Summary of the content on the page No. 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Sonnet
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
flame.
• Do not try to light any appliance.
• Do not touch any electrical switch
or use any phone in your
Summary of the content on the page No. 2
Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, if the pilot or pilot and in accordance with their instructions. Carefully read all burners have gone out on their own, open the the instructions in this manual first. Consult the building glass door and wait 5 minutes to air out before authority having jurisdiction to determine the need for a
Summary of the content on the page No. 3
Table of Contents Safety Precautions........................................................................................................2 Table of Contents..........................................................................................................3 Codes And Approvals....................................................................................................4 Specifications..................................................................................................
Summary of the content on the page No. 4
Codes And Approvals DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. BV: This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L vent. May also be vented through a conventional chimney using a chimn
Summary of the content on the page No. 5
Specifications RATING LABEL LOCATION: The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the fireplace. DIMENSIONS: 1 5 1 3 / 1 6 " ( 3 5 5 m m ) 3 1 5 1 3 / 16 " 1 0 / 1 6 " ( 3 3 6 m m ) S on ne t T o p w i t ho ut ( 27 8 m m ) a T r i m Ins t a l l e d 1 24 / 1 6 " ( 6 12 m m ) 3 1 7 / 4 " ( 4 51m m ) 7 8 / 8 " ( 225m m ) 1 2 / 4 " ( 57m m ) S o n n e t T op w i t h 5 12 / 1 6 " C ol o n i al T r i m I nst a l l e d ( 3 12m m )
Summary of the content on the page No. 6
Specifications 7 31 / 8 ” ( 8 0 9 m m ) to 4 0 3⁄4 ” ( 10 35m m ) 3 11⁄4 ” ( 79 4m m ) 13 2 1 / 1 6 ” ( 555 m m ) 5 to 26 / 16 ” ( 66 9m m ) 13 20 / 16 ” ( 5 28 m m ) 7 22 / 1 6 ” ( 5 6 9 m m ) 2 3 ” ( 5 8 3 m m ) Figure 2: Sonnet Adjustable Surround, Classic, and Base Shelf with Riser. Table 1: Sonnet Options Dimensions. Colonial - 3 Sided Colonial - 4 Sided Classic - 3 Sided Classic - 4 Sided 13 9 13 9 Height 20 /16” (528mm) 24 /16” (624mm) 20 /16” (528mm) 24 /16” (624mm) Width 311⁄4” (794mm)
Summary of the content on the page No. 7
Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. LIGHTING AND TURNING OFF INSTRUCTIONS: H o t w h i le o p e r a t i n g . D o n o t t o u c h , s e ver e b u r n s m ay r e s u lt . K e ep ch i l d r en , c l o t h i n g , C A U T I O N : f u r n it u r e , g a so l in e o r o t h er f la m m
Summary of the content on the page No. 8
Operating Instructions The Sonnet is designed to gradually lower or raise the flame as is needed in application. It normally does not just turn on and off. This is very dependant on the size of the room the unit is located in. During the first several operational cycles the electronics go through a learning process that establishes how the system will react to the environment it is in. It does so by determining the amount of time it takes for the temperature to rise 1°. It does this several
Summary of the content on the page No. 9
Operating Instructions TIMER MODE – (appliance must be in standby mode; pilot ignited): The Timer setting allows you to set two (2) burner times and two (2) burner times every 24 hours. For to operate as a thermostat, TEMP must be set at 40°F (4.5°C) or higher. If the setting is decreased to --, the motor will turn the valve to the standby position in the moon times and await the next burner cycle. NOTE: The display shows the set temperature ever
Summary of the content on the page No. 10
Operating Instructions BLOWER SPEED: The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). Pressing the fan’s three (3) position rocker switch on the unit’s control panel will change the speed of the fan; it is Low/Off/High (refer to Figure 4). The fan can not be controlled with the handset. NORMAL SOUNDS DURING OPERATION: Table 2: Normal Sounds. Component Sound & Reason Sonnet & Surrounds Creaking when heating up or cooling down. Burner Light pop or
Summary of the content on the page No. 11
