Hearth and Home Technologies SL-550TRS-IPI-E user manual

User manual for the device Hearth and Home Technologies SL-550TRS-IPI-E

Device: Hearth and Home Technologies SL-550TRS-IPI-E
Category: Indoor Fireplace
Manufacturer: Hearth and Home Technologies
Size: 7.88 MB
Added : 9/20/2014
Number of pages: 85
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hearth and Home Technologies SL-550TRS-IPI-E. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hearth and Home Technologies SL-550TRS-IPI-E.

For your convenience

If looking through the Hearth and Home Technologies SL-550TRS-IPI-E user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hearth and Home Technologies SL-550TRS-IPI-E on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hearth and Home Technologies SL-550TRS-IPI-E to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hearth and Home Technologies SL-550TRS-IPI-E User manual - Online PDF
Advertisement
« Page 1 of 85 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hearth and Home Technologies SL-550TRS-IPI-E but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hearth and Home Technologies SL-550TRS-IPI-E. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Models:
SL-750TRS-IPI-E
SL-550TRS-IPI-E
SL-350TRS-D
SL-350TRS-IPI
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with
and maintenance these instructions for safe
party responsible for use
instructions included. installation and operation.
and operation.
WARNING
WARNING: If the information in these
HOT! DO NOT TOUCH.
instructions is not followed exactly, a fi re
SEVERE BUR

Summary of the content on the page No. 2

Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Heat & Glo gas appliance This Owner’s Manual should be retained for future —an elegant and clean alternative to wood burning reference. We suggest that you keep it with your other important documents and product manuals. appliances. The Heat & Glo gas appliance you have selected is designed to provide the utmost in safety, The

Summary of the content on the page No. 3

Table of Contents 1 Listing and Code Approvals 9 Gas Information A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 B. Glass Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 C. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. G

Summary of the content on the page No. 4

Listing and Code Approvals 1 1 A. Appliance Certifi cation C. BTU Specifi cations Models Maximum Minimum Orifi ce MODELS: SL-750TRS-IPI-E,SL-550TRS-IPI-E, U.S. (0-2000 ft.) or Input Input Size SL-350TRS-D, SL-350TRS-IPI Canada (2000-4500 ft.) BTU/h BTU/h (DMS) LABORATORY: Underwriters Laboratories, Inc. (UL) U.S. 30,800 20,200 #37 SL-750TRS-IPI-E (NG) TYPE: Direct Vent Gas Appliance Heater Canada 27,720 18,180 #38 U.S. 30,700 23.300 #52 STANDARD: ANSI Z21.88a-2007 • CSA 2.33a-2007 S

Summary of the content on the page No. 5

Inspection Note: The following requirements reference various The state or local gas inspector of the side wall horizon- Massachusetts and national codes not contained in this tally vented gas fueled equipment shall not approve the document. installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed G. Requirements for the Commonwealth of in accordance with the provisions of 248 CMR 5.08(2)(a)1 Massachusetts through 4. For all side wall

Summary of the content on the page No. 6

Getting Started 2 2 A. Design and Installation Considerations C. Inspect Appliance and Components Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of WARNING the building and all exhaust gases expelled to the out- Inspect appliance and components for damage. side. No additional outside air source is required. Damaged parts may impair safe operation. • Do NOT install damaged components. • Do NOT install incomplete components. CAUTIO

Summary of the content on the page No. 7

Framing and Clearances 3 3 Note: WARNING • Illustrations reflect typical installations and are FOR Fire Risk DESIGN PURPOSES ONLY. Provide adequate clearance: • Illustrations/diagrams are not drawn to scale. • Around air openings • Actual installation may vary due to individual design preference. • To combustibles • For service access A. Selecting Appliance Location Locate appliance away from traffi c areas. When selecting a location for your appliance it is important to NOTE: For actual

Summary of the content on the page No. 8

insulation. If the appliance is being installed on a cement B. Constructing the Appliance Chase slab, a layer of plywood may be placed underneath to pre- A chase is a vertical boxlike structure built to enclose the vent conducting cold up into the room. gas appliance and/or its vent system. Vertical vents that run on the outside of a building may be, but are not re- C. Clearances quired to be, installed inside a chase. Construction of the chase may vary with the type of build- WARNING ing. Th

Summary of the content on the page No. 9

D. Elevated Hearth Systems Use the table below to identify the hearth system that will be used. The table will also help identify effects on the various dimensions. Some hearth systems will elevate the appliance off the fl oor at a given dimension. For example, if appliance will be used with a Kenwood Cabinet with Base, the appliance will be elevated 9-1/4 inches. The 9-1/4 inch elevation will also have to be added to the following: Extension Wall Hole referenced in Figure 6.3 (Exterior W

