Vanguard Heating 18" user manual

User manual for the device Vanguard Heating 18"

Device: Vanguard Heating 18"
Category: Indoor Fireplace
Manufacturer: Vanguard Heating
Size: 0.59 MB
Added : 12/16/2013
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Vanguard Heating 18". Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Vanguard Heating 18".

For your convenience

If looking through the Vanguard Heating 18" user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Vanguard Heating 18" on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Vanguard Heating 18" to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Vanguard Heating 18" User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Vanguard Heating 18" but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Vanguard Heating 18". If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

L
I
P
F
F
O
HI
LO
®
UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
Variable Manually-Controlled Models Also
Design-Certified As Vented Decorative Appliances
OWNER’S OPERATION AND INSTALLATION MANUAL
®
FLAME-MAX
Golden Oak Log
Design
®
18", 24", 30", and 36"
Remote Ready Model
Patent Pending
WARNING: Improper installation, ad-
WARNING: If the information in this
justment, alteration, service, or mainte-
manual is not followed exactly, a fire or
nance can cause injury or property dam-
explosion ma

Summary of the content on the page No. 2

® VANGUARD FLAME-MAX UNVENTED PROPANE/LP GAS LOG HEATER • do not try to light any appliance these products may create a white pow- SAFETY • do not touch any electrical switch; do der residue within burner box or on not use any phone in your building INFORMATION adjacent walls or furniture. • immediately call your gas supplier 14. Do not use a blower insert, heat ex- from a neighbor’s phone. Follow the changer insert or other accessory not WARNINGS WARNING ICON G 001 gas supplier’s instructions

Summary of the content on the page No. 3

HI TEMP MAN LO ON AUTO OFF STATUS OWNER’S MANUAL PRODUCT PRODUCT IDENTIFICATION FEATURES ® Flame-Max OPERATION Golden Oak Logs This heater is clean burning. It requires no outside venting. There is no heat loss out a One Piece vent or up a chimney. Heat is generated by Log Set realistic, dancing yellow flames. This heater is designed for vent-free operation with flue damper closed. It has been tested and ap- proved to ANS Z21.11.2 standard for unvented heaters. State and local codes in Optional

Summary of the content on the page No. 4

® VANGUARD FLAME-MAX UNVENTED PROPANE/LP GAS LOG HEATER Confined and Unconfined Space PROVIDING ADEQUATE AIR FOR VENTILATION The National Fuel Gas Code (ANS Z223.1, COMBUSTION AND 1992 Section 5.3) defines a confined space The following are excerpts from National VENTILATION as a space whose volume is less than 50 Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- 3 cubic feet per 1,000 Btu per hour (4.8 m per tion 5.3, Air for Combustion and Ventilation. WARNING: This heater shall kw) of the aggregate in

Summary of the content on the page No. 5

OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = _____________ cu. ft

Summary of the content on the page No. 6

® VANGUARD FLAME-MAX UNVENTED PROPANE/LP GAS LOG HEATER AIR FOR 12" COMBUSTION AND VENTILATION Ventilation Continued Ventilation Grills Grills Into Adjoining Room, Into Adjoining VENTILATION AIR Or Option 2 Room, Remove Ventilation Air From Inside Option 1 Door into Building Adjoining This fresh air would come from an adjoining Room, unconfined space. When ventilating to an Option adjoining unconfined space, you must pro- 3 vide two permanent openings: one within 12" of the ceiling and one wi

Summary of the content on the page No. 7

OWNER’S MANUAL INSTALLATION AND INSTALLATION WARNING: Never install the CLEARANCES heater NOTICE: This heater is intended (Vent-Free Operation Only) • in a bedroom or bathroom un- for use as supplemental heat. Use less installed as a vented ap- this heater along with your pri- WARNING: Maintain the mini- pliance, see page 10 mary heating system. Do not in- mum clearances. If you can, pro- • in a recreational vehicle stall this heater as your primary vide greater clearances from • where curtains

