Avalon Stoves Avalon PelletAstoria PS user manual

User manual for the device Avalon Stoves Avalon PelletAstoria PS

Device: Avalon Stoves Avalon PelletAstoria PS
Category: Stove
Manufacturer: Avalon Stoves
Size: 1.12 MB
Added : 12/4/2013
Number of pages: 42
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Avalon Stoves Avalon PelletAstoria PS. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Avalon Stoves Avalon PelletAstoria PS.

For your convenience

If looking through the Avalon Stoves Avalon PelletAstoria PS user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Avalon Stoves Avalon PelletAstoria PS on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Avalon Stoves Avalon PelletAstoria PS to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Avalon Stoves Avalon PelletAstoria PS User manual - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Avalon Stoves Avalon PelletAstoria PS but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Avalon Stoves Avalon PelletAstoria PS. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Astoria
Pellet Stove
• Horizontal Or Vertical Vent
• Freestanding Stove
• Mobile Home Approved
• Class A Chimney Retrofit
• Hearth Stove into Existing
Masonry Chimney , Masonry
Fireplace, or Z.C. Fireplace
-- Please read this entire manual before
installation and use of this pellet fuel-
burning room heater. Failure to follow
these instructions could result in
property damage bodily injury or even
death.
-- Contact local building or fire officials
about restrictions and installation
inspection

Summary of the content on the page No. 2

2 Introduction Introduction We welcome you as a new owner of an Astoria pellet heater. In purchasing an Astoria you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The Astoria is one of the finest home heaters the world over. This manual will explain the installation, operation, and maintenance of this pellet-burning heater. Please familiarize yourself with the Owner's Manual before operat

Summary of the content on the page No. 3

Table of Contents 3 Introduction Operation (continued) Introduction......................................................2 Manual Mode.....................................................21 Important Information .........................................2 Auto Mode........................................................22 Restrictor Adjustment.........................................23 Safety Precautions Adjusting the Fan Speed......................................23 Safety Precautions ..........

Summary of the content on the page No. 4

Gas 4 Safety Precautions • Do not operate the • Contact your local building heater if you smell officials to obtain a permit smoke coming from and information on any the heater. Turn the installation restrictions or MODE switch to inspection requirements Ok "OFF", monitor your in your area. Notify your heater, and call your insurance company of this dealer. heater as well. • Never use gasoline, • The exhaust system must gasoline-type lantern fuel, be completely airtight and kerosene, charcoal

Summary of the content on the page No. 5

Safety Precautions 5 • The heater will not operate • This heater must be during a power outage. If connected to a standard a power outage does 115 V., 60 Hz grounded occur, check the heater electrical outlet. Do not for smoke spillage and use an adapter plug or open a window if any sever the grounding plug. smoke spills into the room. Do not route the electrical cord underneath, in front of, or over the heater. • Keep foreign objects out • When installed in a mobile ? of the hopper. home, the

Summary of the content on the page No. 6

6 Specifications Heating Specifications: Approximate Maximum Heating Capacity (in square feet)*.................................800 to 2,250 Sq. Feet Burn Rate (Pounds per Hour)**.......................................................................1.7 to 5.5 Maximum Burn Time on Low Burn** ................................................................67.5 Hours Hopper Capacity............................................................................................115 Pounds * Heating capa

Summary of the content on the page No. 7

Installation 7 Before You Begin READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. Check with local building officials for any permits required for installation of this pellet heater and notify your insurance company before proceeding with installation. Packing List • Thermostat & Wire • Scraper Rod Tool • Brush • Fuses (2) Installation Options: • Residential or Mobile Home

Summary of the content on the page No. 8

8 Installation Clearances - Straight Installation Through the Wall Installations Interior Vertical Vents A A AAAAAAAAA 3” A A A AAAAAAA A Minimum 2” A A A AAAAAAA A Minimum “Tee” 3” Minimum A AAAAAAA A AAAAAAAA A AAAAAAA A A AAAAAA A A AAAAAAA A 9” Minimum A AAAAAA A A AAAAAAA A 9” Minimum A AAAAAAAAAAAA A A AAAAAAAAAAAAAA A A AAAAAAAAAAAA A A AAAAAAAAAAAAAA A A AAAAAAAAAAAA A A AAAAAAAAAAAAAA A A AAAAAA A A AAAAAAA A Floor Protection 6” Minimum 6” Minimum A AAAAAA A A AAAAAAA A AAAAAAAA AAAAA

