England's Stove Works TRANQUILITY 50TVL17 user manual

User manual for the device England's Stove Works TRANQUILITY 50TVL17

Device: England's Stove Works TRANQUILITY 50TVL17
Category: Stove
Manufacturer: England's Stove Works
Size: 1.65 MB
Added : 6/16/2014
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for England's Stove Works TRANQUILITY 50TVL17. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with England's Stove Works TRANQUILITY 50TVL17.

For your convenience

If looking through the England's Stove Works TRANQUILITY 50TVL17 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual England's Stove Works TRANQUILITY 50TVL17 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual England's Stove Works TRANQUILITY 50TVL17 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
England's Stove Works TRANQUILITY 50TVL17 User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual England's Stove Works TRANQUILITY 50TVL17 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to England's Stove Works TRANQUILITY 50TVL17. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TRANQUILITY WOOD STOVE 


 
INSTALLATION & OPERATION MANUAL 
17‐VL, 50‐SVL17 & 50‐TVL17 
      



Manufactured By: 
England’s Stove Works, Inc. 

PO Box 206 

Monroe, VA 24574 


REV. 9/2010



CAUTION
Please read this entire manual before installation and use of this wood fuel‐
burning appliance.  Keep children, furniture, fixtures and all combustibles away 
from any heating appliance. 
SAFETY NOTICE
Failure to follow these instructions can result in property damag

Summary of the content on the page No. 2

IMPORTANT: IF YOU HAVE A PROBLEM WITH THIS UNIT, DO  NOT RETURN IT TO THE DEALER.  CONTACT TECHNICAL  SUPPORT @ 1‐800‐245‐6489  Mobile Home Use:  This freestanding wood unit is approved for mobile home or  doublewide installation with the outside combustion air hook‐ up.  See the “Installation” section of this manual for details  pertaining to mobile home installations.  Mobile home  installation must be in accordance with the Manufactured  Home and Safety Standard (HUD), CFR 3280, Part 24. 

Summary of the content on the page No. 3

TABLE OF CONTENTS    Introduction  Operation  • Introduction ................................. 4  • Break‐In Fires ............................. 17  • Lighting a Fire ............................. 17    • Continuous Operation................ 18  Specifications  • Safety Notes ............................... 19  • Heating Specifications .................. 5    • Dimensions ................................... 5  • EPA Compliance ........................... 5  Maintenance  • Important Notes........

Summary of the content on the page No. 4

INTRODUCTION    Thank you for purchasing this fine product from England’s Stove Works!    England’s Stove Works was started, and is still owned by, a family that  believes strongly in a “Do It Yourself” spirit; that’s one reason you  found this product at your favorite “Do It Yourself” store.    We intentionally design and build our stoves so that any homeowner  can maintain their unit with basic tools, and we’re always more than  happy to show you how to do the job as easily and as inexpensivel

Summary of the content on the page No. 5

SPECIFICATIONS    Heating Specifications  • Maximum Heat Output ...................................................................... 40,000 BTU/hr  • Maximum Burn Time** ................................................................................ 6 hours  • Approximate Square Footage Heated*** ..................................... 500 ‐ 1200 sq. ft.  • Firebox Capacity ....................................................................................... 45 pounds  • Flue Collar .........

Summary of the content on the page No. 6

INSTALLATION  Installation Overview  When choosing a location for your new stove, there are a multitude of factors that  should be taken into account before beginning the installation.    1. Traffic Patterns – To help prevent accidents, the stove should be placed in a location  where it is out of the way of normal travel through the home.    2. Heat Flow – When deciding on a location for the stove, consider the way heat moves  throughout your home.  Install the stove where you need the heat; b

Summary of the content on the page No. 7

• INSTALLATION  Clearances to Combustibles    Parallel Wall Installation      D C   A    B            Corner Installation    E F     Chimney  Chimney  Chimney  Unit to Side  Connector  Connector  Unit to  Unit to  Connector  Wall  to Side  to Rear  Rear Wall  Corner  to Corner    Wall  Wall    A  B  C  D  E  F    in. (mm.)  in. (mm.)  in. (mm.)  in. (mm.)  in. (mm.)  in. (mm.)  Single Wall Chimney  12   19.5  12  10  7   15   Connector  (304.8)  (495.3)  (304.8)  (254.

