Panasonic CU-E21CKE user manual

User manual for the device Panasonic CU-E21CKE

Device: Panasonic CU-E21CKE
Category: Air Conditioner
Manufacturer: Panasonic
Size: 8.88 MB
Added : 7/9/2013
Number of pages: 100
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Panasonic CU-E21CKE. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Panasonic CU-E21CKE.

For your convenience

If looking through the Panasonic CU-E21CKE user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Panasonic CU-E21CKE on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Panasonic CU-E21CKE to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Panasonic CU-E21CKE User manual - Online PDF
Advertisement
« Page 1 of 100 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Panasonic CU-E21CKE but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Panasonic CU-E21CKE. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Order No. MAC0308013C2
Room Air Conditioner
CS-E18CKE CU-E18CKE
CS-E21CKE CU-E21CKE
CONTENTS
Page Page
1 Features 2 10.4. INSTALLATION, TRANSFERRING, SERVICING 59
2 Functions 3 11 Installation Instructions 63
3 ProductSpecifications 6 11.1. Safety Precautions 63
4 Dimensions 10 11.2. INDOOR UNIT 66
5 RefrigerationCycleDiagram 12 11.3. OUTDOOR UNIT 69
6 BlockDiagram 13 12 Servicing Information 72
7 WiringDiagram 14 12.1. Troubleshooting 72
8 OperationDetails 15 12.2. Breakdown Self Diagn

Summary of the content on the page No. 2

15 Replacement Parts List 85 18.2. PRINT PATTERNINDOOR UNIT PRINTED CIRCUIT 16 Exploded View 86 BOARD 99 17 Replacement Parts List 87 18.3. PRINT PATTERNOUTDOOR UNIT PRINTED CIRCUIT 18 Electronic Circuit Diagram 88 BOARD VIEW 100 18.1. REMOTE CONTROL 98 1 Features • Product • Serviceability − Microcomputer-controlled compressor operating − Washable Front Panel frequency − Breakdown Self Diagnosis function − Vertical and Horizontal Airflow Directions − Five modes of operation selection

Summary of the content on the page No. 3

2 Functions Remote Control Illuminable buttons OFF/ON I FAN SPEED Operation OFF / ON Indoor Fan Speed Selection • Low • Medium- MODE • Medium Operation Mode Selection • Medium+ • High • a Automatic Operation • AUTO Automatic Fan Speed • HEAT Heating Operation FAN • COOL Cooling Operation TEMP • DRY Soft Dry Operation Room Temperature Setting • FAN Fan Operation • Increase or decrease set temperature. (16°C to 30°C) TIMER POWERFUL ON Powerful Mode Operation OFF Timer Setting • 24-hour, OFF / ON R

Summary of the content on the page No. 4

Indoor Unit Five Operation Modes Automatic Operation Switch • Press for < 5s to run Automatic Operation. • Automatic, Heating, Cooling, Soft Dry (Used when the remote control cannot be used.) and Fan Operation. • Press continuously for 5s and < 8s to run Forced Cooling Operation. Automatic and 5 Manual Indoor • Press continuously for 8s and < 11s to Fan Speeds run Forced Heating Operation. • Press continuously for 11s and < 16s to Automatic and 5 Manual Vertical change different remote controlli

Summary of the content on the page No. 5

Outdoor Unit Breakdown Self Diagnosis Time Delay Safety Control Function 30 seconds Forced Operation Low Pressure Control (Gas Leakeage Detection) Overload Protection Control Indoor Power Relay Control Total Running Current Control Compressor Overheating Anti-Dew Formation Control Prevention Control Anti Freezing Control IPM (Power Transistor) Overheating Protection Control Anti-Cold Draft Control Low Operation Frequency Protection Control Hot Start Mininum Operation Frequency Intake Air Tempera

