Vanguard Heating VSGF28PTC user manual

User manual for the device Vanguard Heating VSGF28PTC

Device: Vanguard Heating VSGF28PTC
Category: Indoor Fireplace
Manufacturer: Vanguard Heating
Size: 1.18 MB
Added : 4/14/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Vanguard Heating VSGF28PTC. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Vanguard Heating VSGF28PTC.

For your convenience

If looking through the Vanguard Heating VSGF28PTC user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Vanguard Heating VSGF28PTC on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Vanguard Heating VSGF28PTC to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Vanguard Heating VSGF28PTC User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Vanguard Heating VSGF28PTC but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Vanguard Heating VSGF28PTC. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
UNVENTED (VENT-FREE)
PROPANE/LP GAS FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
¢¢¢¢¢¢QQQQQQ
Variable Manually-
QQQQQQ¢¢¢¢¢¢
Controlled Model
¢¢¢¢¢¢QQQQQQ
VSGF28PVA
QQQQQQ¢¢¢¢¢¢
Thermostatically-
QQQQQQ¢¢¢¢¢¢
Controlled Model
QQQQQQ¢¢¢¢¢¢
VSGF28PTC Shown with
QQQQQQ¢¢¢¢¢¢
optional cabinet
with Split Oak Logs
QQQQQQQQQQ¢¢¢¢¢¢¢¢¢¢ QQQQQQ¢¢¢¢¢¢
mantel, hearth
QQQQQQQQQQ¢¢¢¢¢¢¢¢¢¢ ¢¢¢¢¢¢QQQQQQ
base, and trim
¢¢¢¢¢¢¢¢

Summary of the content on the page No. 2

® UNVENTED PROPANE/LP GAS FIREPLACE 4. This fireplace shall not be installed in SAFETY Due to high temperatures, the a bedroom or bathroom. appliance should be located out INFORMATION 5. Do not use this fireplace as a wood- of traffic and away from furniture burning fireplace. Use only the logs and draperies. WARNINGS provided with the fireplace. 6. Do not add extra logs or ornaments IMPORTANT: Read this owner’s Do not place clothing or other such as pine cones, vermiculite, or rock manual care

Summary of the content on the page No. 3

OWNER’S MANUAL SAFETY LOCAL CODES Install and use fireplace with care. Follow all INFORMATION local codes. In the absence of local codes, use Continued the latest edition of The National Fuel Gas 16. Operating fireplace above elevations of Code ANSI Z223.1/NFPA 54*. 4,500 feet could cause pilot outage. *Available from: 17. To prevent performance problems, do not use propane/LP fuel tanks of less American National Standards Institute, Inc. 1430 Broadway than 100 lbs. capacity. New York, NY 10018

Summary of the content on the page No. 4

® UNVENTED PROPANE/LP GAS FIREPLACE Unusually tight construction is de- PRODUCT AIR FOR fined as construction where: FEATURES COMBUSTION AND a. walls and ceilings exposed to the outside atmosphere have a con- OPERATION VENTILATION tinuous water vapor retarder with This vent-free fireplace is clean burning. It -11 a rating of one perm (6 x 10 kg WARNING: This heater shall requires no outside venting. There is no heat 2 per pa-sec-m ) or less with open- not be installed in a confined space loss

Summary of the content on the page No. 5

OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = _______________

Summary of the content on the page No. 6

® UNVENTED PROPANE/LP GAS FIREPLACE AIR FOR 12" COMBUSTION AND VENTILATION Ventilation Ventilation Grills Grills Continued Into Adjoining Room, Into Adjoining Or Option 2 Room, VENTILATION AIR Remove Option 1 Door into Adjoining Ventilation Air From Inside Room, Building QQQQ¢¢¢¢ Option 3 This fresh air would come from an adjoining ¢¢¢¢QQQQ unconfined space. When ventilating to an adjoining unconfined space, you must pro- 12" ¢¢¢¢QQQQ vide two permanent openings: one within 12" of