Summary of the content on the page No. 10

E. Mantel Projections All measurements are in inches. CEILING 1/2 IN. MINIMUM 12 11 10 9 2-7/8 IN. 8 7 32 MINIMUM 3 FT. MAXIMUM 6 5 Note: Clearance from opening 13 4 12 to perpendicular wall. 11 3 10 9 8 7 6 5 4 Figure 3.5 Clearances to Mantel Legs or Wall Projections (Acceptable on both sides of opening.) TOP OF HOOD OR FIREPLACE OPENING Figure 3.3 Clearances to mantels or other combustibles above appliance 1/2 in. SHEETROCK 3-1/2 in. NON-COMBUSTIBLE 3 IN. BOARD SHIPPED MINIMUM WITH AP

Summary of the content on the page No. 11

Termination Locations 4 4 HORIZONTAL A. Vent Termination Minimum Clearances OVERHANG 2 FT. 20 INCHES MIN. WARNING VERTICAL MIN. WALL LOWEST Fire Risk. DISCHARGE OPENING Explosion Risk. GAS DIRECT VENT TERMINATION CAP Maintain vent clearance to combustibles as specifi ed. X 12 • Do not pack air space with insulation or other materials. ROOF PITCH IS X/ 12 Failure to keep insulation or other materials away from vent pipe may cause fi re. H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHAR

Summary of the content on the page No. 12

M N P R Q (See Note 2) V T S S Electrical V V Service D* V = VENT TERMINAL X V = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED A = 12 inches.................clearances above grade, veranda, L** = 7 ft. ......................... clearance above paved (See Note 1) (See Note 1) porch, deck or balcony sidewalk or a paved driveway located on public property B = 12 inches.................clearances to window or door M*** = 18 inches................ clearance under veranda, porch, that

Summary of the content on the page No. 13

Vent Information and Diagrams 5 5 A. Vent Table Key The abbreviations listed in this vent table key are used in the vent diagrams. Symbol Description Vertical First section (closest to appliance) of vertical length V1 Second section of vertical length V2 First section (closest to appliance) of horizontal length H1 8-1/2 in. Second section of horizontal length H2 WARNING Horizontal Fire Hazard. Explosion Risk. Figure 5.1 Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue

Summary of the content on the page No. 14

D. Use of Flex Vent The fl ex vent must be supported with TERMINATION the spacing between support intervals CAP 3in. CLEARANCE not exceeding 4 feet, with no more than ½ inch sag between supports. A support is required at each change in venting direction, and in any location where it is necessary to maintain the necessary clearance to combustibles. FLEX-VENT A simple “up and out” installation (Fig- ure 5.3) requires only enough support to maintain the necessary clearance 1in. to combustib

Summary of the content on the page No. 15

E. Vent Diagrams WARNING Fire Risk. Explosion Risk. Do NOT pack insulation or other combustibles between ceiling fi restops. • ALWAYS maintain specifi ed clearances around venting and fi restop systems. • Install wall shield and ceiling fi restops as specifi ed. Failure to keep insulation or other material away from vent pipe may cause fi re. 1. Top Vent - Horizontal Termination Venting H Maximum 1 V Minimum One Elbow SL-350TRS-D SL-550, SL-750TRS-E 90º Elbow 1-1/2 ft. 457 mm 1 ft. 305 mm Note: Use

Summary of the content on the page No. 16

Two Elbows H Maximum V Minimum Note: Use SL-D Series SL-350TRS-D, SL-550TRS-E, SL-750TRS-E components only. 90º Elbow NOT ALLOWED 1/2 ft. 152 mm 1 ft. 305 mm 1-1/2 ft. 457 mm 2 ft. 610 mm Note: There MUST be a 25% reduction in total H when using 2-1/2 ft. 762 mm 4 ft. 1.2 m fl ex vent except when using the 3-1/2 ft. 1.1 m 6 ft 1.8 m simple up and out installation 4-1/2 ft. 1.4 m 14 ft. 4.3 m (see Figure 5.3). H + H Maximum= 14 ft. (4.3 m) 1 2 V + H + H Maximum= 40 ft. (12.2 m) 1 1 2 WARNING

