SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
PELLET STOVE
Mini
TECHNICAL MANUAL
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE
OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY
OR EVEN DEATH
Contact your building or fire officials about restrictions and installation
inspection requirements in your are
Summary of the content on the page No. 2
Table of Contents Introduction...................................................................................................................................3 Rating Label Location................................................................................................................3 Safety Warnings And Recommendations.....................................................................................3 Installation....................................................................
Summary of the content on the page No. 3
Introduction * This manual is designed for the technician in conjunction with the owner’s manual. * RATING LABEL LOCATION: The rating label is located on the back of the unit. SAFETY WARNINGS AND RECOMMENDATIONS: Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death. Any unauthorized modification of the appliance or use of replacement parts not recommended
Summary of the content on the page No. 4
Introduction SOOT: Operation of the stove with insufficient combustion air will result in the formation of soot which will collect on the glass, the heat exchanger, the exhaust vent system, and may stain the outside of the house. This is a dangerous situation and is inefficient. Frequently check your stove and adjust the slider/ damper as needed to ensure proper combustion. See: “SLIDER/DAMPER SETTING”. CLEANING: There will be some build up of fly ash and small amounts of creosote in the exhau
Summary of the content on the page No. 5
Introduction INSTALLATION: Contact your local building or fire official to obtain a permit and any information on installation restrictions and inspection requirements for your area. All local regulations, including those referring to national and European Standards need to be complied with when installing this appliance. Be sure to maintain the structural integrity of your home when passing a vent through walls, ceilings, or roofs. It is recommended that the unit be secured into its positio
Summary of the content on the page No. 6
Installation DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE: 1. Check clearances to combustibles. 2. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be obtained from a ventilated crawlspace. 3. Do not install the stove in a bedroom. 4. You can vent the stove through an exterior wall behind the unit or connect it to an existing masonry or metal chimney (must be lined if the chimney is over 6” (15 cm) diameter, or over 28 inches² (180 cm²) c
Summary of the content on the page No. 7
Installation APPLIANCE DIMENSIONS AND SPECIFICATIONS: 1 1 5 / 2 " ( 3 9 3 m m ) Weight (with full hopper): 238 lb (108 Kg) Hopper Capacity: up to 48 lb (21.8 Kg) Voltage: 110 - 120 V Max Current: 4.1 Amps Consumption on High: 3.1 lb/hr (1.4 Kg/hr)* Consumption on Low: 1.3 lb/hr (0.6 Kg/hr)* (Note: Consumption will vary with the type of fuel used.) 7 7 17 / 8 " 18 / 8 " ( 4 5 5 m m ) (4 81 m m ) 3 4" ( 864 m m ) 1 5 19 / 8 " 1 7 / 2 " ( 4 97 m m ) ( 4 4 4 m m ) 1 1 18 / 2 " 2 2 / 8 " ( 4 70 m m
Summary of the content on the page No. 8
A d j a c e n t W a l l Installation CLEARANCES TO COMBUSTIBLES: IMPORTANT: Attach the Mini’s Hearth Pad when installing the unit on a combustible floor. The supplied hearth pad meet all the requirement of a proper hearth pad. If you do not use the supplied hearth pad a hearth pad must be used when on combustible material. If the Mini is installed on carpet the use of a solid 3" B a c k W a l l ( 7. 5c m ) material must be used under leveling legs. 4" ( 10cm ) 8 " These dimensions are minimum
Summary of the content on the page No. 9
Installation VENT TERMINATION REQUIREMENTS: IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER. Table 2: Use in conjunction with Figure 5 for allowable exterior vent termination locations. Letter Minimum Clearance Description A 24 in (61 cm) Above grass, top of plants, wood, or any other combustible materials. B 48 in (122 cm) From beside/below any door or window that may be opened. C 24 in (61 cm) From above any door or window that may be opened. D 24 in
Summary of the content on the page No. 10
Installation OUTSIDE FRESH-AIR CONNECTION: Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes. � � � � � � � A Fresh-air intake is strongly recommended for � � � � all installations. Failure to install intake air may result in improper combustion as well as the unit smoking during power failures. When connecting to an outside fresh air source, do not use plastic or combustible pipe. A 2” minimum (51 � � � � � � � � � � � � � � � � � � � � � � �
Summary of the content on the page No. 11
