Enviro 50-1096 user manual

User manual for the device Enviro 50-1096

Device: Enviro 50-1096
Category: Stove
Manufacturer: Enviro
Size: 2.67 MB
Added : 6/16/2014
Number of pages: 31
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Enviro 50-1096. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Enviro 50-1096.

For your convenience

If looking through the Enviro 50-1096 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Enviro 50-1096 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Enviro 50-1096 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Enviro 50-1096 User manual - Online PDF
Advertisement
« Page 1 of 31 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Enviro 50-1096 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Enviro 50-1096. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Sienna
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
WHAT TO DO IF YOU SMELL GAS
This appliance is
only for use with
• Open windows/extinguish any open flame.
the type of gas
• Do not try to light any appliance.
indicated on the
• Do not touch any electrical switch or use any
rating plate. This
phone in your building.

Summary of the content on the page No. 2

Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, do not allow anyone who is in accordance with their instructions. Carefully read all unfamiliar with the stove to operate it. the instructions in this manual first. Consult the building • To prevent injury, if the pilot or pilot and authority having jurisdiction to determine the need for burn

Summary of the content on the page No. 3

Table of Contents Safety Precautions.....................................................................................................2 Table of Contents......................................................................................................3 Codes And Approvals.................................................................................................4 Specifications............................................................................................................

Summary of the content on the page No. 4

Codes And Approvals DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. BV: This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L vent. May also be vented through a conventional chimney using a chimne

Summary of the content on the page No. 5

Specifications RATING LABEL LOCATION: The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the fireplace. DIMENSIONS: Table 1: Sienna exterior dimensions. (Shaded dimensions shown in Figure 1 & 2.) Surround Style Distance Direct Vent B-Vent 11 9 Arched Surround From Flue To Surround 14 /16” (376 mm) 14 /16” (370 mm) 5 From Back/Sensor To Surround 17 /16” (439 mm) 18 7⁄8” (479 mm) 33” x 46” (840 x 1930 mm) From Flue To Surround 14 1⁄

Summary of the content on the page No. 6

Specifications 21" ( 5 33 m m ) S en s or S how n : B - V e n t w i th 3 3 " x 4 6" ( 84cm x 193 c m ) sur r ou nd pan e l w i t h t r i m F l u e 3 1 7 / 8 " ( 441 m m ) 1 13 / 1 6 " ( 333 m m ) 1 3 W i t h T r i m 4 6 / 8 " ( 1 17 1 m m ) 1 / 8 " W i tho ut T r i m 46" ( 1 16 8 m m ) ( 36 m m ) W i th T r i m 3 3 3 / 1 6 " ( 3 4 3 m m ) W i th o u t T r i m 3 3 " ( 3 3 8 m m ) 1 30 / 2 " ( 7 75 m m ) 11 3 22 / 16 " 2 2 / 4 " 1 ( 576 m m ) ( 5 77 m m ) 15 / 1 6 " ( 38 3 m m ) 5 2 0 / 8 " ( 5 2

Summary of the content on the page No. 7

L O I P T O L T P T H T P T H I P F F Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. PILOT LIGHTING INSTRUCTIONS: H o t wh i l e o p e r a t i n g . D o n o t t o u c h , s ever e b u r n s m ay r e su lt . K e ep c h i l d r e n , cl o t h ing , C A U T I O N : f u r n i t u r e , g a so l

Summary of the content on the page No. 8

Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating BURNER LIGHTING: A) Make sure the pilot is lit. B) Turn gas control knob COUNTER CLOCKWISE to ON. C) Flip the burner switch to ON. D) Turn HI/LO knob to the desired flame height. E) Turn on all electrical power to the unit. NOTE: Check that all burner holes are lit. Figure 5. Control panel. TURN OFF UNIT: Flip switch to OFF to turn off burners only. If the fireplace is to be turned off

Summary of the content on the page No. 9

Maintenance And Service Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance, may result in property damage or personal injury. At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or

Summary of the content on the page No. 10

Maintenance And Service TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY FUEL CONVERSION: Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qual

Summary of the content on the page No. 11

Initial Installation WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. CLEARANCES TO COMBUSTIBLES: Maintain sufficient clearances for operation, service and maintenance. • A clearance of 25 1⁄2” (648 mm) minimum is required from the center of the unit to the sidewalls. • A 2” (51 mm) wide mantel can be mounted at a 1 0" ( 254m m) M an t l e minimum height of 39” (991 mm) fr

Summary of the content on the page No. 12

Initial Installation WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. MINIMUM FIREPLACE SIZE: Table 2: Minimum dimensions of fireplace for Sienna to be installed into. Description of Fireplace Dimension Direct Vent B-Vent At Back 23 1⁄4” (591 mm) 23 1⁄4” (591 mm) Width At Front 35” (889 mm) 35” (889 mm) With Surround Only 23 3⁄4” (603 mm) 23 3⁄4” (603 mm) Height With Surro