Summary of the content on the page No. 6

3 ProductSpecifications Unit CS-E18CKE CU-E18CKE Cooling Capacity kW 5.30 (0.90 - 6.00) kcal/h 4,560 (770 - 5,160) BTU/h 18,100 (3,070 - 20,500) Heating Capacity kW 6.60 (0.90 - 8.00) kcal/h 5,680 (770 - 6,880) BTU/h 22,500 (3,070 - 27,300) Moisture Removal l/h 2.9 Pint/h (6.1) Power Source Phase Single V 230 Cycle 50 Airflow Method OUTLET SIDE VIEW TOP VIEW INTAKE 3 Air Volume Indoor Air (Lo) m /min (cfm) Cooling; 12.5 (440) — Heating; 13.9 (490) 3 Indoor Air (Me) m /min (cfm) Cooling; 14.0 (49

Summary of the content on the page No. 7

Unit CS-E18CKE CU-E18CKE Pipe Size inch G (gas side) ; 1/2” G (gas side) ; 1/2” (Flare piping) inch L (liquid side) ; 1/4” L (liquid side) ; 1/4” Drain Inner diameter mm 12 — Hose Length m 0.65 — Power Cord Length 2.1 m — 2 Number of core-wire 3 core wires × 1.5 mm — Dimensions Height inch (mm) 10 - 13/16 (275) 29 - 17/32 (750) Width inch (mm) 39 - 9/32 (998) 34 - 7/16 (875) Depth inch (mm) 8 - 9/32 (210) 13 - 19/32 (345) Net Weight lb (kg) 24 (11) 108 (49) Compressor Type — Involute scroll Moto

Summary of the content on the page No. 8

Unit CS-E21CKE CU-E21CKE Cooling Capacity kW 6.30 (0.90 - 7.10) kcal/h 5,420 (770 - 6,110) BTU/h 21,500 (3,070 - 24,200) Heating Capacity kW 7.20 (0.90 - 8.50) kcal/h 6,190 (770 - 7,310) BTU/h 24,600 (3,070 - 29,000) Moisture Removal l/h 3.5 Pint/h (7.4) Power Source Phase Single V 230 Cycle 50 Airflow Method OUTLET SIDE VIEW TOP VIEW INTAKE 3 Air Volume Indoor Air (Lo) m /min (cfm) Cooling; 12.6 (440) — Heating; 14.0 (490) 3 Indoor Air (Me) m /min (cfm) Cooling; 14.5 (510) — Heating; 15.8 (560)

Summary of the content on the page No. 9

Unit CS-E21CKE CU-E21CKE Drain Inner diameter mm 12 — Hose Length m 0.65 — Power Cord Length 2.1 m — 2 Number of core-wire 3 core wires × 1.5 mm — Dimensions Height inch (mm) 10 - 13/16 (275) 29 - 17/32 (750) Width inch (mm) 39 - 9/32 (998) 34 - 7/16 (875) Depth inch (mm) 8 - 9/32 (210) 13 - 19/32 (345) Net Weight lb (kg) 24 (11) 112 (51) Compressor Type — Involute scroll Motor Type — Brushless (4-pole) Rated Output W — 900 Air Circulation Type Cross-flow Fan Propeller Fan Material ASHT-18 P.P M

Summary of the content on the page No. 10

4 Dimensions 10

Summary of the content on the page No. 11

11

Summary of the content on the page No. 12

5 RefrigerationCycleDiagram 12

Summary of the content on the page No. 13

6 BlockDiagram 13

Summary of the content on the page No. 14

7 WiringDiagram 14

Summary of the content on the page No. 15

8 OperationDetails 8.1. BASICFUNCTION Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes, automatically adjusts output power for maximum comfort always. In order to achieve the suitable operating mode, the microcomputer maintains the set temperature by measuring the temperature of the environment and performing temperature shifting. The compressor at outdoor unit is operating following the frequency instructed by the microcomputer

