Summary of the content on the page No. 1
PELLET STOVE
EF- ΙΙ i
OWNER’S TECHNICAL MANUAL
SHERWOOD INDUSTRIES LTD.
6782 OLDFIELD ROAD
VICTORIA, BRITISH COLUMBIA
V8M-2A3
Summary of the content on the page No. 2
ENVIROFIRE INSTALLATION MANUAL TABLE OF CONTENTS INTRODUCTION Important Safety Data......................................................................3 Pellet Quality ...................................................................................4 Warnings and Recommendations....................................................5 Automatic Safety Features ..............................................................5 OPERATION How to Start Your Pellet Stove ..................
Summary of the content on the page No. 3
IMPORTANT SAFETY DATA Please read this entire manual before installation and use of this pellet fuel burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death. CAUTION: DO NOT CONNECT OT ANY AIR DISTRIBUTION DUCT OR SYSTEM; DO NOT BURN GARBAGE OR FLAMABLE FLUIDS SUCH AS GASOLINE, NAPTHA OR ENGINE OIL; HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. Contact local build
Summary of the content on the page No. 4
PELLET QUALITY IS IMPORTANT, PLEASE READ THE FOLLOWING PAGE Your pellet stove has been designed to burn wood pellets only. Since there are many manufacturers of wood pellets it is important to select pellets that are free of dirt or any impurities. The Pellet Fuel Industries (P.F.I.) has established standards for wood pellet manufactures. We recommend the use of pellets that meet or exceed these standards. Ask your dealer for a recommended pellet type. THE PERFORMANCE OF YOUR PELL
Summary of the content on the page No. 5
WARNINGS AND RECOMMENDATIONS A. Do not abuse the glass by striking or slamming the door shut. B. Do not attempt to operate the stove with broken glass. C. Do not attempt to open the door and clean the glass while the unit is in operation. If you must clean the glass, use a soft cotton cloth and mild window cleaner. D. Do not use abrasive cleaners to clean the surface or any part of the stove. E. It is recommended that the unit be secured into its position in order to avoid any d
Summary of the content on the page No. 6
HOW TO START YOUR PELLET APPLIANCE 1. Fill hopper with pellets. 2. Switch the power on by pushing the rocker switch to the manual position. FAN CONTROLLER 3. Turn Dial A Fire knob to the 12 o’clock position. (The lower grade pellets may need a higher setting on the feed rate.) 4. Approximately 15 minutes after the fire was lit, the green light should come on. WHEN THE GREEN LIGHT COMES ON, PUSH THE ROCKER SWITCH TO GREEN LIGHT THE AUTO POSITION. Now the stove will shut o
Summary of the content on the page No. 7
SLIDER/DAMPER INSTALLATION /OPERATIONS INSTRUCTIONS This is used to regulate the airflow through the pellet stove. INSTALLATION: 1. Remove the slider rod (short rod with knob and nuts) and the two nuts from their package and open the left side panel. This is the smaller of the two rods. Remove the knob from the knob. 2. Remove the knob and the outer nut from the rod. Push the rod through the hole in the slider. Place the other nut on the rod and tighten, leaving a 1/32” gap betwe
Summary of the content on the page No. 8
AREAS FOR ROUTINE INSPECTION The following should be inspected periodically to ensure that the appliance is operating at its optimum and giving you excellent heat value: 2-3 DAYS/WEEKLY SEASONALLY or 2 TONS OF FUEL Burn Pot and Liner Exhaust Vent and Fresh Air Intake Tube Ash Pan Blower Mechanisms Inside Firebox Heat exchanger tubes Behind Firebox Liners Latch Mechanism of ash pan Door Glass Door Latch Heat exchanger tubes All Hinges Ash pan and Door gaskets Post Season Clean-up
Summary of the content on the page No. 9
DOOR GLASS (It is recommended that your dealer replace the glass if broken.) The door glass is made of 5 mm thick, high temperature PYROCERAMIC The center panel is 229 mm x 330 mm. To replace the glass, unscrew and remove the four glass retainers. Remove the glass and any broken pieces. High temperature fiberglass tape should be used around the glass. Replace the glass, center the glass assembly in the frame, then screw the glass retainers back to the frame. The use of substitute mate
Summary of the content on the page No. 10
ELECTRICAL COMPONENT FUNCTIONS The following is a list of electrical components and their functions on the ENVIROFIRE EF-IIi pellet stove. 1. CONVECTION FAN CONTROLLER This controller is responsible for varying the speed of the convection blower. The stove has a fan control-over- ride. Should the convection blower be set on low and the Dial-A-Fire set on high, the convection blower will by- pass the fan controller and go to high. This will cool the stove until control is given back to t
