CFM Corporation 2467, 2468 user manual

User manual for the device CFM Corporation 2467, 2468

Device: CFM Corporation 2467, 2468
Category: Indoor Fireplace
Manufacturer: CFM Corporation
Size: 2.5 MB
Added : 2/27/2013
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for CFM Corporation 2467, 2468. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with CFM Corporation 2467, 2468.

For your convenience

If looking through the CFM Corporation 2467, 2468 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual CFM Corporation 2467, 2468 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual CFM Corporation 2467, 2468 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
CFM Corporation 2467, 2468 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual CFM Corporation 2467, 2468 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to CFM Corporation 2467, 2468. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

C
N
E
R
G
T
I
INSTALLER / CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
Dutchwest
WARNING!
Natural Vent Gas
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
Heater
EXACTLY, A FIRE OR EXPLOSION
Models: 2467, 2468
MAY RESULT CAUSING PROP-
ERTY DAMAGE, PERSONAL IN-
JURY OR LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service
agency or the gas suppler.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to li

Summary of the content on the page No. 2

Dutchwest Natural Vent Gas Heater Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions ........................................................................

Summary of the content on the page No. 3

Dutchwest Natural Vent Gas Heater Installation & Operating Instructions The Dutchwest Natural Vent Room Heater, Model Nos. 2467 This appliance is approved for bedroom installations in the and 2468, is a vented gas appliance listed to the ANSI standard U.S. and Canada. Z21.88b-2001 and CSA-2.33b-2001 for Vented Room Heaters, This appliance may be installed in an aftermarket* manufac- and CSA 2.17-M91, Gas-Fired Appliances For Use at High Alti- tured (mobile) home, where not prohibited by stat

Summary of the content on the page No. 4

Dutchwest Natural Vent Gas Heater Dutchwest Natural Vent Gas Heater Dimensions See Page 5 for Flue Collar Centerline Dimensions. 6³⁄₄" (172mm) C L Valve Inlet 24¹⁄₂" (622mm) 28³⁄₈" (721mm) Valve C L 4³⁄₈" Inlet (111mm) 12¹⁄₂" 23" (318mm) (584mm) 17" (419mm) Fig. 1 Dutchwest dimensions. 44 30002008

Summary of the content on the page No. 5

Dutchwest Natural Vent Gas Heater Ceiling Clearances Clearance Requirements Minimum Clearances to Combustible Materials 45" (1140mm) Measure side clearances as shown in Figures 2 through 5 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost 72" (1829mm) surface of the sheet metal rear skirt. The Dutchwest heater is approved for installation into an alcove constructed of combustible materials to the dimensions and clearances shown in Figure 5. The same clear

Summary of the content on the page No. 6

Dutchwest Natural Vent Gas Heater Gas Specifications Venting Requirements and Options Max. Min. The Dutchwest must be properly connected to a listed Input Input 4” (100mm) Type B venting system or to an approved Model Fuel Gas Control BTU/h BTU/h Class A masonry or factory-built chimney system. In Canada, a complete relining of Class A chimney 2467 Nat Millivolt 28,000 20,000 systems is required. 2468 Prop Millivolt 28,000 19,000 The Dutchwest Natural Vent stove will accept decora- Weight: Fully

Summary of the content on the page No. 7

Dutchwest Natural Vent Gas Heater Passing Through a Venting Requirements Combustible Wall or Ceiling 36 An approved pass-through device is always required 34 A when a vent passes through a combustible wall or 32 B ceiling. Check with the maker of the vent system for 30 the correct listed devices that are available. A listed 28 pass-through device is required whether or not the 26 installation includes decorative pipe around the Type B 24 venting system. NOTE: It is essential to seal between 22

Summary of the content on the page No. 8

Dutchwest Natural Vent Gas Heater 4. Disassemble the inner shroud from the outer shroud Install the Optional Fan by removing the four screws, two on each side. 1. The fan kit includes a blower assembly and a 5. Place the grommet provided in the manual bag rheostat assembly, connected by a cable. The assembly on the inner shroud. Run the snapstat blower assembly mounts to the bottom rear of the extension assembly leads through the grommet stove, and the rheostat mounts to the left side of the tow

Summary of the content on the page No. 9

Dutchwest Natural Vent Gas Heater Venting System Assembly Snapstat Left Air Duct The venting collar is on the sheet metal draft hood/heat exchanger assembly, over the firebox. Use a B-vent adapter, from the same maker as the rest of the B-vent components, to join the first section of venting to the draft hood. The stove includes a spill switch. Operating this stove ST671 when not connected to a properly installed and main- tained venting system, or tampering with or disconnect- Fig. 12 Install

Summary of the content on the page No. 10

Dutchwest Natural Vent Gas Heater Attach the first section of venting to the B-vent adapter. Connect the Gas Supply Line Depending on the length of the individual venting Check the Rating Plate attached by a steel cable to the sections and the lengths of the decorative pipe, you firebox, to confirm that you have the appropriate firebox may need to slip the decorative pipe over the venting for the type of fuel to be used. The Dutchwest may be sections before attaching upper sections to lower ones

Summary of the content on the page No. 11

TP TPTH TH PILOT ADJ Dutchwest Natural Vent Gas Heater Burner Information The appliance must only use the gas specified on the rating plate, unless converted using a CFM Specialty Home Products Fuel Conversion Kit. Refer to Page 23 for the correct Fuel Conversion Kit for your model. Conversion instructions are provided with each kit and beginning on Page 16 in this manual. ST228 THIS APPLIANCE SHOULD BE CON- Fig. 20 Attach switch wires to valve. NECTED TO THE GAS SUPPLY ONLY BY A QUALIFIED GAS