Summary of the content on the page No. 9

Installation 9 Venting the Pellet Stove • PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE TO ANY COMBUSTIBLE (INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER). • DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE. • DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. • USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT THROUGH WALLS AND A CEILING SUPPORT/FIRE STOP SPACER WHEN PASSING THE VENT THROUGH CEILINGS (MAKE SURE TO MAINTAIN 3

Summary of the content on the page No. 10

10 Installation Pellet Vent Type • Must be 4" diameter Type "L"(except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney. All vent joints (including adapters, elbows, etc…) must be sealed with 500° F. RTV silicone. Installing the Pellet Vent Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of 500° F. RTV silicone into the gap between sections. • Horizontal sections must have a 1/4" rise every 12" of tra

Summary of the content on the page No. 11

Installation 11 Mobile Home Requirements • Outside air is required (used for combustion) - see the directions below. • The heater must be bolted to the b floor (Some states do not require this; check with your local building Use the lag bolts (used department). See the illustration to secure the stove to to the right. the pallet) to screw the pedestal to the floor. • The heater must be grounded to the steel chassis of the mobile home (Some states do not require 7/16” this; check with your l

Summary of the content on the page No. 12

12 Installation Alcove Installation Requirements When the pellet stove is placed in a location where the ceiling height is less than 7' tall, it is considered an alcove installation. Because of the reduced height, the requirements listed below must be met. • Minimum height is 60" • Maximum depth is 48" • Minimum width is 46" • Minimum clearance of 9" on each side and 3" on back Baffle Installation Install the baffles included with the stove (see page 29 for details). Door Seal Verification The

Summary of the content on the page No. 13

Installation 13 Installation Example: Direct "Through-the-wall" Installation Horizontal Rain Cap Type "L" Outside Air Vent 12” Minimum House Shield - prevents discoloration to outside of home - HIGHLY RECOMMENDED AAAAAAAAAAAAA A AAAAAAAAAAAAA AA A Seal each vent AAAAAAAAAAAAA AA A section (including AAAAAAAAAAAAA A 3” Minimum adapters, elbows, Wall Thimble (note AAAAAAAA A 3” clearance etc...) by injecting a between vent and A AAAAAA A A liberal amount of combustibles) 500° F. RTV A A

Summary of the content on the page No. 14

14 Installation Installation Example: Interior Vertical Installation AAAAAAAAAAAA A 2” 3” AAAAAAA A Minimum Minimum A AAAAA A A “Tee” Outside A AAAAA A A Type "L" Vent Air (optional) A AAAAA A A A AAAAA A A A AAAAAA AAAAA A A 9” Minimum A AAAAAA AAAAA A A A AAAAAA AAAAA A A AAAAA A Floor Protection 6” Minimum A AAAAA A AAAAAAA Vertical Cap 24” Minimum Storm Collar AAAAAAAAAAAAAA AAAAAAAAAAAAAA Roof Flashing AAAAAAAAAAAAAA AAAA AAAAAAAAAAAAAA A AA A Insulation must maintain 3” clearance. A

Summary of the content on the page No. 15

Installation 15 Installation Example: Class A Chimney Retrofit AAAAAAAAAAAAAAA AA AAAAAAAAA AA 2” 3” Minimum Minimum A AAAAAAA A AA “Tee” A AAAAAAA A AA Outside A AAAAAAA A AA Air Type "L" Vent (optional) A AAAAAAA A AA A AAAAAAA A AA A AAAAAAA A AA 9” Minimum A AAAAAAAAAAAAAA A AA A AAAAAAAAAAAAAA A AA A AAAAAAAAAAAAAA A A AAAAAAA A Floor Protection 6” Minimum A AAAAAAA A Seal each vent AAAAAAAAA section (including adapters, elbows, AAAAAA etc...) by injecting a A AAAAAAAA A liberal amo