Summary of the content on the page No. 13

Initial Installation QUALIFIED INSTALLERS ONLY DIRECT VENT MODEL: WARNING: This appliance has been designed to draw room air for proper heat circulation from the sides of the unit. Blocking or modifying the louvers in any way can create hazardous situations. This model is vented with two (2) 3” aluminum or stainless steel flex vent leading into a co-linear to co-axial vent adaptor and using a vertical termination cap. The flue collars of this model will fit inside of standard 3” vent and ma

Summary of the content on the page No. 14

Initial Installation QUALIFIED INSTALLERS ONLY VENTING FIREPLACE INSERTS: The ENVIRO SIENNA may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non- combustible materials. Before starting refer to PREPARING YOUR SIENNA FOR INSTALLATION and CONVERTING A DIRECT VENT FIREPLACE TO A B-VENT FIREPLACE. An approved chimney liner and rain cap must be used. A throat conne

Summary of the content on the page No. 15

Initial Installation QUALIFIED INSTALLERS ONLY ELECTRICAL REQUIREMENTS: The fan is thermostatically controlled and it will o o 1 2 0 F ( 4 9 C ) not operate if the appliance is cold. A few minutes T e m p e r a t ur e S e n sor F a n C o n t r o l after the appliance is lit and the variable speed control is set at a desired setting, the fan will C N T4 C N T 1 automatically turn on. The fan will automatically B l a c k turn off after the appliance has cooled down. W hi te The fireplace must

Summary of the content on the page No. 16

L O I P T O L T P T H T P T H I P F F Initial Installation QUALIFIED INSTALLERS ONLY GAS LINE CONNECTION: Warning: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. Gas Line Connection: •This fireplace is equipped with a certified flexible pipe located on the right side of the unit, terminating in a 3⁄8” male NPT fitting. Consult the local authorities for local codes or use the CAN/CGA B149 (1 or 2) installation code in Canada. In the U

Summary of the content on the page No. 17

Initial Installation QUALIFIED INSTALLERS ONLY CONVERTING A DIRECT VENT FIREPLACE TO A B-VENT FIREPLACE: 1. Remove the Direct Vent chimney connector assembly by taking out the two (2) T-20 screws at the front of the unit. Push the assembly out from under the brackets at the back and remove (see Figure 16). Di r e ct V e n t 2. Remove the two (2) fresh air C o n ne c t or A s s e m bl y inlet covers from each side. Cover locations shown in Figure 16. 3. Slide the B-Vent chimney connect

Summary of the content on the page No. 18

Secondary Installation QUALIFIED INSTALLERS ONLY REPLACING THE BLOWER: 1. Turn the unit off and allow the unit to cool completely. 2. Remove the fascia or louvers, open the door (see “DOOR REMOVAL”), and remove the log set. 3. Remove the log support tray by lifting the back of the tray up and pull it out from under the lip. Take care to not knock the pilot and the side brick panels. 4. Remove the centre and top brick panels (see “REMOVING THE BRICK PANEL”). 5. Turn gas supply off and remove ga

Summary of the content on the page No. 19

Secondary Installation DOOR REMOVAL: Open the door by removing the 5 two (2) /16’’ bolts located at the top outside corners of the glass frame (see Figure 19). Lift the bottom of the door up and remove from unit (see Figure 20). CAUTION GLASS MAY SEPARATE FROM DOOR. Figure 20: Bottom hooks for glass Figure 19: Top bolts for glass door. door. INSTALLATION OF SURROUND PANEL: The Sienna must have one of the panels installed around the unit; the unit panel, the filler panel, or the filler pa

Summary of the content on the page No. 20

Secondary Installation LOG SET AND EMBER INSTALLATION: NOTE: The logs are fragile and should be handled gently. The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner, and a few of the logs come with locator pins, notches and ledges, which make alignment easier. Using the pictures provided, carefully set the logs in place (see Figures 24 through 29). Figure 24: The first log to be placed is the bac


Alternative user manuals
# User manual Category Download
1 Enviro EG40-071 Owner's manual Stove 0
2 Enviro EG40-071 Owner's manual Stove 0
3 Enviro 50-1221 Specification Stove 0
4 Enviro 50-1095 User manual Stove 1
5 Enviro 50-1220 User manual Stove 3
6 Enviro 50-1266 User manual Stove 0
7 Enviro 50-1221 User manual Stove 1
8 Enviro 2100 Freestanding User manual Stove 0
9 Enviro 50-1574 User manual Stove 0
10 Enviro 50-1675 User manual Stove 0
11 Enviro 50-1385 User manual Stove 0
12 Enviro 50-1386 User manual Stove 0
13 Enviro 50-1573 User manual Stove 0
14 Enviro 1700-V Insert User manual Stove 0
15 Enviro BERN C-10629 User manual Stove 0
16 Edelbrock 2006-2007 (N) User manual Stove 4
17 Aarrow Fires SF 50 User manual Stove 1
18 Aarrow Fires EcoBurn BK043 User manual Stove 0
19 Aarrow Fires EcoBurn AFS1221 User manual Stove 0
20 Aga Ranges Berrington User manual Stove 3