Hearth and Home Technologies Heatilator GDST5244I user manual

User manual for the device Hearth and Home Technologies Heatilator GDST5244I

Device: Hearth and Home Technologies Heatilator GDST5244I
Category: Indoor Fireplace
Manufacturer: Hearth and Home Technologies
Size: 6 MB
Added : 9/20/2014
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hearth and Home Technologies Heatilator GDST5244I. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hearth and Home Technologies Heatilator GDST5244I.

For your convenience

If looking through the Hearth and Home Technologies Heatilator GDST5244I user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hearth and Home Technologies Heatilator GDST5244I on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hearth and Home Technologies Heatilator GDST5244I to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hearth and Home Technologies Heatilator GDST5244I User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hearth and Home Technologies Heatilator GDST5244I but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hearth and Home Technologies Heatilator GDST5244I. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Model(s):
GDST5244I
GDST5244IL
Direct Vent Gas Appliance
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow • Leave this manual with
• Important operating and
these instructions for safe party responsible for
maintenance instructions
installation and operation. use and operation.
included.
WARNING WARNING
HOT SURFACES!
If the information in these instruc-
Glass and other surfaces are hot during
tions is not followed exac

Summary of the content on the page No. 2

Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. This owner’s manual should be retained for future reference. A. Congratulations We suggest that you keep it with your other important Congratulations on selecting a Heatilator gas fi replace, an documents and product manuals. elegant and clean alternative to wood burning fi replaces. The information contained in this owner’s manual, unless The Heatilator gas fi replace you h

Summary of the content on the page No. 3

Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Used to address practices not related to personal injury. Table of Contents A. Congratulations 2 6 Termination Locations B. Warranty 5 A. Vent Termi

Summary of the content on the page No. 4

14 Appliance Setup A. Remove Fixed Glass Assembly 44 B. Remove the Shipping Materials 44 C. Clean the Appliance 44 D. Accessories 44 E. Install the Log Set 44 F. Place the Rockwool 46 G. Place the Lava Rock and Vermiculite 46 H. Fixed Glass Assembly 46 I. Firescreen 46 J. Install Trim and/or Surround 46 K. Air Shutter Setting 46 15 Troubleshooting A. Intellifi re Ignition System 47 16 Reference Materials A. Appliance Dimension Diagram 49 B. Vent Components Diagrams 50 C. Service Parts 57 D.

Summary of the content on the page No. 5

B. Warranty Hearth & Home Technologies LIMITED WARRANTY Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or Canada. Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts. Warranty Period HHT Manufactured Appliances and Venting Components Covered EPA Parts Labor

Summary of the content on the page No. 6

B. Warranty (continued) This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or corrosion on any of the metal surfaces, cast iron components, baffl es, fi repots, doors, or fi rebox area are not covered by this warranty. Noise resulting from minor expansion, contraction, or movement of certain parts is normal and

Summary of the content on the page No. 7

Listing and Code Approvals 1 1 A. Appliance Certifi cation C. BTU Specifi cations See Through GDST5244 MODELS: GDST5244I, GDST5244IL IPI LABORATORY: Underwriters Laboratories, Inc. (UL) Max/Min Input Rate (NG) 48,000/34,000 TYPE: Vented Gas Fireplace Heaters Orifi ce Size (NG) .136 in./3.45 mm STANDARD: ANSI Z21.88-2005•CSA2.33-2005•UL307B Max/Min Input Rate (LP) 43,000/31,600 Orifi ce Size (LP) .076 in./1.93 mm This product is listed to ANSI standards for “Vented Gas Fireplace Heaters” and a

Summary of the content on the page No. 8

Inspection Note: The following requirements reference various The state or local gas inspector of the side wall horizon- Massachusetts and national codes not contained in this tally vented gas fueled equipment shall not approve the document. installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed H. Requirements for the Commonwealth of in accordance with the provisions of 248 CMR 5.08(2)(a)1 Massachusetts through 4. For all side wall

Summary of the content on the page No. 9

Mantel User Guide Operating Instructions 2 2 • Install a physical barrier such as: A. Gas Fireplace Safety - A decorative fi rescreen. - Adjustable safety gate. WARNING • Install a switch lock or a wall/remote control with child HOT SURFACES! protection lockout feature. Glass and other surfaces are hot • Keep remote controls out of reach of children. during operation and cool down. • Never leave children alone near a hot fi replace, whether Hot glass will cause burns. operating or cooling do

Summary of the content on the page No. 10

C. Fan Kit (optional) F. Fixed Glass Assembly If desired, a fan kit may be added. Contact your dealer to See Section 14.H. order the correct fan kit. G. Remote Controls, Wall Controls and Wall D. Clear Space Switches Follow the instructions supplied with the control installed WARNING! DO NOT place combustible objects in front of to operate your fi replace: the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. For safety: Avoid placing candles and other heat-sens

Summary of the content on the page No. 11

I. Lighting Instructions (IPI) • For normal use, activate/deactivate your fi replace with the wall switch or remote control. • The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer. • If your fi replace must be deactivated for service or an extended period of time, follow the instructions below. This appliance needs fresh air for safe operation and must be installed so there are p

Summary of the content on the page No. 12

J. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • Turn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly. See Section 14.H. • Clean fi xed glass assembly. See Section 3.A. • Replace the fi xed glass assembly and run continuously on high an additional 12 hours. This cures the materials used to manufacture the fi re- place. NOTICE! Open windows for air circulation during fi replace break-in.