Summary of the content on the page No. 11
10. 160 °F (71 °C) TEMPERATURE SENSOR When this sensor (located on the left side firewall) reaches 160 °F (71 °C), the convection blower will go to high, cooling the unit. 11. 120 °F (49 °C)- N/O TEMPERATURE SENSOR (SHUT DOWN SENSOR) This sensor (mounted on the exhaust blower housing) has two functions (only if the auto/manual switch is in the auto position): -Should the fire happen to go out, this sensor will shut the stove off when the exhaust temperature drops below 120 °F (49 °
Summary of the content on the page No. 12
DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE 1. Check clearances to combustibles. 2. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be obtained from a ventilated crawlspace. 3. Do not install the stove in a bedroom. 4. You can vent the stove through an exterior wall behind the unit or connect it to an existing masonry or metal chimney (must be lined if the chimney is over 6” in diameter, or less than 28 sq. inches cross sectional are
Summary of the content on the page No. 13
REMOVING YOUR NEW STOVE FROM IT’S PALLET To remove your new stove from its pallet, open the left and right side panels. There are two wood screws that are holding the bottom of the stove to the pallet. Remove the screws. Close the side panels. See PAGE 18 how to install the pedestal. INSERT MODEL FREESTAND MODEL REMOVE SCREW HERE DIMENSIONS 22” SURROUND PANEL 11 ½” 24” 30.5” 13
Summary of the content on the page No. 14
MASONRY FIREPLACE INSERT INSTALLATION, MODEL FPI The Fireplace insert model includes a surround faceplate and a pedestal. When installing this unit, ensure that the pedestal is removed from the inside of the hopper and installed on the bottom of the unit. (Surround assembly instructions are in this manual) CLEARANCES TO COMBUSTIBLES Side wall 8” (200 mm) from the body of the heater Facing on masonry fireplace 8” (200 mm) from the body of the heater Mantle 8” (200 mm) from the bo
Summary of the content on the page No. 15
ASSEMBLING THE FACE PLATE FOR THE FPI AND BIH MODELS 1. Assemble the brass frame using the corner hardware and screws supplied in the face place packaging. Install corner hardware into the side brass, then push into the top frame. Do not over- tighten or the side bass cannot be removed during servicing. 2. Assemble the three faceplates to the stove by screwing in the hinged panels to the stove side panels. Loosen the front hopper lid screws and center the top panel under the hopper li
Summary of the content on the page No. 16
RECOMMENDED FRAMING FOR BUILT IN HEATER When installing model BIH it is recommended that you use the dimensions shown in the diagram below. These clearances will make it easy and readily accessible for service. BUILT IN HEATER CLEARANCES TO COMBUSTIBLES This unit includes a 3” (75 mm) pedestal and surrounding faceplates. The part of the unit behind the faceplate can be enclosed with combustible material. Model BIH has 1” (25 mm) standoffs to establish clearances to combustibles to
Summary of the content on the page No. 17
CLEARANCES TO COMBUSTIBLES CLEARANCE TO COMBUSTIBLES (FREESTANDING) - Side wall to unit A- 6 INCHES (150 mm) - Back wall to unit B- 1 INCH (25 mm) - Corner to unit C- 1 INCH (25 mm) - Mantle (Hearth Mount) 8 INCHES ( - Combustible flooring underneath the unit and extending 6 INCHES (150 mm) to the sides and front must be protected by a non combustible material. ALCOVE DIMENSIONS Minimum Alcove width........... 36 inches (900 mm) Minimum Alcove height ......... 48 i
Summary of the content on the page No. 18
MODEL FS (FREESTANDING) INSTALLATION PEDESTAL INSTALLATION Model FS comes with a pedestal that has to be attached prior to installation: - Remove the pedestal from the box - Remove the ENVIROFIRE unit from the box - Place the unit on its back, making sure not to damage the wiring. - Back off the screws on the base, install the pedestal over the screws. - Lock pedestal in place using the keyholes, tighten the screws. Return unit to upright. INSTALLATION KEYHOLES 18
Summary of the content on the page No. 19
HORIZONTAL EXHAUST THROUGH THE WALL 1. NOTE: Use only listed type “PL” or “L” pellet venting products. Failure to use listed components may cause damage or personal injury or death. 2. Choose a location for your stove that meets the requirements stated in this manual and allows installation with the least amount of interference to house framing, plumbing, wiring, etc. 3. Install a non-combustible hearth pad underneath the unit extending 6 inches (15 cm) in front of and to the sides (w
Summary of the content on the page No. 20
THROUGH WALL INSTALLATION 1” 20