Summary of the content on the page No. 8

  INSTALLATION    Venting Introduction    This wood stove operates on a  Venting Guidelines  natural draft system, in which the chimney  • ALWAYS install vent pipe in strict  system pulls air through the stove.  This unit  adherence to the instructions and  must be installed in accordance with the  clearances included with your  following detailed descriptions of venting  venting system.  techniques; not installing the stove in  • DO NOT connect this wood stove to  accordance with the details li

Summary of the content on the page No. 9

INSTALLATION    Additional Venting Information  • Do not mix and match components from different pipe manufacturers when assembling  your venting system (i.e. Do NOT use venting pipe from one manufacturer and a thimble  from another).  • We require a minimum chimney height of 15.0 ft.  Chimney systems shorter than this  may not create the amount of draft which is required to operate this wood burning unit.  • Do not use makeshift compromises when installing the venting system; have existing  chi

Summary of the content on the page No. 10

INSTALLATION    Wall Pass‐Throughs  In Canada, the installation must conform to CAN/CSA‐B365 when passing through combustible construction. Page | 10

Summary of the content on the page No. 11

INSTALLATION Approved Venting Method 1: Through the Wall Factory Built Chimney 10 ft. Termination Cap The 10‐3‐2 Rule: The chimney system  Storm Collar  must terminate 3.0 ft. above the point  where its centerline passes through the  roof AND the chimney must terminate  2.0 ft. above any part of the dwelling  Roof Flashing  within a 10 ft. radius of the chimney.  Class A Chimney System Wall Thimble  Tee and Tee Support  Chimney Connector  (Single or Double Wall)  • Prefabricated chimney sy

Summary of the content on the page No. 12

INSTALLATION Approved Venting Method 2: Through the Ceiling 10 ft. Termination Cap The 10‐3‐2 Rule: The chimney system  must terminate 3.0 ft. above the point  where its centerline passes through the  roof AND the chimney must terminate  2.0 ft. above any part of the dwelling  within a 10 ft. radius of the chimney.  Storm Collar  Class A Chimney System Roof Flashing  Ceiling Support Box  Chimney Connector  (Single or Double Wall)  • Prefabricated chimney systems must conform to UL‐103HT 

Summary of the content on the page No. 13

INSTALLATION Approved Venting Method 3: Internal or External Masonry Chimney System 10 ft.  The 10‐3‐2 Rule: The chimney system  must terminate 3.0 ft. above the point  where its centerline passes through the  Chimney liner cross‐sectional  roof AND the chimney must terminate  area (Length x Width) must be  2.0 ft. above any part of the dwelling  within a 10 ft. radius of the chimney.  no larger than twice the cross‐ sectional area of the flue collar  2  2 (2 x 28.27 in = 56.5

Summary of the content on the page No. 14

INSTALLATION  WARNING  DO NOT INSTALL IN A SLEEPING ROOM.  Caution  CAUTION  NEVER draw outside combustion air from:  THE STRUCTURAL INTEGRITY OF THE  Wall, floor or ceiling cavity or  MANUFACTURED HOME FLOOR, WALL AND  enclosed space such as an attic, garage or crawl  space.  CEILING/ROOF MUST BE MAINTAINED.  Mobile Home Installation  • The wood stove MUST be secured to the floor of the mobile home using lag bolts and the holes  provided in the bottom of the unit for this  Chimney Cap/Spark Arr

Summary of the content on the page No. 15

FLOOR PROTECTION • This wood stove requires a non‐combustible floor protector if the stove is to be installed on a  combustible floor.  If the floor the stove is to be installed on is already non‐combustible (i.e. a  concrete floor in a basement), no floor protection is needed (although a decorative floor protector  can still be used for aesthetic reasons).  • When using any floor protector, consider that this stove is not only heavy but will induce heating  and cooling cycles on the floor pr

