Vermont Casting DVT44 user manual

User manual for the device Vermont Casting DVT44

Device: Vermont Casting DVT44
Category: Indoor Fireplace
Manufacturer: Vermont Casting
Size: 11.49 MB
Added : 8/20/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Vermont Casting DVT44. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Vermont Casting DVT44.

For your convenience

If looking through the Vermont Casting DVT44 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Vermont Casting DVT44 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Vermont Casting DVT44 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Vermont Casting DVT44 User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Vermont Casting DVT44 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Vermont Casting DVT44. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

C
N
E
R
G
T
I
INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
Chateau™
USING APPLIANCE
WARNING!
Direct Vent Gas
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
Fireplace
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING
Model: DVT38, DVT44
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
• Do not try

Summary of the content on the page No. 2

Chateau™ Table of Contents Please read the installation & operating instructions before using this appliance. Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation & Important Curing/Burning Instructions .........................................................3 Oper

Summary of the content on the page No. 3

Chateau™ Installation & Operating Instructions This gas fireplace must be installed by a qualified installer, 12. This fireplace requires adequate ventilation and preferably NFI or WETT (Canada) certified, in accordance combustion air to operate properly. with local building codes and with current CSA-B149.1 13. This fireplace must not be connected to a chimney flue Installation codes for Gas Burning Appliances and serving a separate solid fuel burning fireplace. Equipment. For USA Installation

Summary of the content on the page No. 4

Chateau™ Fireplace Dimensions - DVT38 11 ���" Rough (298mm) 17" (432mm) Opening Depth 8���" Dia. 54" (1372 mm) (213 mm) 3" (76 mm) 11" Dia. (279 mm) 25���" (648 mm) 28���" (724 mm) Rough Opening Width ����� " 3/4" (19 mm) (1114 mm) Rough Opening Height 1���" No combustible 49���" (41 mm) (1257 mm) material in this area 33���" (848 mm) 12����” �����" (876 mm) (319 mm) 29���" (746 mm) 17 ����” 1/2" (13 mm) (440 mm) 7�����” 37���" (962 mm) 2���" 7����” (60 mm) (195 mm) (186 mm) No drywall in this

Summary of the content on the page No. 5

Chateau™ Combustible Locating Your Fireplace Framing and Fin- ish Wall Above V Standoffs May use combus- W tible facing mate- E A B rial in this area Y X Standoff X Y C Z D Y B A B C D E F Noncombustible Fin- ish Material LU584-1 (Such as Dura Rock) Fireplace Front Top of Sheet Fig. 3 Locate gas fireplace. LU584-1 CFM146c Metal Locating unit A) Flat on wall B) Cross corner C) **Island 2/4/99 djt Mantel Chart D) *Room divider E) *Flat on wall corner F) Chase installation Mantel Shelf

Summary of the content on the page No. 6

Chateau™ Hearth A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible hearth which projects out 12” (305 mm) or more from the front of the fireplace. The hearth cannot exceed 1 ¹⁄₂” (38mm) in height from bottom of fireplace for ease of door accessibility. (Fig. 5) Cold climate installation recommendation: When installing this unit against a non- insulated exterior wall or chase, it is mandatory the outer walls be insulated to conform to applic

Summary of the content on the page No. 7

Chateau™ Gas Line Installation Gas Specifications Max. Min. When purging gas line the front glass must Gas Input Input be removed. Model Fuel Control BTU/hr BTU/hr DVT38IN Natural Gas American Flame 46,000 32,000 A gas shut off valve must be installed on DVT38IP Propane AF-4034 46,000 36,000 the gas pipe line going into the appliance DVT44IN Natural Gas with 60,000 37,000 within easy access. Refer to local codes. DVT44IP Propane 7.5V DC Hi/Lo 60,000 45,000 The gas pipeline can b

