Summary of the content on the page No. 1
C
N
E
R
G
T
I
Natural Vent Insert
Models: RHE25
RHE32
RHE42
Installation Instructions & Homeowner's Manual
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
DO NOT STORE
• Do not try to light any appliance.
OR USE GASOLINE OR OTHER
• Do not touch any electric switch
FLAMMABLE VAPOURS AND LIQUIDS
• Do not use any phone in your build
Summary of the content on the page No. 2
Vermont Castings, Majestic Products RHE Natural Vent Insert Table of Contents Please read the Installation & Operating Instructions before using this appliance. Thank you and congratulations on your purchase of a Majestic fireplace insert. IMPORTANT - Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the manufacturers' warranty. Installation Instructions General Information ..........
Summary of the content on the page No. 3
Vermont Castings, Majestic Products RHE Natural Vent Insert Installation Instructions This gas appliance should be installed by a qualified installer IMPORTANT: in accordance with local building codes and with current CSA- PLEASE REVIEW THE FOLLOWING CAREFULLY B149.1 Installation codes for Gas Burning Appliances and Equipment. Remove any plastic from trim parts before turning the For U.S.A Installations follow local codes and/or the current fireplace ON. National Fuel Gas Code. ANSI Z223.1. It i
Summary of the content on the page No. 4
Vermont Castings, Majestic Products RHE Natural Vent Insert Fireplace Dimensions F B D E A G H Maintain 1" Zero Clearance Kit (25mm) Clearance C to B-Vent Minimum Fireplace M Insert Opening P L O U K Q V T 1" (25mm) N S Air Inlet Channel R Gas Inlet Knock-out Q - Fireplace Opening Height T - Firebox Width at Insert Depth(s) 1 = SS or SSD Trim R - Fireplace Opening Width U - Firebox Depth at Insert Back Height (V) 2 = SL or SLD Trim S - Depth of Insert V - Insert Back Height 3 = SXL Trim 4 = BSL
Summary of the content on the page No. 5
Vermont Castings, Majestic Products RHE Natural Vent Insert The use of wallpaper adjacent to this Mantels fireplace is not recommended, as the high heat given off by this fireplace may When the insert is being installed into a woodburning adversely effect the binders in the adhe- fireplace the minimum the mantel can be above the sive used to apply the wallpaper. fireplace is governed by local building codes applicable to woodburning fireplaces. Consult local authorities having jurisdiction for
Summary of the content on the page No. 6
Vermont Castings, Majestic Products RHE Natural Vent Insert Zero Clearance Applications The installation of your Majestic Fireplace must conform with local codes, or in the An alternate air supply is recommended absence of local codes, with National Fuel Gas with this component. Code, ANSI Z223.1 latest edition, or CSA- B149.1 Installation Code. (EXCEPTION: Do For installations other than in existing woodburning not derate this appliance for elevations up to fireplaces such as new constructi
Summary of the content on the page No. 7
L I P LO THTP TP TH PILOT Vermont Castings, Majestic Products RHE Natural Vent Insert Installation of Remote Switch 1/2" Gas Supply 1/2" x 3/8" Reducer for RN/RP Gas Valves 3/8" x 3/8" Shut Off 1. Thread wire through gas inlet opening on the right Valve side of fireplace. Do not cut wire or insulation on 3/8" Union metal edges. 2. Slide switch assembly from the back, between subframe and trim, then fasten the screw. (Fig. 6) 3. For left side installation reverse switch position in 3/8" Nipple FP
Summary of the content on the page No. 8
Vermont Castings, Majestic Products RHE Natural Vent Insert Venting and Installation Installer must attach red warning plate with screws supplied with the gas fire- place insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed. WARNING This fireplace has been converted for use with FP1218a gas only and cannot be used for burning wood or solid fuels unless all original parts have been Fig. 8b ON/OFF switch wiring. replaced and the fireplace has been
Summary of the content on the page No. 9
Vermont Castings, Majestic Products RHE Natural Vent Insert 4. Flue damper must be fully blocked in the open Chimney Liner Damper Damper position or removed for installation. Chimney 5. The chimney must be clean and in good working Liner Flue order and constructed of noncombustible materials. Collar Plate Clamp Screw Clamp 6. Make sure that all chimney cleanouts fit properly so air cannot leak into the chimney. 7. Glass door, screen kits and log grate may be removed for installation of insert in
Summary of the content on the page No. 10
Vermont Castings, Majestic Products RHE Natural Vent Insert Operation of this fireplace when not connected to a properly installed and maintained venting system or tampering Stud with the vent safety shutoff system can result in carbon monoxide (CO) Thermal Sensor is Fan is installed attached to burner poisoning and possibly death. at the back of base the air intake box Fan Kit Stud Valve 115 Volt, 60 Hz. 56W The fan kit includes the following: fan, temperature Fan Speed Control/Junction Box s
