Enviro 1700-V Insert user manual

User manual for the device Enviro 1700-V Insert

Device: Enviro 1700-V Insert
Category: Stove
Manufacturer: Enviro
Size: 3.31 MB
Added : 9/18/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Enviro 1700-V Insert. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Enviro 1700-V Insert.

For your convenience

If looking through the Enviro 1700-V Insert user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Enviro 1700-V Insert on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Enviro 1700-V Insert to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Enviro 1700-V Insert User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Enviro 1700-V Insert but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Enviro 1700-V Insert. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Venice
Wood Stove
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
Models: 1200-V & 1700-V Insert
Contact your local building or fire officials,
INSTALLER:
Leave this manual with the wood stove.
or the authority having jurisdiction about
restrictions and installation inspection
CONSUMER:
Retain this manual for future refe

Summary of the content on the page No. 2

Table of Contents Safety Precautions..........................................................................................3 Operating Instructions.....................................................................................4 Building Your Fire.................................................................................5 How It Works......................................................................................9 Specifications................................................

Summary of the content on the page No. 3

Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” WOOD STOVE, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: ● Please read this entire manual before you install and use your new woodstove. Failure to follow instructions may result in property damage, bodily injury or even death. Be aware that local Codes and Regulations may override some items in this manual. Check with your local inspector. ● If this appliance is not properly installed, operated and maintained, a ser

Summary of the content on the page No. 4

Operating Instructions FIRST START When first installed, the chimney, firebricks and steel are cold and it usually takes several hours on a fairly high burn for them to become hot and dry enough for the stove to function well. We recommend during the unit’s first burn that a door and window are opened to vent the smoke and fumes created from the unit’s paint curing. The paint will smell a little for the first burn or two as it cures. DISPOSAL OF ASHES: If you let the ashes accumulate two or t

Summary of the content on the page No. 5

Operating Instructions CREOSOTE - ITS FORMATION AND REMOVAL: When wood is burned slowly, it may produce tar and other vapors that, combined with moisture, form creosote. These vapors condense in the relatively cooler chimney flue of a slow burning fire and, if ignited, make an extremely hot fire. Therefore, the smoke pipe and chimney should be inspected bi- weekly during the heating season to determine if a build-up has occurred. If creosote has accumulated it should be removed to reduce the

Summary of the content on the page No. 6

Operating Instructions d) Regulate the heat output of the stove by adjusting the air controls to allow a larger fire and vice versa. A short period of experimentation with the control settings will allow you to regulate the heat output to keep your home comfortable. Do not use a grate or elevate the fire. Build wood fire on the stove firebox hearth floor. 3. Refueling the Stove: Use a long pair of gloves (barbecue gloves) when feeding the fire because these stoves burn at the front. They are

Summary of the content on the page No. 7

Operating Instructions g) Once the kindling has started to burn, add some smaller pieces of seasoned, dry firewood. Note: Adding large pieces at the early stages will only serve to smother the fire. Continue adding small pieces of seasoned dry firewood, keeping the door slightly open until each piece starts to ignite. Remember to always open the door slowly between placing wood into the fire. h) Once the wood has started to ignite and the smoke has reduced, close the wood stove door fully. Th

Summary of the content on the page No. 8

Operating Instructions 7. What is draft? Draft is the ability of the chimney to exhaust or draw smoke produced during the normal combustion process. Too much draft may cause excessive temperatures in the appliance and may damage the appliance. Inadequate draft may cause backpuffing or “plugging” of the chimney. There is a certain amount of draft that is required to allow for your stove to function at its’ highest efficiency. A water column gauge can be used to reference this amount. 8. What

Summary of the content on the page No. 9

Operating Instructions HOW IT WORKS: E x h a u s t S m o ke C o n v ec t io n H e a t 1 / 2 " C e r am ic b a f f le ; r ef le ct s h e a t d o w n t o b u r n t h e p ar t icl es P r i m a r y a i r ; win d o w i n t h e sm o ke. a i r w as h ( c o o l er a i r t o k e e p t h e g l as s c le an ) . S eco n d ar y air t u bes ; c r e a t es a s eco n d b ur n o n t h e p a r t ic l e s in t he sm o ke f o r a m o r e ef f icien t & cl ea n er b ur n . R a d ian t H ea t P i l o t air t h r o u