Summary of the content on the page No. 16

Table (b): Outdoor Air Temperature Shifting Mode: Outdoor Temperature, X (°C): Temperature Shift (°C) Manual Operation Auto Operation Cooling/Soft Dry 38 X 1.50 2.00 30 X 38 1.25 1.25 23 X 30 1.25 1.25 X 23 1.75 1.75 Heating 21 X -2.25 -1.50 17 X 21 -1.75 -1.00 13 X 17 -0.75 0.00 9 X 13 0.25 0.25 5 X 9 1.25 1.00 1 X 5 0.75 1.00 -3 X 1 1.50 1.00 X -3 1.50 1.00 Table (c): Powerful Mode Shifting Mode: Period, X (min): Temperature Shift (°C) Cooling X 20 -2.0 X 20 0.0 Soft Dry X 20 -1.0 X 20 0.0 Hea

Summary of the content on the page No. 17

8.1.2. CompressorOperationFrequency Intake Air Temperature - Internal Setting Temperature (°C) Freq. H Zone Cooling & Soft Dry Heating Cooling Soft Dry Heating Remark 1 -2.0 1.5 1 1 1 2 -1.5 1.0 1 1 1 3 -1.0 0.5 14 8 11 4 -0.5 0.0 20 8 15 5 0.0 -0.5 27 8 22 6 0.5 -1.0 35 11 27 7 1.0 -1.5 43 11 36 8 1.5 -2.0 46 11 39 Fc, Fh 9 2.0 -2.5 46 11 39 Fc, Fh 10 2.5 -3.0 46 11 39 Fc, Fh 11 Nil -3.5 Nil Nil 39 Fh 12 Nil -4.0 Nil Nil 39 Fh Operating Frequency Calculation Formula: CompHz = Freq. A × Freq. H

Summary of the content on the page No. 18

8.1.4. SoftDryOperation 8.1.4.1. Thermostatcontrol • Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -2.5°C. • Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF point. 8.1.5. HeatingOperation 8.1.5.1. Thermostatcontrol • Compressor is OFF when Intake Air Temperature - Internal Setting > +1.5°C. • Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Settin

Summary of the content on the page No. 19

Values of T1, T2, and T3 depend on remote control setting temperature, as shown in below table. After the adjustment of T1, T2 and T3 values, the operation mode for that particular environment and remote control setting is judged and performed, based on the above operation mode chart, every 30 minutes. Remote Control Setting Temperature (°C) T1 T2 T3 16 ~ 18 +10 +8 -5 19 ~ 22 +8 +7 -7 23 ~ 26 +7 +6 -7 27 ~ 30 +6 +5 -8 There is a temperature shifting on T1, T2, and T3 if the operation mode judged

Summary of the content on the page No. 20

B. Indoor Fan Control i. Indoor fan control operation outline 1. Cooling / Dry 2. Heating 20


Alternative user manuals
# User manual Category Download
1 Panasonic CS-1873KR User manual Air Conditioner 243
2 Panasonic CS-A12CKPG User manual Air Conditioner 72
3 Panasonic CS-A12CKP User manual Air Conditioner 98
4 Panasonic AC Robot 2006/2007 User manual Air Conditioner 45
5 Panasonic 2008 User manual Air Conditioner 83
6 Panasonic CS-A18CTP User manual Air Conditioner 28
7 Panasonic AW-PS505 User manual Air Conditioner 6
8 Panasonic CS-A12CTP User manual Air Conditioner 31
9 Panasonic CS-A24CTP User manual Air Conditioner 36
10 Panasonic CS-A24CKPG User manual Air Conditioner 4
11 Panasonic CS-A7CKP User manual Air Conditioner 207
12 Panasonic CS-A9CKP User manual Air Conditioner 45
13 Panasonic CS-A9CKPG User manual Air Conditioner 9
14 Panasonic CS-C12CKP User manual Air Conditioner 19
15 Panasonic CS-C24BKP User manual Air Conditioner 33
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21