Harman Stove Company HARMAN Super Magnum Coal Stoker user manual

User manual for the device Harman Stove Company HARMAN Super Magnum Coal Stoker

Device: Harman Stove Company HARMAN Super Magnum Coal Stoker
Category: Stove
Manufacturer: Harman Stove Company
Size: 5.48 MB
Added : 1/5/2014
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Harman Stove Company HARMAN Super Magnum Coal Stoker. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Harman Stove Company HARMAN Super Magnum Coal Stoker.

For your convenience

If looking through the Harman Stove Company HARMAN Super Magnum Coal Stoker user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Harman Stove Company HARMAN Super Magnum Coal Stoker on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Harman Stove Company HARMAN Super Magnum Coal Stoker to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Harman Stove Company HARMAN Super Magnum Coal Stoker User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Harman Stove Company HARMAN Super Magnum Coal Stoker but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Harman Stove Company HARMAN Super Magnum Coal Stoker. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Do Not
Discard
Owner's Manual
Installation and Operation
Model:
Super-Magnum
Coal Stoker Stove
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating and
• Read, understand and • Leave this manual with
maintenance instructions
follow these instructions party responsible for use
included.
for safe installation and and operation.
operation.
WARNING WARNING
Please read this entire manual
HOT SURFACES!
before installation and use of this
Glass and oth

Summary of the content on the page No. 2

Super-Magnum Coal Stoker Stove Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you have become part of a long standing family committed to meeting the heating needs of consumers with the most distinctive, powerful and responsible home heating products available. The Super-Magnum has huge features in an elegant package, giving you 5000 to 100,000+ BTU when you need it, automatically. You need only set your desired room temperature, keep

Summary of the content on the page No. 3

Super-Magnum Coal Stoker Stove TABLE OF CONTENTS Section 1: Listing and Code Approvals Section 9: Troubleshooting A. Appliance Certifications 4 Troubleshooting Chart 23 B. Mobile Home Approval 4 C. Glass Specifications 4 Section 10: Service & Maintenance D. Electrical Rating 4 A. Shut-Down Procedure 24 E. BTU & Efficiency Specifications 4 B. Quick Reference Maintenance 24 C. General Maintenance Procedures 25 Section 2: Special Warnings and Notes D. Motors and Components

Summary of the content on the page No. 4

Super-Magnum Coal Stoker Stove Listing and Code Approvals 1 A. Appliance Certification E. BTU & Efficiency Specifications Model: Super Magnum Coal Stoker Particulate Emissions Laboratory: OMNI-Test Laboratories, Inc. Not Tested Rating: Report No. 135-S-24-6.2 Type: Solid Fuel Room Heater / Coal 5,000 - 103,000 / hr *BTU Input: Burning Type. Heating Capacity: 2,500 sq. ft. or more Standard(s): UL1482, UL391, & ULC S627-00 Hopper Capacity: 110 lbs. This appliance is also approved for ins

Summary of the content on the page No. 5

Super-Magnum Coal Stoker Stove Special Warnings and Notes 2 Carbon monoxide, referred to as CO, is a colorless, odorless CO detectors are very sensitive and may sound an alarm gas that is produced during combustion of coal and other for fumes other than CO or CO from sources other than fuels. CO fumes are toxic and can be fatal. the stove such as car or lawn mower exhaust. The Super-Magnum is a natural draft system which relies If the alarm sounds on a properly designed chimney to remove

Summary of the content on the page No. 6

Super-Magnum Coal Stoker Stove Getting Started 3 A. Design, Installation & Location B. Fire Safety Considerations Maintain the designated clearances to combustibles. Insulation must not touch the chimney. You must 1. Appliance Location maintain the designated air space around the chimney. Consideration must be given to safety, convenience, This space around a chimney is necessary to allow traffic flow, and the fact that the appliance will need a natural heat removal from the area. Insula

