Dayton 3VG80 user manual

User manual for the device Dayton 3VG80

Device: Dayton 3VG80
Category: Stove
Manufacturer: Dayton
Size: 0.37 MB
Added : 10/26/2014
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Dayton 3VG80. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Dayton 3VG80.

For your convenience

If looking through the Dayton 3VG80 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Dayton 3VG80 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Dayton 3VG80 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Dayton 3VG80 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Dayton 3VG80 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Dayton 3VG80. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operating Instructions & Parts Manual
3VG80
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
®
Dayton Propane
Construction Heater
Description
Fire,
Dayton Model 3VG80 heater is a variable 65,000, 85,000, and 100

Summary of the content on the page No. 2

Dayton Operating Instructions and Parts Manual 3VG80 ® Dayton Propane Construction Heater General Safety Information This product • This product has been approved for contains and/or Make certain you read and understand all use in the Commonwealth of Massa- generates chemicals know to the State chusetts. warnings. Keep these instructions for of California to cause cancer or birth • Use only the hose and factory preset reference. They are your guide to safe and defects, or other reproductive harm

Summary of the content on the page No. 3

Dayton Operating Instructions and Parts Manual Model 3VG80 General Safety Information • To prevent injury, wear gloves when (Continued) handling heater. • Never attach duct work to heater. • Locate heater on stable and level • Do not alter heater. Keep heater in surface if heater is hot or operating. its original state. • Never block air inlet (rear) or air • Do not use heater if altered. outlet (front) of heater. • Turn off propane supply to heater • Keep heater away from strong and unplug when

Summary of the content on the page No. 4

Dayton Operating Instructions and Parts Manual 3VG80 ® Dayton Propane Construction Heater Product Identification Hot Air Outlet (Front) Handle Fan Guard Motor Mount Power Cord Control Knob Inlet Connector Hose /Regulator Assembly Figure 2 - Product Identification 4

Summary of the content on the page No. 5

Dayton Operating Instructions and Parts Manual Model 3VG80 Theory of Operation Propane Supply THE IGNITION SYSTEM THE FUEL SYSTEM Propane gas and propane tank(s) must be The spark transformer ignitor lights the provided by the customer. main burner. The hose/regulator assembly attaches to the propane gas supply. The propane gas THE AUTOMATIC CONTROL SYSTEM Use this heater only with a propane vapor moves through the automatic control valve This system causes the heater to shut withdrawal supply s

Summary of the content on the page No. 6

Dayton Operating Instructions and Parts Manual 3VG80 ® Dayton Propane Construction Heater Ventilation Hose 4. Open propane supply valve on propane Fuel Gas tank(s) slowly. Supply Connector Follow the mini- Valve NOTE: If not opened slowly, excess-flow mum fresh, outside check valve on propane tank will stop gas air ventilation requirements. If proper fresh, outside air ventilation is not flow. If this happens, close propane supply provided, carbon monoxide poisoning valve and open again slowly.

Summary of the content on the page No. 7

Dayton Operating Instructions and Parts Manual Model 3VG80 Operation (Continued) 2. Inspect heater before each use. Check Storage connections for leaks. Apply mixture of 5. Plug extension cord into a 120 Volt/60 Disconnect heater liquid soap and water to connections. from propane Hertz, 3-hole, grounded outlet. Motor Bubbles forming show a leak. Correct supply tank(s). will start. Fan will turn, forcing air out all leaks at once. front of heater. 1. Store propane tank(s) in safe manner. 3. Inspe

Summary of the content on the page No. 8

Dayton Operating Instructions and Parts Manual 3VG80 ® Dayton Propane Construction Heater Maintenance (Continued) 6. Carefully pull motor and fan out of shell. 14. Carefully route motor wires through hole in shell (See Figure 8). Place IMPORTANT: Be careful not to damage motor, motor mount, and fan guard fan. Do not set motor and fan down with Transformer into rear of heater shell. Green Lead the weight resting on fan. This could damage fan pitch. 15. Insert screws through heater shell and Pow