Summary of the content on the page No. 7

OWNER’S MANUAL ELECTRICAL HOOKUP INSTALLATION CAUTION: This fireplace cre- (Model VSGF28PTC or ates warm air currents. These cur- VSGF28PVA with GA3750 or NOTICE: This heater is intended rents move heat to wall surfaces GA3650T Series Blower) for use as supplemental heat. next to fireplace. Installing fire- Use this heater along with your place next to vinyl or cloth wall This fireplace has a blower assembly with an primary heating system. Do not coverings or operating heater electrical cord. T

Summary of the content on the page No. 8

® UNVENTED PROPANE/LP GAS FIREPLACE CONVENTIONAL FIREPLACE INSTALLATION Trim INSTALLATION Continued Hanging Conventional installation of this fireplace Screws ASSEMBLING AND involves installing fireplace along with the ATTACHING OPTIONAL corner or cabinet mantel with hearth base Hanging BRASS TRIM accessories against a wall in your home (see Notches Accessories, page 22 and 23). Follow the (Included with Mantel on Trim instructions below to install the fireplace in Accessory) this manner. IMPORT

Summary of the content on the page No. 9

OWNER’S MANUAL 10. Carefully insert fireplace into cabinet BUILT-IN FIREPLACE INSTALLATION mantel (Figure 12). Be careful not to INSTALLATION Continued scratch or damage hearth base, cabinet Built-in installation of this fireplace involves mantel, or any laminate trim on hearth 4. Place hearth base accessory against installing fireplace into a framed-in enclo- base. Remove protective material from wall at installation location. Cut an ac- sure. This makes the front of fireplace flush top of hear

Summary of the content on the page No. 10

® UNVENTED PROPANE/LP GAS FIREPLACE Mantel Clearances for Built-In Installation Items Needed INSTALLATION Installation Before installing fireplace, make sure you Continued have the items listed below. If placing mantel above built-in fireplace, 4. Carefully set fireplace in front of rough you must meet minimum clearance between • external regulator (supplied by installer) opening with back of fireplace inside mantel shelf and top of fireplace opening. • piping (check local codes) wall opening. •

Summary of the content on the page No. 11

OWNER’S MANUAL CONNECTING FIREPLACE INSTALLATION NOTICE: Most building codes do TO GAS SUPPLY not permit concealed gas con- Continued nections. A flexible gas line is Installation Items Needed Installation must include an equipment provided to allow accessibility shutoff valve, union, and plugged 1/8" NPT • 5/16" hex socket wrench or nut-driver from the fireplace (see Figure 20). tap. Locate NPT tap within reach for test The flexible gas supply line con- • Phillips screwdriver gauge hook up. NP

Summary of the content on the page No. 12

® UNVENTED PROPANE/LP GAS FIREPLACE Test Pressures Equal To or Less Than Pressure Testing Fireplace Gas INSTALLATION 1/2 PSIG (3.5 kPa) Connections Continued 1. Close equipment shutoff valve (see Fig- 1. Open equipment shutoff valve (see Fig- CHECKING GAS ure 21). ure 21). CONNECTIONS 2. Pressurize supply piping system by ei- 2. Open propane/LP supply tank valve. ther using compressed air or opening 3. Make sure control knob of fireplace is propane/LP supply tank valve. WARNING: Test all gas pi

Summary of the content on the page No. 13

OWNER’S MANUAL Crossover INSTALLATION Log (#4) Front Log (#1) Continued Hole Cutout Notch INSTALLING LOGS Peg WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with Grate this heater may result in property Prongs damage or personal injury. Metal Grate Bar CAUTION: Do not remove the Figure 23 - Installing Front Log (#1) metal data plates attached to the heater base assembly. The data plates contain important warranty Midd

Summary of the content on the page No. 14

® UNVENTED PROPANE/LP GAS FIREPLACE 7. Keep control knob pressed in for 30 LIGHTING OPERATING seconds after lighting pilot. After 30 INSTRUCTIONS FIREPLACE seconds, release control knob. Note: If pilot goes out, repeat steps WARNING: You must operate Thermostat-Controlled Models 3 through 7. This fireplace has a this fireplace with the fireplace safety interlock system. Wait one (1) screen in place. Make sure fire- FOR YOUR SAFETY minute for system to reset before place screen is installed befo