Summary of the content on the page No. 13

Maintenance and Service 3 3 • Carefully set fi xed glass assembly in place on fi replace. Any safety screen or guard removed for servicing must be Hold glass in place with one hand and secure glass replaced prior to operating the fi replace. latches with the other hand. • Reinstall door or decorative front. When properly maintained, your fi replace will give you many years of trouble-free service. We recommend an- nual service by a qualifi ed service technician. Doors, Surrounds, Fronts Fr

Summary of the content on the page No. 14

B. Maintenance Tasks-Qualifi ed Service Burner Ignition and Operation Technician Frequency: Annually The following tasks must be performed by a qualifi ed By: Qualifi ed Service Technician service technician. Tools needed: Protective gloves, vacuum cleaner, whisk Gasket Seal and Glass Assembly Inspection broom, fl ashlight, voltmeter, indexed drill bit set, and a manometer. Frequency: Annually • Verify burner is properly secured and aligned with pilot By: Qualifi ed Service Technician or ignite

Summary of the content on the page No. 15

Installer Guide Getting Started 4 4 A. Typical Appliance System NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Vertical Termination Cap (SECTION 10) Noncombustible roof Storm Collar flashing maintains minimum (SECTION 10) clearance around pipe (SECTION 10) Vent pipe penetrates roof, preferably without affecting roof rafters (SECTION 8) Vent Pip

Summary of the content on the page No. 16

B. Design and Installation Considerations D. Inspect Appliance and Components Heatilator direct vent gas appliances are designed to op- • Carefully remove the appliance and components from erate with all combustion air siphoned from outside of the the packaging. building and all exhaust gases expelled to the outside. No • The vent system components and decorative doors and additional outside air source is required. fronts may be shipped in separate packages. • If packaged separately, the lo

Summary of the content on the page No. 17

Framing and Clearances 5 5 NOTICE: Illustrations refl ect typical installations and are A. Select Appliance Location FOR DESIGN PURPOSES ONLY. Illustrations/diagrams When selecting a location for the appliance it is important are not drawn to scale. Actual installation may vary due to to consider the required clearances to walls (see Figure individual design preference. 5.1). WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access. Due to h

Summary of the content on the page No. 18

C. Clearances NOTICE: Install appliance on hard metal or wood surfaces extending full width and depth. DO NOT install directly on carpeting, vinyl, tile or any combustible material other than wood. WARNING! Risk of Fire! Maintain specifi ed air space clearances to appliance and vent pipe: • Insulation and other materials must be secured to prevent accidental contact. • The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with

Summary of the content on the page No. 19

D. Mantel and Wall Projections Mantel Legs or Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specifi ed. Framing or fi nishing material closer than the minimums listed must be construct- Top of ed entirely of noncombustible materials (i.e., steel studs, Appliance concrete board, etc). Drywall Mantels A B 30 in. minimum Mantel Leg or to ceiling Perpendicular Wall 18 17 16 A 0 in. min. 15 16-3/4 14 16 to perpendicular wall 13 15-1/4 12 14-1/2 B 4

Summary of the content on the page No. 20

Termination Locations 6 6 A. Vent Termination Minimum Clearances AB WARNING 6in. (minimum)upto20in. 18 in. minimum 152 mm/508 mm 457 mm Fire Risk. 20 in. and over 0 in. minimum Maintain vent clearance to combustibles as Gas, Wood or Fuel Oil specifi ed. Termination Cap • DO NOT pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause overheating and fi re. B Minimum DV = 20 in. (508 mm) Horizontal A * BV = 8 ft overhang (


Alternative user manuals
# User manual Category Download
1 Hearth and Home Technologies 3100-I User manual Indoor Fireplace 4
2 Hearth and Home Technologies 6000G-IPI User manual Indoor Fireplace 0
3 Hearth and Home Technologies 6000G-LP User manual Indoor Fireplace 0
4 Hearth and Home Technologies 6000G User manual Indoor Fireplace 0
5 Hearth and Home Technologies 6000GBV User manual Indoor Fireplace 0
6 Hearth and Home Technologies 6000G-IPILP User manual Indoor Fireplace 0
7 Hearth and Home Technologies 6000GBV-IPI User manual Indoor Fireplace 1
8 Hearth and Home Technologies 6000 Series User manual Indoor Fireplace 0
9 Hearth and Home Technologies 6000GCF-IPIL User manual Indoor Fireplace 0
10 Hearth and Home Technologies 6000GCF-IPI User manual Indoor Fireplace 0
11 Hearth and Home Technologies 6000GBV-IPILP User manual Indoor Fireplace 0
12 Hearth and Home Technologies 6000GL-IPI-R User manual Indoor Fireplace 0
13 Hearth and Home Technologies 6000GBV-LP User manual Indoor Fireplace 0
14 Hearth and Home Technologies 6000GL-IPI-S User manual Indoor Fireplace 0
15 Hearth and Home Technologies 6000GL-IPILP-S User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1