Summary of the content on the page No. 7

Super-Magnum Coal Stoker Stove C. Component Locations Coal Storage Hopper Removable Hopper Lid Heat Transfer Kit Filler Plate Air Grill Load Door Ash Removal Door Exhaust Sensing Probe (ESP) Heat Exchange Cleaning Rod TM Verti-Flow Feeder Control Panel Distribution Air Filter Distribution Blower 3-90-02702R4_08/12 Do Not Burn Wet Coal! 7

Summary of the content on the page No. 8

Super-Magnum Coal Stoker Stove D. Pre- Use Check List 1. Place the appliance in a location near the WARNING final installation and follow the procedures Inspect appliance and components for below: damage. Damaged parts may impair safe 2. Open the appliance and remove all articles operation. • Do NOT install damaged components. packed inside. Inspect all items for shipping • Do NOT install incomplete components. damage. Notify dealer of any missing or • Do NOT install substitute components

Summary of the content on the page No. 9

Super-Magnum Coal Stoker Stove Dimensions & Clearances 4 A. Appliance Dimensions 3-90-02702R4_08/12 Do Not Burn Wet Coal! 9

Summary of the content on the page No. 10

Super-Magnum Coal Stoker Stove B. Clearances To Combustibles E A C D F B E Parallel Corner Inches Millimeters Inches Millimeters Installation Installation Back Wall To Unit Hopper 2 51 Walls to Unit Body 15 381 A E Side Wall To Unit 24 610 Walls to Flue Connector 24 610 B F Back Wall To Flue Connector 17 432 C 34 864 Side Wall To Flue Connector D C. Floor Protection Requirements Floor protection must be of a non-

Summary of the content on the page No. 11

Super-Magnum Coal Stoker Stove Chimneys and Venting 5 No part of the chimney connector may pass through A. Draft an attic or roof space, closet or other concealed space, Draft is widely misunderstood. It is important that you, or through a floor or ceiling. Whenever possible, avoid the stove operator, realize that draft is a variable effect, passing the connector through a combustible wall; if you not a given quantity. Stoves and chimneys do not have must, use an approved wall pass-thr

Summary of the content on the page No. 12

Super-Magnum Coal Stoker Stove Closest Non-combustible cover, one Combustible Minimum 2" (50mm) side only. If two covers are Material Clearance to Brick used, each must be mounted Hole with a minimum on non-combustible spacers clearance of 18" (450 mm) Minimum 12" at least 7/8" (21mm) away between connector and wall. Liner (300mm) to Brick from the wall. Fire Clay Thimble Chimney Connector Masonry Chimney Built to 1" (25mm) NFPA 211 Specifications. Clearance Minimum 12" (300mm)

Summary of the content on the page No. 13

Super-Magnum Coal Stoker Stove 1. Existing Masonry Chimneys If you plan on using a pre-existing masonry chimney, have it thoroughly inspected and cleaned. Any faults which make the chimney unsafe and unusable must be repaired prior to use. These can include improper height, structural defects, blockages, inadequate clearance to combustibles, unsealed openings into other rooms of the house, signs of creosote or smoke leakage, a loose or absent clean-out door, or absence of a liner. 2. Vent

Summary of the content on the page No. 14

Super-Magnum Coal Stoker Stove E. Draft Test Procedure Because of the dangers associated with coal gases and the potential for carbon monoxide release, It is important to balance the airflow into the stove with the draft in the flue. The combustion blower has a restrictor plate attached to it, which must be adjusted upon completion of the installation. The barometric damper, if installed, must also be set to prevent over-drafting in the appliance. Follow these steps to ensure safe and e

Summary of the content on the page No. 15

Super-Magnum Coal Stoker Stove Mobile Home 6 A. Mobile Home Installation CAUTION Mobile home approval - U.S. only. Maintain structural integrity of mobile home: 1. An outside air inlet must be provided for • Floor, wall, ceiling and/or roof. combustion air, and must remain clear of leaves, Do NOT cut through: debris, ice, and/or snow. The outside air path must • Floor joist, wall studs, or ceiling trusses. be unrestricted while the appliance is in operation. • Any supporting material that w