Summary of the content on the page No. 17

1. Top Vent - Horizontal Termination - (continued) H Maximum H + H Maximum H Maximum H + H Maximum 1 1 2 1 1 2 V Minimum Three Elbows 1 Model: SL-350TRS-D Models: SL-550TRS-IPI-E, SL-750TRS-IPI-E Elbow only 1-1/2 ft. 457 mm 2 ft. 610 mm 1 ft. 305 mm 2 ft. 610 mm 1/2 ft. 152 mm 2 ft. 610 mm 4 ft. 1.2 m 2 ft. 610 mm 4 ft. 1.2 m 1-1/2 ft. 457 mm 3 ft. 914 mm 6 ft. 1.8 m 3 ft. 914 mm 6 ft. 1.8 m 2-1/2 ft. 762 mm 5 ft. 1.5 m 10 ft 3.0 m 5 ft. 1.5 m 10 ft. 3.0 m 3-1/2 ft. 1.1 m 7 ft. 2.1 m 14 ft. 4.

Summary of the content on the page No. 18

Exhaust restrictor Instructions 2. Top Vent - Vertical Termination 1. Install the exhaust restrictor over the center of the ex- haust outlet in the fi rebox (see Figure 5.8). No Elbow 2. Center the exhaust restrictor in the open end of the exhaust outlet and secure through the slots on the ex- Note: Use SL-D Series haust restrictor with the 2-1/4 in. self tapping screws components only. provided in the appliance manual bag. Note: If installing a vertical vent/termination off the top of the a

Summary of the content on the page No. 19

2. Top Vent - Vertical Termination - (continued) Two 90º Elbows H Maximum H Maximum V V + V Minimum 1 1 2 1 2 V Minimum 1 SL-350TRS-D SL-550TRS-E, SL-750TRS-E * * 90º Elbow 1-1/2 ft. 457 mm 1 ft. 305 mm * * 1/2 ft. 152 mm 2 ft. 610 mm 2 ft. 610 mm * * 1 ft. 305 mm 2-1/2 ft. 762 mm 2-1/2 ft. 762 mm * * 2 ft. 610 mm 4 ft. 1.2 m 4 ft. 1.2 m * * 3 ft. 914 m 6 ft. 1.8 m 6 ft. 1.8 m * * 4 ft. 1.2 m 8 ft. 2.4 m 8 ft. 2.4 m * * 5 ft. 1.5 m 15 ft. 4.6 m 15 ft 4.6 m * * H Maximum= 15 ft. (4.6 m) 1 V +

Summary of the content on the page No. 20

2. Top Vent - Vertical Termination - (continued) Three 90º Elbows ALL MODELS Note: Use SL-D Series V H + H Maximum V V + V Minimum 1 1 2 2 1 2 components only. 90º Elbow 0 0 1-1/2 ft. 457 mm 1-1/2 ft. 457 mm 1/2 ft.. 152 mm 1 ft. 305 mm * * * * Note: There MUST be a 25% 1-1/2 ft. 457 mm 2 ft. 610 mm * * * * reduction in total H when using 2-1/2 ft. 762 mm 4 ft. 1.2 m * * * * fl ex vent except when using the simple up and out installation 3-1/2 ft. 1.1 m 6 ft. 1.8 m * * * * (see Figure


Alternative user manuals
# User manual Category Download
1 Hearth and Home Technologies 3100-I User manual Indoor Fireplace 4
2 Hearth and Home Technologies 6000G-IPI User manual Indoor Fireplace 0
3 Hearth and Home Technologies 6000G-LP User manual Indoor Fireplace 0
4 Hearth and Home Technologies 6000G User manual Indoor Fireplace 0
5 Hearth and Home Technologies 6000GBV User manual Indoor Fireplace 0
6 Hearth and Home Technologies 6000G-IPILP User manual Indoor Fireplace 0
7 Hearth and Home Technologies 6000GBV-IPI User manual Indoor Fireplace 1
8 Hearth and Home Technologies 6000 Series User manual Indoor Fireplace 0
9 Hearth and Home Technologies 6000GCF-IPIL User manual Indoor Fireplace 0
10 Hearth and Home Technologies 6000GCF-IPI User manual Indoor Fireplace 0
11 Hearth and Home Technologies 6000GBV-IPILP User manual Indoor Fireplace 0
12 Hearth and Home Technologies 6000GL-IPI-R User manual Indoor Fireplace 0
13 Hearth and Home Technologies 6000GBV-LP User manual Indoor Fireplace 0
14 Hearth and Home Technologies 6000GL-IPI-S User manual Indoor Fireplace 0
15 Hearth and Home Technologies 6000GL-IPILP-S User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1