Summary of the content on the page No. 9

Dayton Operating Instructions and Parts Manual Model 3VG80 4. Remove ignitor from rear head. Maintenance (Continued) 5. Install new ignitor. Attach ignitor to Ignitor Wire 5. Place setscrew on flat of shaft. Tighten rear head with ignitor mounting screw. setscrew firmly (40-50 inch-pounds). 6. Attach ignitor wire. 6. Place motor, motor mount, and fan 7. Check gap between ignitor electrode guard into rear of heater shell (See and target plate. Gap should be .13" Bushing Motor, page 8, steps 14 th

Summary of the content on the page No. 10

Dayton Operating Instructions and Parts Manual 3VG80 ® Dayton Propane Construction Heater Accessories Description Part No. Regulator LPA2150 Hose and Regulator Assembly LPA3100 10' Hose Assembly LPA1000 Fuel Gas Connector LPA4020 Wiring Diagram 100,000 BUT/HR MODEL Motor White Black Green Green Green Power Cord White Black Terminal Board Black White Ignition White Control 12 Black 34 56 Orange Green 7 8 Relay Blue Ignitor Blue Thermal Switch Blue Thermocouple Auto Control Valve Figure 14 - Elect

Summary of the content on the page No. 11

Dayton Operating Instructions and Parts Manual Model 3VG80 Troubleshooting Chart Never attempt to service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur. Symptom Possible Cause(s) Corrective Action Fan does not turn when heater is plugged 1. No electrical power to heater 1. Check voltage to electrical outlet. If in voltage is good, check heater power cord for breaks 2. Fan hitting inside of heater shell 2. Adjust motor m

Summary of the content on the page No. 12

Dayton Operating Instructions and Parts Manual 3VG80 ® For Repair Parts, call 1-800-323-0620 Dayton Propane 24 hours a day - 365 days a year Please provide following information: Construction Heater -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P.O. Box 3074 1657 Shermer Road Northbrook, IL 60065-3074 U.S.A. Figure 15 - Repair Parts Illustration 12

Summary of the content on the page No. 13

Dayton Operating Instructions and Parts Manual Model 3VG80 Repair Parts List Use only original replacement parts. This heater must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries. This will also protect your warranty coverage for parts replaced under warranty. Reference Number Description Part No. Quantity 1 Base Tray 102362-01 1 2 *Hex TPG Screw, 10-16 X 38 M11084-26 15 3 Base 103917-01AA 1 4 Nozzle 099138-02 1

Summary of the content on the page No. 14

3VG80 Dayton Operating Instructions and Parts Manual Dayton Propane Construction Heater LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. Dayton propane construction heater, Models covered in this manual, are warranted by Dayton Electric Mfg. Co. (Dayton) to the original user against defects in workmanship or materials under normal use for one year after date of purchase. Any part which is determined to be defective in material or workmanship and returned to an authorized service location, as D


Alternative user manuals
# User manual Category Download
1 Edelbrock 2006-2007 (N) User manual Stove 4
2 Aarrow Fires SF 50 User manual Stove 1
3 Aarrow Fires EcoBurn BK043 User manual Stove 0
4 Aarrow Fires EcoBurn AFS1221 User manual Stove 0
5 Aga Ranges Berrington User manual Stove 3
6 Air King 4TM64A/9515A User manual Stove 3
7 Amana BIGOVEN ACF4215A User manual Stove 8
8 Amana Gas - Easy Touch Control Range User manual Stove 1
9 Amana BIGOVEN ACF4225A User manual Stove 4
10 Amana BIGOVEN DCF4205 User manual Stove 0
11 Amana BIGOVEN ACF4205A User manual Stove 0
12 Amana BIGOVEN ACF422GA User manual Stove 1
13 Amerec PKLE 182 User manual Stove 0
14 Amerec PKLE 2018 User manual Stove 0
15 Amerec PKLE 2024 User manual Stove 0