Installation MOBILE HOME INSTALLATION: ● Secure the heater to the floor using the two holes in the pedestal. ● Ensure the unit is electrically grounded to the chassis of your home (permanently). ● Do not install in a room people sleep in. ● Outside fresh air is mandatory. Secure outside air connections directly to fresh air intake pipe and secure with three (3) screws evenly spaced. CAUTION: THE STRUCTURAL INTEGRITY OF THE E N V IR O M i ni MANUFACTURED HOME FLOOR, O p t i o n a l WAL
Summary of the content on the page No. 12
Installation HORIZONTAL EXHAUST THROUGH WALL INSTALLATION: Vent installation: install vent at clearances specified by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor, or ceiling. Where passage through a wall or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365 Installation Code for Solid-Fuel-Burning Appliances and Equipment. Only use venting of L or PL type
Summary of the content on the page No. 13
Installation 9. The pipe must extend at least 12” (30 cm) away from the building. If necessary, bring another length of pipe (PL type) to the outside of the home to connect to the first section. Do not forget to place high temperature silicone around the pipe that passes through the thimble. 10. Install a vertical pipe, or if all requirements for direct venting are met, install vent termination. The stainless steel cap termination manufactured by the vent manufacturer is recommended. However,
Summary of the content on the page No. 14
Installation INSIDE VERTICAL INSTALLATIONS: 1. Choose a stove location that is ideal. See the � � � � � � � � � � � � � � � � � � � section “DECIDING WHERE TO LOCATE YOUR PELLET � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � APPLIANCE.” � � � � � � � 2. Place a non-combustible hearth pad where � � � � � � � � � � � � necessary. � � � � � � � � � � � � � � � � � � � � � � 3. Place the unit on the hearth pad (if installed � � � � � � � � � � � � � on a co
Summary of the content on the page No. 15
� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � Installation HEARTH MOUNT INSTALLATION: � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � F l u e � � � � � � � � � � � � � � � Refer to Figures 17 and 18. C o nn e c to r � � � � � � � � � � � � � � 1. Install the hearth pad. 2. Lock fireplace damper in the open position. 3. Install a positive flue connector at the fireplace dampers
Summary of the content on the page No. 16
Installation EXTERIOR MOUNTED EXHAUST BLOWER (20-070): The Mini can be equipped with an externally mounted exhaust blower. This optional kit includes all components necessary to install the exhaust blower on any vertical wall surface. Choose a location for your stove that meets the requirements stated in your manual and allows installation with the least amount of interference with house framing, plumbing, wiring, etc. Included in the Exterior Mounted Exhaust Blower Kit are: 1 - Exhaust blo
Summary of the content on the page No. 17
Installation TYPICAL THROUGH WALL WITH EXTERIOR BLOWER KIT INSTALLATION - HORIZONTAL TERMINATION: 90 ° E l bow 45° E l b ow w i t h R o de nt scr e e n o r s ta i nl e s s st e e l t er m i na t i o n h o od 2 f t ( 6 10m m ) R i s e r P i p e A dap to r E xte r i or B l o w e r a nd H o usi n g E l e c tr i c al C ab l e Figure 22: Through Wall Installation with Exterior Blower Kit. NOTE: Ensure that all interior vent connections are sealed by placing a small bead of high temperature silicone
Summary of the content on the page No. 18
Installation TYPICAL THROUGH WALL WITH EXTERIOR BLOWER KIT INSTALLATION - VERTICAL TERMINATION: Follow the previous pages for through wall installations. Ensure that vent pipe is properly secured to wall using wall straps. Maintain clearances to combustibles on vent pipe as well as unit. R oof S h e athi n g R a i n C a p R oof F l as h i ng R oo f R a f t er s C ei l i ng J oi st s V e n t P i pe E x ter i o r W a l l S h ea t h i n g Outsi de V en t T e r m i n a ti on Figure 24: Through Wall
Summary of the content on the page No. 19
Installation THERMOSTAT INSTALLATION: 1. Install the wall thermostat in a location that is not to close too the unit but will effectively heat the desired area. 2. Install a 12 or 24 Volt Thermostat using an 18 x 2 gauge wire from the unit to the thermostat. If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or idle setting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go to the setting that is displayed on the
Summary of the content on the page No. 20
Installation SLIDER/DAMPER SET-UP: This is used to regulate the airflow through the pellet stove. The slider damper should be set by a trained technician using magnehelic. The slider damper is located behind the left side panel. To open the left side panel, undo the one screw located in the upper front corner of the cabinet side between the louvers. Also loosen three screws down the back of the side panel. A i r I nt ake B o x The combustion exhaust blower is a variable speed blower contro