Summary of the content on the page No. 16

16 Installation Installation Example: Masonry Fireplace Hearth Stove Vertical Cap “L” Vent Cover Plate (non-combustible) Storm Collar Seal the cover plate with silicone. AAAAA AAAA AAAAAAAA AA AAAAA AAAAAAAAAA AAAA Seal each vent section (including AAAA AAAA AA A A AAAAA AAAA adapters, elbows, A AA A AAAA AAAA AAAAAA AAAA A AA A etc...) by injecting a A AA A AAAAAA AA A A AAAAAAA A AA A liberal amount of “L” Vent Flex 500° F. RTV AAAA AAAA AA A A AAAAA AAAA Section silicone into the gap

Summary of the content on the page No. 17

Installation 17 Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove Vertical Cap Cover Plate (non-combustible) Storm Collar Seal the cover plate with silicone. “L” Vent Seal each vent AA section (including AA adapters, elbows, etc...) by injecting a AAAA AA AAAA liberal amount of A AA A AA A AA A 500° F. RTV A AA A AA A AA A silicone into the gap AAAA AA AAAA between sections. AAAA AA “L” Vent Flex AAAA AA AAAAA Section Allow room for the AAAA AA AAAAA hopper lid to o

Summary of the content on the page No. 18

18 Installation Installation Example: Freestanding Masonry Chimney Vertical Cap “L” Vent Cover Plate (non-combustible) Storm Collar Seal the cover plate with silicone. AAAA AAAA AAAAAAA AA AAAA AAAAAAAAA AA AA AAAA AA AAAA AA AAAA AAA AAAA AAAAAA AAAA AAAA AAAA AAAAAA A A A Seal each vent section (including A AA A AAAA AA AAAA AA AAAAAA A A A adapters, elbows, AAAA AAAA AA AAAA AAAA AAAAAA AAA etc...) by injecting a AAAAAA AAAA AAAA AA AAAAAA liberal amount of 500° F. RTV AAAA AA AAAA AA

Summary of the content on the page No. 19

Operation 19 Safety Notice Read this entire manual (especially the "Safety Precautions" on pages 4 and 5) before using this stove. Failure to follow the instructions may result in property damage, bodily injury, or even death. ! Do not unplug the stove to turn it off. This stove relies upon electricity to push the flue gases out the pellet vent – unplugging it may lead to smoke entering your room. ! Failure to maintain your heater will lead to a restricted combustion air system, leading to poo

Summary of the content on the page No. 20

s t l e l 20 Operation Loading Pellets Lift the hopper lid to its vertical position. Pour pellets into the hopper until full. NOTE: The hopper holds approximately 115 pounds of pellets. To Close the Hopper Lid: lift the lid, pull this tab forward, then lower the lid down. To Open the Hopper Lid: These notches allow lift the hopper lid from this handle. you to open the hopper lid to the level you wish. AAAAAAAAAAAAAAA AAAAAAA AAAAAAAAAAAAA AAAAAAA Make sure pellets AAAAAAAAAAAAA AAAAAAA AAA


Alternative user manuals
# User manual Category Download
1 Avalon Stoves CHELAN B-VENT 700 B-VENT User manual Stove 4
2 Avalon Stoves 99200149 User manual Stove 2
3 Avalon Stoves Pellet Burning User manual Stove 1
4 Avalon Stoves 790 User manual Stove 2
5 Avalon Stoves Freestanding User manual Stove 1
6 Avalon Stoves Cedar EF User manual Stove 0
7 Avalon Stoves Spokane 1250 User manual Stove 0
8 Avalon Stoves Arbor PS User manual Stove 0
9 Avalon Stoves Spokane 1750 User manual Stove 0
10 Avalon Stoves User manual Stove 0
11 Avalon Stoves Tree of Life User manual Stove 0
12 Avalon Stoves Wood Burning& Insert User manual Stove 2
13 Avalon Stoves ZC Kit User manual Stove 0
14 Avalon Stoves 1190 User manual Stove 0
15 Avalon Stoves Arbor User manual Stove 1
16 Edelbrock 2006-2007 (N) User manual Stove 4
17 Aarrow Fires SF 50 User manual Stove 1
18 Aarrow Fires EcoBurn BK043 User manual Stove 0
19 Aarrow Fires EcoBurn AFS1221 User manual Stove 0
20 Aga Ranges Berrington User manual Stove 3