Summary of the content on the page No. 11
Vermont Castings, Majestic Products RHE Natural Vent Insert Operating Instructions General Glass Information Before remounting glass frame, brass trim must be installed. Refer to instruc- Only ceramic glass approved for use in Majestic tions in "Frame Mounting" section. fireplaces may be used for replacement on this fireplace. 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass. 3. Under no circumstances should this fireplace be
Summary of the content on the page No. 12
I HI L Vermont Castings, Majestic Products RHE Natural Vent Insert Flame Adjustment (RN/RP Models) JR5 JR6 JR4 For fireplaces equipped with HI/LO valve, flame adjust- ment is accomplished by rotating the HI/LO adjustment knob located near the center of the gas control. JR3 JR2 (Figs. 20 & 21) Turn counterclockwise Turn clockwise to decrease to increase flame height flame height Burner Lava Rock KR1 LG279 Placement Fig. 20 Flame adjustment knob for Honeywell Valve. Fig. 17 RHE25 log and lava ro
Summary of the content on the page No. 13
Vermont Castings, Majestic Products RHE Natural Vent Insert First Firing Upon completing the gas line connection, a small amount of air will be in the lines. When first lighting unit with pilot light, it will take a few minutes to purge themselves of air. Once the purging is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lightings of the heater will not require such purging. LG282 When lit for the first time, the appliance will emit a Fig
Summary of the content on the page No. 14
O 3 2 ON 1 T O Vermont Castings, Majestic Products RHE Natural Vent Insert Lighting And Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- instructions. ally. When lighting the pilot follow these instruc- • If you cannot reach your gas supplier, call tions exactly. the Fire Department B. BEFOR
Summary of the content on the page No. 15
Vermont Castings, Majestic Products RHE Natural Vent Insert Troubleshooting the Gas Control System SIT NOVA 820 Millivolt Valve NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. WARNING: Before doing any gas control service work, remove glass front. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1.Spark ignitor will not light A. Defective or misaligned Using a match, light pilot. If pilot lights, turn off electrode at pilot. pilot and push
Summary of the content on the page No. 16
Vermont Castings, Majestic Products RHE Natural Vent Insert Troubleshooting the Gas Control System Eurosit 630 Gas Valve NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: Before doing any gas control service work, remove glass front. Symptom Possible Causes Corrective Action 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot. If pilot lights, turn off pilot and electrode at pilot. push the red
Summary of the content on the page No. 17
Vermont Castings, Majestic Products RHE Natural Vent Insert Troubleshooting the Gas Control System Honeywell Millivolt Valve START CHECK Gas Supply On NO Supply Line Hooked Up Shutoff Valve Open YES Lockout Has Engaged. Wait 60 Seconds And Try Again. For Spark At Electrode While Pilot Lights With Depressing Piezo 1/8" Gap To NO Piezo Ignitor Pilot Hood Needed. All Wiring Connections Replace Piezo Ignitor YES For Air In The Lines Thermopile Needs A Minimum 325mv. Adjust Pilot Flame Height.
Summary of the content on the page No. 18
Vermont Castings, Majestic Products RHE Natural Vent Insert Maintenance Burner and Burner Compartment Visually inspect pilot. Brush or blow away any dust or lint accumulation. If pilot orifice is plugged, disassembly It is important to keep the burner and the burner may be required to remove any foreign material from compartment clean. At least once per year the logs and the orifice or tubing. lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove To
Summary of the content on the page No. 19
O LO L PILOT Vermont Castings, Majestic Products RHE Natural Vent Insert 12 19 5 10 a/b 18 31 30 4a/b 16 11 a/b 14 20 24 a/b 8a/b 27 9 a/b 6/7 a/b 32 28 13 18 17 29 15 22a/b 35 25 34 3 2 36 26 OFF 38 40 21 39a/b 23 a/b 33 41a/b 44 42a/b OFF ¥ 43 45 1d 1d 1d 1f 1f 1f 1e 1e 1e 1b 1c 1c 1b 1c 1b 1a 1a 1a 0836 Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. RHE25/32/42
Summary of the content on the page No. 20
Vermont Castings, Majestic Products RHE Natural Vent Insert RHE25/32/42 Series (continued) Ref. Description RHE25 RHE32 RHE42 1. Log Set Complete 10000191 57896 10000206 1a. Log Ember Front KR1 KR1 SR1 1b. Log Front Left JR2 KR2 SR 1c. Log Front Right JR3 KR3 SR3 1d. Log Rear JR4 KR4 SR4 1e. Log Top Left JR5 KR5 SR5 1f. Log Top Right JR6 KR6 SR6 2. Lava Rock (Package) 10001454 10001454 10001454 3. Burner Lava Rock (Package) 57897 57897 57897 4a. Burner Complete with tiles Nat. 10000192 57903 100