Summary of the content on the page No. 15

OWNER’S MANUAL Manually-Controlled Models LIGHTING OPERATING INSTRUCTIONS FIREPLACE FOR YOUR SAFETY Continued READ BEFORE WARNING: You must operate LIGHTING this fireplace with the fireplace TO TURN OFF GAS screen in place. Make sure fire- TO APPLIANCE place screen is installed before WARNING: If you do not fol- running fireplace. low these instructions exactly, a Shutting Off Fireplace fire or explosion may result caus- Turn control knob clockwise Clockwise to ing property damage, personal NO

Summary of the content on the page No. 16

® UNVENTED PROPANE/LP GAS FIREPLACE BLOWER OPERATING VARIABLE CONTROL OPERATION OPERATION FIREPLACE MODEL VSGF28PTC The variable control valve can be set to any Continued heat setting and flame height desired, by 6. Continue pressing control knob in. simply turning the control knob until that WARNING: This fireplace has Press and release ignitor button. This setting is attained. Even the lowest setting a three-prong, grounded electri- will light pilot. The pilot is attached to provides realisti

Summary of the content on the page No. 17

OWNER’S MANUAL FRONT BURNER FLAME OPERATING INSPECTING PATTERN FIREPLACE BURNERS Figure 34 shows correct front burner flame Continued Check pilot flame pattern and burner flame pattern. Figure 35 shows incorrect front patterns often. burner flame pattern. The incorrect burner Blower Kit Model GA3650T flame pattern shows yellow tipping at top of Series PILOT FLAME PATTERN blue flame. Locate the blower switch by opening the Figure 32 shows a correct pilot flame pat- lower louver on fireplace. Blow

Summary of the content on the page No. 18

® UNVENTED PROPANE/LP GAS FIREPLACE 4. Check the injector holder located at the LOGS CLEANING AND end of the burner tube again. Remove • If you remove logs for cleaning, refer to MAINTENANCE any large particles of dust, dirt, lint, or Installing Logs, page 13, to properly re- pet hair with a soft cloth or vacuum place logs. cleaner nozzle. WARNING: Turn off fireplace • Replace log(s) if broken or chipped and let cool before cleaning. 5. Blow air into the primary air holes on (dime-sized or larg

Summary of the content on the page No. 19

OWNER’S MANUAL TROUBLESHOOTING CAUTION: Never use a wire, WARNING: Turn off fireplace needle, or similar object to clean and let cool before servicing. Only Note: For additional help, visit DESA ODS/pilot. This can damage ODS/ a qualified service person should International’s technical service web site pilot unit. service and repair fireplace. at www.desatech.com. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pre

Summary of the content on the page No. 20

® UNVENTED PROPANE/LP GAS FIREPLACE TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY One or both burners do not light after ODS/ 1. Burner orifice(s) clogged 1. Clean burner(s) (see Cleaning and Main- pilot is lit tenance, page 18) or replace burner orifice(s) 2. Burner orifice(s) diameter is too small 2. Replace burner orifice(s) 3. Inlet gas pressure is too low 3. Contact local propane/LP gas company 4. Mislocated crossover tube 4. Contact qualified service person Delayed ignit


Alternative user manuals
# User manual Category Download
1 Vanguard Heating LogMate FB32NCA User manual Indoor Fireplace 0
2 Vanguard Heating SBVBN(A) User manual Indoor Fireplace 0
3 Vanguard Heating NLFB32C User manual Indoor Fireplace 0
4 Vanguard Heating NLFB32NC User manual Indoor Fireplace 0
5 Vanguard Heating 18" User manual Indoor Fireplace 0
6 Vanguard Heating SBVBP(A) User manual Indoor Fireplace 0
7 Vanguard Heating VDVF36PP User manual Indoor Fireplace 0
8 Vanguard Heating VDDVF36STN/STP User manual Indoor Fireplace 0
9 Vanguard Heating VDVF36PN User manual Indoor Fireplace 0
10 Vanguard Heating FB32CA User manual Indoor Fireplace 0
11 Vanguard Heating VDDVF36PN/PP User manual Indoor Fireplace 0
12 Vanguard Heating VDVF36STP User manual Indoor Fireplace 0
13 Vanguard Heating VMH26TN User manual Indoor Fireplace 0
14 Vanguard Heating VMH10TN User manual Indoor Fireplace 1
15 Vanguard Heating VMH10TNA User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1