Summary of the content on the page No. 12

D DU UT TC CH HW WE ES ST T Est. 1974 Dutchwest Natural Vent Gas Heater Install the Stove Front Left Log Insert the handle stub into the hole in the front casting. Right Fasten in place with the 3/8” locking nut provided. (Fig. Log 23) The front attaches to the stove by four steel tabs that engage with corresponding cast ribs onto the sides and bottom of the stove body. Position the front about 3” down from stove top and lift the plate to engage the upper tabs behind the adjacent ribs on the sid

Summary of the content on the page No. 13

Dutchwest Natural Vent Gas Heater Operation Your First Fire Read these instructions carefully and familiarize yourself with the burner controls. Locate the pilot assembly, Figure 25. Follow the lighting instructions on Page 14 exactly. During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within an hour or so, however, you can open a window to provide fresh air CO105c to alleviate the condition. Fig. 26 Correct

Summary of the content on the page No. 14

O 3 2 ON 1 T O Dutchwest Natural Vent Gas Heater Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- instructions. ally. When lighting the pilot follow these instruc- • If you cannot reach your gas supplier, call the tions exactly. Fire Department B. BEFORE LIGHTING smell all aroun

Summary of the content on the page No. 15

Dutchwest Natural Vent Gas Heater Troubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION A. Defective or misaligned Using a match, light [ilot. If pilot lights, turn off pilot and 1. Spark ignitor will electrode at the pilot push the ignitor button again. If pilot will

Summary of the content on the page No. 16

O L L L I I Dutchwest Natural Vent Gas Heater 5. Remove the rear log bracket by loosening the screw Fuel Conversion Instructions and sliding the bracket up. CAUTION: Do not remove the screw completely. It would be very WARNING! This conversion kit shall be installed difficult to replace it. (Fig. 29) by a qualified service agency in accordance with the manufacturer’s instructions and all applicable Loosen Screw Remove Screws codes and requirements of the authority having Rear Log Bracket jurisdi

Summary of the content on the page No. 17

Dutchwest Natural Vent Gas Heater • Remove pilot orifice with allen wrench. (Fig. 32) 1/8" Air Shutter (LP Position) • Install the conversion orifice. • Reinstall pilot hood. Be sure to align hood with index tab. 3/8" Pilot Hood Configuration for Stove with Serial #’s up to #5483 Air Shutter (LP Position) Pilot Configuration for Stoves with Bracket Serial #’s Starting at #5484 ST726 CO105a Fig. 31 Remove pilot hood. Fig. 34 LP air shutter settings. Index Tab Left Burner Leg Allen Wrench Injec

Summary of the content on the page No. 18

Dutchwest Natural Vent Gas Heater Table 2. Injector Orifice Size Matrix Conversion to Natural Gas Input (BTU/h) Air Shutter Kit # Front Part # Rear Part # Minimum Maximum Setting 000-5021 #54 / .055” 20000130 #44 / .086” 30000334 19,000 28,000 Fully Closed Conversion to LP Input (BTU/h) Air Shutter Kit # Front Part # Rear Part # Minimum Maximum Setting 000-5022 #69 / .029” 30000513 #54 / .055” 20000130 21,500 28,000 3/8” Open 1818 30002008

Summary of the content on the page No. 19

D DU UT TC CH HW WE ES ST T Est 1974 . Dutchwest Natural Vent Gas Heater Maintenance Your Dutchwest Gas Heater will provide years of CAUTION service with minimal upkeep. The following procedures will help ensure that your stove continues to function TURN THE PILOT OFF BEFORE PAINTING. properly. ALLOW THE HEATER TO COOL COMPLETELY BEFORE PAINTING. Annual System Inspection Have the entire heater and venting system inspected Cleaning the Glass annually by a qualified gas technician. Replace any wo

Summary of the content on the page No. 20

Dutchwest Natural Vent Gas Heater Inspect the Vent System Annually Have the vent system inspected annually by a quali- fied technician. Shut off the main gas supply before inspecting the system. Both the inner exhaust pipe and the outer combustion supply pipe must be checked to confirm that they are unblocked and in good condition. Check the Gas Flame Regularly To ensure that the stove is operating properly, check ST582 the flames periodically to confirm they match Figure 39. Fig. 37 Release t


Alternative user manuals
# User manual Category Download
1 CFM Corporation Arch Screen Door Kit GAHJ4S0 User manual Indoor Fireplace 0
2 CFM Corporation DVT38IN User manual Indoor Fireplace 0
3 CFM Corporation DVT44IN User manual Indoor Fireplace 0
4 CFM Corporation Arch Screen Door Kit GASS4S0 User manual Indoor Fireplace 0
5 CFM Corporation 2468 User manual Indoor Fireplace 0
6 CFM Corporation A132 User manual Indoor Fireplace 1
7 CFM Corporation EF26FG User manual Indoor Fireplace 0
8 CFM Corporation A125 User manual Indoor Fireplace 0
9 CFM Corporation Arch Screen Door Kit GAHR4S0 User manual Indoor Fireplace 0
10 CFM Corporation EF22 User manual Indoor Fireplace 7
11 CFM Corporation Arch Screen Door Kit GABS4S0 User manual Indoor Fireplace 0
12 CFM Corporation EF26 User manual Indoor Fireplace 0
13 CFM Corporation EF33 User manual Indoor Fireplace 8
14 CFM Corporation EF28 User manual Indoor Fireplace 0
15 CFM Corporation HEF22 User manual Indoor Fireplace 5
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1