Vermont Casting D232 user manual

User manual for the device Vermont Casting D232

Device: Vermont Casting D232
Category: Indoor Fireplace
Manufacturer: Vermont Casting
Size: 0.43 MB
Added : 7/29/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Vermont Casting D232. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Vermont Casting D232.

For your convenience

If looking through the Vermont Casting D232 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Vermont Casting D232 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Vermont Casting D232 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Vermont Casting D232 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Vermont Casting D232 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Vermont Casting D232. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Free-Standing
Direct Vented
Fireplaces
MODEL D232
Installation Instructions & Homeowner's Manual
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
DO NOT STORE
* Do not try to light any appliance.
OR USE GASOLINE OR OTHER
* Do not touch any electric switch
FLAMMABLE VAPOURS AND LIQUIDS
* Do not use any phone in your building.
IN

Summary of the content on the page No. 2

TABLE OF CONTENTS PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation Instructions.................................................................................................. 3 Important Curing/Burn Information ......................................................

Summary of the content on the page No. 3

INSTALLATION AND OPERATING INSTRUCTIONS This gas fireplace should be installed by a qualified installer in IMPORTANT: accordance with local building codes and with current CAN / PLEASE REVIEW THE FOLLOWING CGA-B149 (. 1 or .2) Installation codes for Gas Burning Fireplaces and Equipment and CAN/CSA Z 240 .4 Canada. CAREFULLY Remove any plastic from trim parts before turning the fireplace ON. FOR U.S.A Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1. It is n

Summary of the content on the page No. 4

FIREPLACE DIMENSIONS MODEL D232 A K D C G E I J F H B MODEL D232 A 25" 635mm 1/8" B 24 613mm C 16" 406mm D 20" 508mm E 19" 483mm F 21" 533mm 3/4" G 31 806mm 3/4" H 17 451mm 5/8" I 29 752mm J 9" 229mm 1/2" K6 165mm L— — M— — N— — - 4 -

Summary of the content on the page No. 5

GAS SPECIFICATIONS PREPARATION The use of wall paper adjacent to this fire- MAX. MIN. INPUT INPUT place is not recommended, as the high heat MODEL FUEL GAS CONTROL B.T.U.H B.T.U.H. given off by this fireplace may adversely effect the binders in the adhesive used to D232RN Natural Gas Millivolt Hi/Lo 30,000 21,000 apply the wallpaper. D232RP Propane Gas Millivolt Hi/Lo 30,000 22,500 Before beginning, remove the glass door from the fireplace. Also check to make sure there is no hidden damage to

Summary of the content on the page No. 6

L I P TP TPTH TH When using copper or flex connector use only approved INSTALLATION OF REMOTE fittings. Always provide a union when using back iron pipe so that gas line can be easily disconnected for burner SWITCH FOR RN/RP GAS VALVE or fan servicing. See Fig. 2. See gas specification for Install on/off switch assembly on either the rear right or left pressure details and ratings. side of the Fireplace. The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolat

Summary of the content on the page No. 7

V Openable GENERAL VENTING INFORMATION Your fireplace is approved to be vented either through the There must not be any obstruction such as bushes, garden side wall, or vertically through the roof. sheds, fences, decks or utility buildings within 24" from the – Only venting components specifically approved and front of the termination hood. labelled for this fireplace may be used. Do not locate termination hood where excessive snow or – Minimum clearances between vent pipes and com- ice build u

Summary of the content on the page No. 8

Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Recessed Location Outside Corner D B = C C Combustible A = 6"(152mm) Combustible E A 6"(152mm) Noncombustible V V 2"(50mm) Noncombustible 2"(50mm) V B Balcony - Balcony - with no side wall with perpendicular side wall C = Maximum depth of 48" (1219mm) for recessed H G location. V V D = Minimum width for back wall o

Summary of the content on the page No. 9

GENERAL INFORMATION ON ASSEMBLING THE VENT PIPES TWIST LOCK PIPES CRIMPED END PIPES When using twist lock pipe it is not necessary to use Before joining elbows and pipes apply a bead of high sealant at the twist lock joints. temperature sealant to crimped end of elbow or pipe. (Fig. 6). The only areas of the venting that need to be sealed with Join pipes and secure joints with three (3) sheetmetal high temperature silicone sealant are the collars on the screws. (See Fig. 6) Wipe off excess sea

Summary of the content on the page No. 10

For each 45 degree elbow installed in the hori- VERTICAL SIDEWALL INSTALLATIONS zontal run, the length of the horizontal run MUST be reduced by 18" (45cm). This does not Since it is very important that the venting system apply if the 45 degree elbows are installed on maintain its balance between the combustion air intake the vertical part of the vent system. and the flue gas exhaust, certain limitations as to vent o The maximum number of elbow degrees in a system is 270 configurations apply and

Summary of the content on the page No. 11

VERTICAL DIMENSION FROM THE FLOOR OF THE FIREPLACE TO THE CENTRE OF THE HORIZONTAL VENT PIPE VERTICAL DIMENSION FROM THE FLOOR OF THE FIREPLACE TO THE CENTRE OF THE HORIZONTAL VENT PIPE SIDEWALL VENTING GRAPH TO USE THE VENT GRAPH (Dimensions in Feet) 1. Determine the height of the centre of the horizontal For FSDV42 vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph (Fig. 12 ), locate 30 the point it intersects with the slanted graph line. 29 2. From the