Summary of the content on the page No. 8

Chateau™ 6. Remove pilot assembly from burner assembly by Electrical Junction Box removing two (2) screws. The fireplace, when installed, must be elec- 7. Carefully slide the burner assembly to the left out of trically connected and grounded in accord- the way, taking care not to bend or break the pilot ance with local codes or, in the absence tubes or wiring. of local codes, with the current CSA C22.1 8. Remove 13 screws around the perimeter holding Canadian Electrical Code or the national

Summary of the content on the page No. 9

PO WER IPI Chateau™ NOTE: If you need to test the inlet pressure and/or Learn Button manifold pressure, there are two (2) test ports available along the right side front edge between the firebox side and outer casing. The upper test port is inlet pressure. Junction Box The lower test port is manifold pressure. CAUTION: Turn off the gas supply before S I Continous Pilot Off/On Remote/Off ADJ. removing test port plug. 23. Using a 7/16” nut driver, remove the threaded plug from the test port.

Summary of the content on the page No. 10

Chateau™ White or Green To Pilot Ignitor Green or White White or Orange Orange or White To Pilot Flame Sensor DC Motor Pilot Main Module AF-4000 Learn Main Optional Remote Button Battery Back-Up Pack Power Orange Black Remote/Off Red Module Red Brown Switch Black Continuous Pilot ON/OFF Switch Pulse/Continuous Extension Button Wire Harness Black Gnd Brown (SWI) (Leave Brown Disconnected) (SWI) Red Black AC Adaptor FP1795 Optional Extension Harness Fig. 11 DVT38/44 wiring diagram. FP1795 Cha

Summary of the content on the page No. 11

V V �������� Chateau™ General Venting Information - Termination Location INSIDE CORNER DETAIL G V N H N A D E B C B ����� ����� L V B V ������ ������ V ����� �������� G ������ F V V B M V G B X B J I X V K V A A VENT TERMINATION X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED V CFM145a 1 2 Canadian Installations US Installations A = Clearance above grade, veranda, porch, 12” (30 cm) 12” (30 cm) CFM145a DV Termin Location deck, or balcony 5/01/01 Rev. 12/05/01 B = Clearance to wi

Summary of the content on the page No. 12

Chateau™ Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner D C C F = Combustible G = 6" (152 mm) Combustible V G 6" (152 mm) Noncombustible V E 2" (51 mm) Noncombustible O V F 2" (51 mm) Balcony - Balcony - with no side wall with perpendicular side wall E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4 m) Min. M No. M of Caps

Summary of the content on the page No. 13

Chateau™ General Information Pipe Section Assembling Vent Pipes Pipe Rim SK8 Venting Pipes Hem Canadian Installations: Lance The venting system must be installed in accordance Pipe with the current CSA-B149 .1 installation code. Rim USA Installations: The venting system must conform with local codes and/ or the current National Fuel Gas code ANSI Z223.1/ NFPA 54. Only venting components manufactured by CFM Cor- poration can be used in Direct Vent systems. NOTE: The joints of the inner pip

Summary of the content on the page No. 14

Chateau™ Minimum clearance between vent pipes �� �� and combustible materials is 3 ¹⁄₂” (89 mm) �� on top, 2 ¹⁄₂” (64 mm) on both sides and 1 ¹⁄₂” �� (38 mm) on the bottom. �� �� When the vent termination exits through foundations �� less than 20” (508 mm) below siding outcrop, the vent �� pipe must be flush with the siding. �� �� It is always best to locate the fireplace in such a way �� that minimizes the number of offsets and horizontal �� vent length of vent pipe from the flue collar of

Summary of the content on the page No. 15

Chateau™ • The maximum number of 45° elbows permitted per Sidewall Installation side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run. (Fig. STEP 1 18) Locate vent opening on the wall. It may be necessary • For each 45° elbow installed in the horizontal run, to first position the fireplace and measure to obtain hole the length of the horizontal run MUST be reduced by location. Depending on whether the wall is combustible 18” (45 cm). This