Summary of the content on the page No. 16

FLOOR PROTECTION R Value Calculation  An easy means of determining if a proposed alternate floor protector meets requirements is  to follow this procedure:  1) Convert specification to R‐value:  i R‐value is given – no conversion is needed   ii k‐factor is given with a required thickness (T) in inches:  R = 1/k x T  iii C‐factor is given:  R = 1/C  2) Determine the R‐value of the proposed alternate floor protector:  i Use the correct formula given in step 1 (above) to convert values not express

Summary of the content on the page No. 17

OPERATION  Break‐In Fires  • This wood burning unit is constructed of heavy gauge steel and cast iron and is built to last a  long time.  However, in order to ensure no excessive thermal stresses are induced on the metal  during the first fire, three break‐in fires should be burned, each one slightly hotter than the last.   These break‐in fires will not only help the stove body acclimate to the high temperatures of the  fire, but will also slowly cure the high temperature stove paint, which will

Summary of the content on the page No. 18

  OPERATION  • England’s Stove Works, Inc. always recommends the use of a magnetic stove thermometer, so  that the temperature of the unit can be monitored.  When using a magnetic stove thermometer,  locate the thermometer above the door on either the left or right side of the stove and use the  following temperatures as rough guidelines to determine the burn rate and heat output level of  the stove:  o Normal wood stove operation should occur between 350°F (177°C) and 550°F (288°C),  with 350°F

Summary of the content on the page No. 19

OPERATION  Additional Safety Guidelines  • The installation of smoke detectors is highly recommended when installing this or any other  solid fuel burning appliance.  Smoke detectors should be located near or in every room of the  home, particularly sleeping rooms.  • A smoke detector can be installed in the same room as this cordwood burning unit; installing the  smoke detector too close to the unit can lead to nuisance alarms due to slight wisps of smoke  emitted during the fire starting or re

Summary of the content on the page No. 20

  MAINTENANCE  Daily Maintenance  • Inspect the firebox for ash accumulation; remove excess ash and follow instructions  below regarding disposal.  Ash should not be allowed to accumulate in the stove to the  point that it covers the coal bed air inlets.  Monthly Maintenance  • Check the blower for dust accumulation (if installed); check the door handle for proper  operation and to be certain an airtight seal is still being made by the door.  • Inspect the chimney system and chimney connector an


Alternative user manuals
# User manual Category Download
1 England's Stove Works 10-CPM User manual Stove 3
2 England's Stove Works 13-NCL 50-SNC13L 50-TNC13L User manual Stove 0
3 England's Stove Works 13-NCG 50-SNC13G 50-TNC13G User manual Stove 0
4 England's Stove Works 13-NCC 50-SNC13C 50-TNC13C User manual Stove 2
5 England's Stove Works 13-NCP 50-SNC13P 50-TNC13P User manual Stove 0
6 England's Stove Works 24-JC User manual Stove 0
7 England's Stove Works 24-ICD User manual Stove 0
8 England's Stove Works 25-EP User manual Stove 0
9 England's Stove Works 26-GBVNG User manual Stove 0
10 England's Stove Works 26-GBVLP User manual Stove 0
11 England's Stove Works 25-PI User manual Stove 2
12 England's Stove Works 25-EPI User manual Stove 1
13 England's Stove Works 18-MH User manual Stove 0
14 England's Stove Works 40-TRCPM User manual Stove 0
15 England's Stove Works 49-SHC22 User manual Stove 1
16 Edelbrock 2006-2007 (N) User manual Stove 4
17 Aarrow Fires SF 50 User manual Stove 1
18 Aarrow Fires EcoBurn BK043 User manual Stove 0
19 Aarrow Fires EcoBurn AFS1221 User manual Stove 0
20 Aga Ranges Berrington User manual Stove 3