 inches A

Summary of the content on the page No. 20

INSERT STRAIN RELIEF WARNING: MUST USE THE CORD SUPPLIED AROUND CORD IN THIS END ! FROM OUTSIDE OF UNIT WITH THE J-BOX. FEED PLUG THROUGH HOLE SIDEWALL Fan Option (FB-IN & FB-Grand ONLY) On units already installed removal of decorative front, sur- round and gas insert is required. • Detach flexible liner from back of unit. • Remove the four screws on the coverplate (see Figure 11). JUNCTION BOX • Bend up the tabs on the base pan (see Figure 10). • Place the blower in between the bend up tabs. SC


Alternative user manuals
# User manual Category Download
1 Heat & Glo LifeStyle HEAT-N-GLO CFX-IN-B User manual Stove 5
2 Heat & Glo LifeStyle HEAT-N-GLO FB-IN User manual Stove 1
3 Heat & Glo LifeStyle WS-250 User manual Stove 2
4 Heat & Glo LifeStyle WS-150 User manual Stove 0
5 Heat & Glo LifeStyle MTL-INSERT User manual Stove 0
6 Heat & Glo LifeStyle HEAT-N-GLO FB-Grand User manual Stove 7
7 Edelbrock 2006-2007 (N) User manual Stove 4
8 Aarrow Fires SF 50 User manual Stove 1
9 Aarrow Fires EcoBurn BK043 User manual Stove 0
10 Aarrow Fires EcoBurn AFS1221 User manual Stove 0
11 Aga Ranges Berrington User manual Stove 3
12 Air King 4TM64A/9515A User manual Stove 3
13 Amana BIGOVEN ACF4215A User manual Stove 8
14 Amana Gas - Easy Touch Control Range User manual Stove 1
15 Amana BIGOVEN ACF4225A User manual Stove 4