Summary of the content on the page No. 10

Specifications AIR CONTROL: The air wash and pilot air (control the amount of air to the fire) are controlled by the rod located on the right side of the unit. To increase your air, pull the rod out and to decrease, push the rod in. All the units have a secondary air that flows through the tubes at the top of the firebox, just below the baffles. Pull this control all the way out when first starting the stove. Once the fire has been established you may adjust this control to set the burn rat

Summary of the content on the page No. 11

Specifications CLEARANCES TO COMBUSTIBLES - 1200-V INSERT: Table 2: 1200-V Insert Clearance to Combustibles. A Minimum clearance to an unshielded side wall 10” (254 mm) B Minimum clearance to an unshielded 8” (203 21” (533 mm) mm) mantel C Minimum top facing (protruding 3⁄4” [19 mm]) 171⁄2” (445 mm) � � clearance D Minimum side facing (protruding 3⁄4” [19 mm]) � 1” (25 mm) clearance � E † From front of door opening to edge of floor USA 16” (406 mm) protection CND 18” (450 mm) � � F † From sid

Summary of the content on the page No. 12

Specifications CLEARANCES TO COMBUSTIBLES - 1700-V INSERT: Table 5: 1700-V Insert Clearance to Combustibles. A Minimum clearance to an unshielded side wall 10” (254 mm) B Minimum clearance to an unshielded 8” (203 24” (610 mm) mm) mantel C Minimum top facing (protruding 3⁄4” [19 191⁄2” (495 mm) � � mm]) clearance D Minimum side facing (protruding 3⁄4” [19 � 1” (25 mm) mm]) clearance � E † From front of door opening to edge of floor USA 16” (406 mm) protection CND 18” (450 mm) � �

Summary of the content on the page No. 13

Specifications DIMENSIONS - 1200-V INSERT: 13 5 2 2 / 16 " ( 5 6 6 m m ) 13 3 4 / 16 " ( 8 8 5 m m ) 9 2 1 / 16 " ( 54 8 m m ) 3 4 7 / 8 " ( 1 2 0 3 m m ) 5 1 3 / 16 " ( 3 3 8 m m ) 5 " ( 12 7m m ) 15 26 / 16 " 1 1 9 / 16 " ( 6 84m m ) ( 484 m m ) 7 2 0 / 8 " o r 7 ( 52 9m m ) 2 0 / 8 " 9 1 9 / 16 " ( 530 m m ) ( 497 m m ) 1 2 0 / 16 " ( 509 m m ) 1 5 21 / 16 " ( 5 5 7m m ) Figure 4: 1200-V Insert Dimensions.

Summary of the content on the page No. 14

5 2 2 / 16 " ( 566m m ) 13 34 / 16 " ( 88 5m m ) 1 26 / 8 " ( 6 63 m m ) 3 47 / 8 " ( 1 2 0 3m m ) 7 1 7 / 1 6 " ( 4 5 3 m m ) 5 " ( 12 7 m m ) 15 26 / 16 " ( 684m m ) 1 1 9 / 1 6 " ( 4 84 m m ) 7 2 0 / 8 " 7 o r 2 0 / 8 " ( 5 2 9 m m ) 9 1 9 / 1 6 " ( 53 0m m ) ( 4 97 m m ) 9 2 4 / 16 " ( 62 4m m ) 1 2 6 / 2 " ( 67 2 m m ) Figure 5: 1700-V Insert Dimensions. Specifications DIMENSIONS - 1700-V INSERT: 14