Summary of the content on the page No. 12

STEP 3 VENT PIPE ASSEMBLY Place fireplace into position. (Fig. 17). Measure the vertical length (X) required from the base of the flue collars to the STEP 1 centre of the wall opening. Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or non- combustible, cut opening to size. Fig. 13 or 15. (For combustible walls first frame in opening. Fig. 14). Vent Opening — Combustible

Summary of the content on the page No. 13

STEP 7 STEP 5 Apply high temperature sealant to 4" and 7" collars or the Measure the horizontal length requirement including a 2" termination one inch away from crimped end. Guide the overlap , i.e. from the elbow to the outside wall face plus 2" vent terminations 4" and 7" collars into their respective vent (or the distance required if installing a second 90) elbow. pipes. Double check that the vent pipes overlap the collars (Fig. 19). by 2". Secure the termination to the wall with screw

Summary of the content on the page No. 14

Ensure sidewall venting clearances are observed. DO NOT BACK FILL AROUND SNORKEL. SOIL SHOULD NOT BE LESS THAN 4" If installing a snorkel a minimum 24" vertical rise is BELOW SNORKEL. necessary. The maximum horizontal run with the 24" vertical pipe is 36" (915mm). This measurement is taken from the collar of the fireplace to the face of the exterior wall. See vent graph for extended horizontal FOUNDATION run if the vertical exceeds 24". RECESS SNORKEL 1. Establish vent hole through the wal

Summary of the content on the page No. 15

TO INSTALL VERTICAL VENTING VERTICAL THRU THE ROOF APPLICATIONS 1. Locate your fireplace. c) A minimum of an 8 ft. vertical rise. 2. Plumb to centre of the (4") flue collar from ceiling d) Two sets of 45 degree elbow offsets within these above and mark position. vertical installations. From 0 to a maximum of 8 ft. of 3. Cut opening equal to 9-3/8" x 9-3/8" (240 mm x 240 mm). vent pipe can be used between elbows. (Fig. 25) 4. Proceed to plumb for additional openings through the e) 7DVCS must b

Summary of the content on the page No. 16

CRIMPED ENDS VENTING COMPONENTS Starter Kit -Model 7DVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Venting for 7DVSKV-A order 1/12 to 6/12 roof pitch for 7DVSKV-B order 7/12 to 12/12 roof pitch for 7DVSKV-F order flat roof Starter Kit - Model 7TDVSKS -Snorkel Kit for Below Grade Installation 45º elbow kit 7DVT45 for Vertical Installation Offsets 90º transition elbow kit 7DVRT90 for Vertical Sidewall Applications or thru-the-roof. Telescopic vent sections 7DVP610 - 6" to 10" adju

Summary of the content on the page No. 17

TWIST LOCK VENTING COMPONENTS Starter Kit -Model 7TDVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDVSKV-F order flat roof Starter Kit - Model 7TDVSKS -Snorkel Kit for Below Grade Installation 45º elbow kit 7TDV45 for Vertical Installation Offsets 90º transition elbow kit 7TDVRT90 for Vertical Sidewall Applications or thru-the-roof. Telescopic vent sections 7TDVP1218 - 12" to 18"

Summary of the content on the page No. 18

OPERATING INSTRUCTIONS GENERAL GLASS INFORMATION GLASS REMOVAL D232 Only glass approved for use in with this product 1 . Remove frame window brass trim (See Trim Removal may be used for replacement. section) 1. The use of substitute glass will void all product 2. Remove remaining bottom 3/8" nut at the bottom of the warranties. frame window. 2. Care must be taken to avoid breakage of the glass. 3. Remove 3/8" nut from each side of the frame window Under no circumstances should this fireplace (Fi

Summary of the content on the page No. 19

GLASS CLEANING It will be necessary to clean the glass periodically. During start-up condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non-ammonia household cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleane

Summary of the content on the page No. 20

I O L L MAINTENANCE FLAME ADJUSTMENT (RN/RP MODELS) For units equipped with Hi/Lo valves, flame adjustment 1. It is important to keep the burner and the burner is accomplished by rotating the Hi/Lo adjustment knob compartment clean. This must be done periodically, at located near the centre of the gas control. (Fig. 38 & 39) least once per season. (See Cleaning Procedure). 2. Clean the brass trim using a soft clean cloth, slightly dampened with lemon oil and buff with a soft clean cloth. Do NOT


Alternative user manuals
# User manual Category Download
1 Vermont Casting 2080 User manual Indoor Fireplace 2
2 Vermont Casting 2170 User manual Indoor Fireplace 0
3 Vermont Casting 2160 User manual Indoor Fireplace 0
4 Vermont Casting 2547CE User manual Indoor Fireplace 1
5 Vermont Casting 3031 User manual Indoor Fireplace 0
6 Vermont Casting 20DVT User manual Indoor Fireplace 1
7 Vermont Casting 3032 User manual Indoor Fireplace 0
8 Vermont Casting 2465 User manual Indoor Fireplace 0
9 Vermont Casting 2466 User manual Indoor Fireplace 0
10 Vermont Casting 3033 User manual Indoor Fireplace 0
11 Vermont Casting 3030 User manual Indoor Fireplace 0
12 Vermont Casting 3225 User manual Indoor Fireplace 0
13 Vermont Casting 3232 User manual Indoor Fireplace 0
14 Vermont Casting 3350 User manual Indoor Fireplace 0
15 Vermont Casting 3360 User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1