Maintenance And Service Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance, may result in property damage or personal injury. At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or
Summary of the content on the page No. 12
Maintenance And Service GLASS DOOR REMOVAL: Remove the glass door by placing the hooked end of the door release tool in the hole on the door latch mechanism (see Figure 9) and pulling the latch out then up over the lip on the door. When the two (2) latches have been released, tilt the door forward and then lift up to unhook the bottom door tabs (see Figure 10). Figure 9: Door Release. Warning: Do not touch or attempt to remove the glass if the fireplace is not completely cold. Never ope
Summary of the content on the page No. 13
Maintenance And Service CHANGING REMOTE HANDSET CODE: A code is preset for the remote handset and receiver, but can be changed if required. If one or more Sonnets are to be installed, confirm that the remote control signal codes are different for each unit.To change the code, complete the following: 1. Change DIP switch position (shown at the top of Figure 13). 2. Press and hold the receiver’s reset button (see Figure 14) until you hear two (2) acoustic signals. After the second longer acoust
Summary of the content on the page No. 14
Maintenance And Service FUEL CONVERSION: TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result c
Summary of the content on the page No. 15
Maintenance And Service b) Push the slider, with your finger or flat head screwdriver, to the left if it is to be set for natural gas or to the right for propane (see L P G to Figure 24). N G c) Turn the pilot head a 1⁄4 turn clockwise; back to its original position. 7. Convert the gas regulator: Figure 23: Turn Pilot Head. Figure 24: Settig Regulator gas type a) If unit is installed, pull to LP. the Sonnet out from the fireplace. Ensure you do not damage any of the venting or the
Summary of the content on the page No. 16
Initial Installation WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. CLEARANCES TO COMBUSTIBLES: Maintain sufficient clearances for operation, service and maintenance. • A clearance of 71⁄2” (191 mm) minimum is required from the side of the unit to the sidewalls. • A clearance of 41⁄2” (114 mm) minimum is required from the side of the unit to a 6” (152 mm) deep post/colum
Summary of the content on the page No. 17
Initial Installation B-VENT MODEL: WARNING: This appliance has been designed to operate by drawing combustion air and dilution air from the room. It is also designed to draw room air for proper heat circulation from the sides of the unit. Blocking or modifying these openings in any way can create hazardous situations, either through poor venting or by overheating. It is important that this unit has sufficient air circulation for proper venting and combustion. Provisions must be made for the
Summary of the content on the page No. 18
Initial Installation QUALIFIED INSTALLERS ONLY 3. Remove log and ember set and all wrapping material from the stove. Remove wrapping material from log and embers and check for any damage. If damage is observed, do not use unit and contact your local dealer. 4. Refractory, glass doors, screen rails, screen mesh and log grates can be removed from the fireplace before installing the Sonnet. Check that the chimney cleanouts fit properly. The flue damper can be fully blocked open or removed for i
Summary of the content on the page No. 19
Initial Installation QUALIFIED INSTALLERS ONLY b) Cut the tie strap from around the wires for the spill switch. c) Feed the connector end of both wires through the hole in the bottom left corner of the back panel (see Figure 31). d) Using needle nose pliers remove the jumper wire on the thermocouple (see Figure 32). e) Attach the connectors for the spill switch wiring to the connectors the jumper was removed from (see Figure 33). f) Re-attach the back panel. g) Using a T-20 screwdriver re
Summary of the content on the page No. 20
Initial Installation QUALIFIED INSTALLERS ONLY VENTING FIREPLACE INSERTS: The ENVIRO Sonnet may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials. Before starting, refer to INITIAL INSTALLATION - PREPARING YOUR SONNET FOR INSTALLATION and INITIAL INSTALLATION - CONVERTING A DIRECT VENT FIREPLACE TO A B-VENT FIREPLACE. Please reference th