Summary of the content on the page No. 15

Installation Please read and understand these instructions before installing pedestal or ash pan and leg option. Failure to follow these instructions carefully could cause personal injury or property damage. All screws are pre-installed on the base of the unit. REMOVAL FROM PALLET: • Remove the bricks from the unit before starting. • Remove the two (2) lag bolts (shown in Figure 6) that secure the unit to the pallet from inside the firebox. Note: Before the bricks are installed, rivets (Fig

Summary of the content on the page No. 16

Installation MASONRY FIREPLACE INSTALLATION: Unless you are experienced, we recommend installation by your dealer or a professional installer. Install only in a masonry fireplace with a good-condition chimney at least 15 ft (4.6 m) high, both of which have been constructed in accordance with the building code. Refer to Tables 4 and 7 for minimum masonry fireplace dimensions. Be sure the fireplace and chimney are clean and sound without any cracks or loose mortar. Do not remove any bricks or

Summary of the content on the page No. 17

Installation The flue collar is removable for installations into fireplaces with low openings. a) Remove the rear two (2) secondary air tube and C-Cast Ceramic Baffles, if installed (see C-CAST CERAMIC BAFFLE INSTALLATION). Remove the secondary air tubes by placing a screwdriver (any style except flat head) into one of the air holes and tapping it with a hammer/mallet to U S A 16” ( 4 0 6 m m ) the left. C N D 1 8” ( 4 50 m m ) 8 " b) Unscrew the two (2) nuts on top of the F l oo r P r

Summary of the content on the page No. 18

Installation Figure 14: Removable flue collar in place. 4. Screw or nail the provided metal plate with the wording “THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED PERSON L e v el i n g L e g s PRIOR TO THE RE-USE AS A CONVENTIONAL Figure 15: Leveling legs. FIREPLACE.” to the inside of the fireplace. SURROUND PANEL SEALED INSTALLATION FOR USA ONLY: Note: Though this is an allowable installation, we do not recommend it because of the p

Summary of the content on the page No. 19

Installation INSTALLATION USING A BLOCK-OFF PLATE FOR USA ONLY: If this unit is to be installed into a masonry fireplace or a zero-clearance fireplace with a direct connection you must install a non-combustible seal-off device such as a block-off plate or damper adapter. By installing a block-off plate you seal the chimney, ensuring that no smoke enters the home and sealing the chimney to encourage draft. To construct a block-off plate follow the below steps. 1. Determine where the block-off

Summary of the content on the page No. 20

Installation 5. Mount the block-off plate using masonry screws in a masonry fireplace and sheet metal screws on a zero- clearance fireplace (screws M a nt e l need only be long enough to penetrate the first layer of S ta i n l e s s s te e l c h i m ney metal). D a m pe r m u s t c o n n e c to r m u s t e x t end b e r em o v e d 1 2 " ( 3 0 5 m m ) p a s t the 6. Insulate the block-off plate b l o c k - o f f p l a te . using high - temperature B l ock - o f f pl at e o r fiberglass i


Alternative user manuals
# User manual Category Download
1 Enviro 50-1095 User manual Stove 1
2 Enviro 50-1220 User manual Stove 3
3 Enviro 50-1096 User manual Stove 0
4 Enviro 50-1266 User manual Stove 0
5 Enviro 50-1221 User manual Stove 1
6 Enviro 2100 Freestanding User manual Stove 0
7 Enviro 50-1574 User manual Stove 0
8 Enviro 50-1675 User manual Stove 0
9 Enviro 50-1385 User manual Stove 0
10 Enviro 50-1386 User manual Stove 0
11 Enviro 50-1573 User manual Stove 0
12 Enviro BERN C-10629 User manual Stove 0
13 Enviro C-10365 User manual Stove 0
14 Enviro C-10608 User manual Stove 0
15 Enviro C-10792 User manual Stove 0
16 Edelbrock 2006-2007 (N) User manual Stove 4
17 Aarrow Fires SF 50 User manual Stove 1
18 Aarrow Fires EcoBurn BK043 User manual Stove 0
19 Aarrow Fires EcoBurn AFS1221 User manual Stove 0
20 Aga Ranges Berrington User manual Stove 3