Summary of the content on the page No. 16

Super-Magnum Coal Stoker Stove Appliance Set-Up 7 A. Outside Air Attachment Parts and Supplies Needed: 1 piece of metal flexible pipe, 3" X needed length. 1 Rodent Screen, Plus, you'll want to obtain a trim ring for finishing around the pipe on the inside wall. 1. Remove the knockout from the bottom shield. There are three small areas that are not previously cut. You can cut these tabs using a hacksaw or by drilling them. A small rounded file will be helpful in removing any sharp burrs

Summary of the content on the page No. 17

Super-Magnum Coal Stoker Stove B. Leveling the Appliance D. Air Filter To adjust the leveling bolts, you must first loosen To ensure cleanliness of the air circulated through the the locking nut. Turn the leveling bolt to the desired heat exchange, the Super Magnum is equipped with a position, and re tighten the locking nut against the cast replaceable filter. The filter is located under the stove. iron leg. To remove the filter, loosen the two thumb screws and remove the cover. Slide the

Summary of the content on the page No. 18

Super-Magnum Coal Stoker Stove To Install the air grill, remove the existing painted F. Optional Door Trim Kit grill. Then, using the same two screws and spring The door trim kit includes a brushed stainless frame for washers, install the brushed stainless grill. each door, and an air grill. To install the optional door trim, you'll first need to remove the latch mechanism from the door. The process is the same for each door. 1. Using a hex key wrench, loosen the set screw at the latch.

Summary of the content on the page No. 19

Super-Magnum Coal Stoker Stove Operating Instructions 8 A. Fuel Specifications B. General Operating Information The Super Magnum is designed for use with The Super Magnum's ESP control will maintain an Anthracite "Rice" coal Only. Anthracite is a hard coal output level to fit your temperature demands. There are which is mined mostly in the Eastern United States. two modes of operation; "Stove Temp" mode, where the The post-mining process involves breaking the large control will maintain a

Summary of the content on the page No. 20

Super-Magnum Coal Stoker Stove 2. Circuit Board As stated previously, the circuit board is a microprocessor, which means it has the ability to "think" and adjust itself based on both reported temperatures and demand temperature. The circuit board also has the ability to self-diagnose when things are not happening as they should be. Power Light Indicates power to the Feed adjuster control. Sets the maximum feed rate Status Light Will be lit in either stove Test or room temp mode when Runs


Alternative user manuals
# User manual Category Download
1 Harman Stove Company 929 DV User manual Stove 1
2 Harman Stove Company Conquest Gas User manual Stove 0
3 Harman Stove Company DVC-500 User manual Stove 7
4 Harman Stove Company Accentra 2 User manual Stove 10
5 Harman Stove Company Harman Pellet P43 User manual Stove 4
6 Harman Stove Company Harman Gas 929BV User manual Stove 2
7 Harman Stove Company FireLuxe Direct Vent GasWith Top Cooking Burner System User manual Stove 0
8 Harman Stove Company HARMAN P68 User manual Stove 0
9 Harman Stove Company HarmanThe Harman Magnum Stoker User manual Stove 3
10 Harman Stove Company I User manual Stove 0
11 Harman Stove Company Hot Air s SF1500A User manual Stove 0
12 Harman Stove Company Advance Pellet User manual Stove 1
13 Harman Stove Company HARMAN TL200 User manual Stove 4
14 Harman Stove Company III User manual Stove 0
15 Harman Stove Company MARK I User manual Stove 0
16 Edelbrock 2006-2007 (N) User manual Stove 4
17 Aarrow Fires SF 50 User manual Stove 1
18 Aarrow Fires EcoBurn BK043 User manual Stove 0
19 Aarrow Fires EcoBurn AFS1221 User manual Stove 0
20 Aga Ranges Berrington User manual Stove 3