Summary of the content on the page No. 16

Chateau™ STEP 3 X Slide the zero clearance sleeve through the wall and install the firestop on the inside surface of the wall. Secure with four (4) #8 sheet metal screws. STEP 4 Place fireplace into position. (Fig. 22) Measure the ver- tical height (X) required from the base of the flue collars to the center of the wall opening. NOTE: If using the SK8DVSK Kit, the vertical section of pipe is telescopic and could provide adjustment from 24” up to 40” (610 mm to 1016 mm). FP1241a Fig. 23 Horiz

Summary of the content on the page No. 17

Chateau™ 12' DVT44 - Natural or LP (3.7m) Use 6 ���" or Greater DVT38 - Natural or LP 'X' Use 5 ���" Fresh Air Restrictor Plate X Setting 30’ to 40’ #1 20’ to 29’ #2 12’ to 19’ #3 FP1409 FP1243a Fig. 26 Restrictor plate use in straight up installation. Fig. 25 Secure termination to wall. For vertical venting configurations that include a FP1409 restrictor plate minimum vertical rise of 12’ (3.7 m) and a maximum Vertical Through-the-Roof straight up installation horizontal offset of 10’

Summary of the content on the page No. 18

Chateau™ Max. 8' (2.4m) 4 Max. 20' (6 m) Max. Height 40' (12 m) Min. Height 1 + 2 + 3 + 4 = 270° 20' (6 m) 3 2 1 Pipe Straps Every 3’ (914mm) Minimum 2’ (610mm) Before Any Elbow FP1244a Fig. 28 Support straps for horizontal runs. FP1245a • Up to two (2) 30° or 45° elbows may be used within FP1245a through the roof Fig. 29 Typical offset application. the horizontal run. For each 30° or 45° elbow used 90 & 45 degree on the horizontal level the maximum horizontal FP1244a through the roof

Summary of the content on the page No. 19

Chateau™ Support Structure Attic Installation Elbow Strap Nails (4) Firestop Spacer Elbow Strap (must be tight) Joist Ceiling Hole Framing Angled Strap Ceiling Installation Angled Firestop Chimney Support Strap (must be tight) Joist FP270/271 FP270/271 CR Series Fig. 32 Attach straps to a structural framing member. 2/19/99 djt Firestop Spacer Nails (4) Min. FP593 2' (610mm) Fig. 30 Installing firestop spacer. FP593 SR/C Attic Insulation 11/20/97 Shield Nails (4 Re- quired) CFM190 Attic Jo

Summary of the content on the page No. 20

Chateau™ Chimney Components Component Description Model Number Horizontal Starter Kit Contains 24”-40” telescopic pipe* for minimum vertical SK8DVSK rise from collar pipe, 90° elbow, horizontal through-wall starter pipe, zero clearance sleeve, metal adhesive tape, stove cement tube, sidewall termination and firestop. SK8 Chimney Sections Pipe used to build 8” (SK8) flue systems. SK81 (1’ Long) SK818 (1Z\x’ Long) SK83 (3’ Long) SK84 (4’ Long)


Alternative user manuals
# User manual Category Download
1 Vermont Casting 2080 User manual Indoor Fireplace 2
2 Vermont Casting 2170 User manual Indoor Fireplace 0
3 Vermont Casting 2160 User manual Indoor Fireplace 0
4 Vermont Casting 2547CE User manual Indoor Fireplace 1
5 Vermont Casting 3031 User manual Indoor Fireplace 0
6 Vermont Casting 20DVT User manual Indoor Fireplace 1
7 Vermont Casting 3032 User manual Indoor Fireplace 0
8 Vermont Casting 2465 User manual Indoor Fireplace 0
9 Vermont Casting 2466 User manual Indoor Fireplace 0
10 Vermont Casting 3033 User manual Indoor Fireplace 0
11 Vermont Casting 3030 User manual Indoor Fireplace 0
12 Vermont Casting 3225 User manual Indoor Fireplace 0
13 Vermont Casting 3232 User manual Indoor Fireplace 0
14 Vermont Casting 3350 User manual Indoor Fireplace 0
15 Vermont Casting 3360 User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1