Summary of the content on the page No. 8

® VANGUARD FLAME-MAX UNVENTED PROPANE/LP GAS LOG HEATER INSTALLATION Noncombustible Requirements for Continued Material Distance (A) Safe Installation 12" or more Noncombustible material OK. NOTICE: Manual control heaters Between 8" and 12" 24", 30", or 36" Models: Install fireplace hood ac- may be used as a vented product. cessory (GA6050, GA6052 or GA6053 see Acces- If so, you must always run heater sories, page 24). with chimney flue damper open. If 18" Model: Noncombustible material OK. runn

Summary of the content on the page No. 9

OWNER’S MANUAL Mantel Shelf 10" INSTALLATION Underside of 8" Continued Mantel Shelf 6" 1 2 /2" MANTEL CLEARANCES In addition to meeting noncombustible mate- All minimum rial clearances, you must also meet required distances are clearances between fireplace opening and in inches Minimum Non- mantel shelf. If you do not meet the clear- (A) Combustible ances listed below, you will need a hood. Log Set Material 12" 18" 20" 22" 24" 24"/30"/36" Models Determining Minimum Mantel 3 8" 8" 14" 16 /4" 2

Summary of the content on the page No. 10

® VANGUARD FLAME-MAX UNVENTED PROPANE/LP GAS LOG HEATER INSTALLATION Continued Damper INSTALLING DAMPER Clamp Damper CLAMP ACCESSORY FOR VENTED OPERATION Damper Note: When used as a vented heater, appli- Clamp ance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material. If your heater is a manually controlled model, you may use this heater as a vented product. Damper Damper There are three reasons for operating your heater in the v

Summary of the content on the page No. 11

OWNER’S MANUAL CONNECTING TO GAS INSTALLATION CAUTION: Use only new, SUPPLY Continued black iron or steel pipe. Inter- nally-tinned copper tubing may NOTICE: A qualified service per- 5. Center heater base and logs front-to- be used in certain areas. Check son must connect heater to gas back and side-to-side in fireplace. your local codes. Use pipe of 1/2" supply. Follow all local codes. 6. Carefully remove logs without moving diameter or greater to allow heater base. proper gas volume to heater

Summary of the content on the page No. 12

® VANGUARD FLAME-MAX UNVENTED PROPANE/LP GAS LOG HEATER Pressure Testing Heater Gas INSTALLATION Connections Continued A.G.A. Design-Certified Manual 1. Open manual shutoff valve (see Fig- Shutoff Valve With 1/8" NPT Tap* ure 15). 2. Open propane supply tank valve. From External Regulator (11" Approved Flexible 3. Make sure control knob of heater is in Gas Hose (if allowed W.C.** to 14" the OFF position. W.C. Pressure) by local codes) 4. Check all joints from manual shutoff valve to control valv

Summary of the content on the page No. 13

OWNER’S MANUAL One Piece Log Set INSTALLATION Continued INSTALLING LOGS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property Middle damage or personal injury. Section at Bottom of Log Set CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re- B

Summary of the content on the page No. 14

O L I P F F O H I L ® VANGUARD FLAME-MAX UNVENTED PROPANE/LP GAS LOG HEATER LIGHTING OPERATING WARNING: Burner will come INSTRUCTIONS on automatically within one HEATER minute when the selector switch FOR YOUR SAFETY WARNING: is in the ON position after the READ BEFORE • If fireplace has glass doors, pilot is lit. never operate this heater with LIGHTING 4. Press in and turn control knob clock- glass doors closed. If you op- wise to the OFF position. erate heater with doors closed, WARNING:

Summary of the content on the page No. 15

OWNER’S MANUAL For wall thermostat operation, follow in- TO TURN OFF GAS OPERATING structions supplied with thermostat acces- TO APPLIANCE HEATER sory GWMT1. For wall switch operation Shutting Off Heater follow instruction supplied with GWMS2. Continued 1. Turn control knob clockwise NOTICE: You must light the pilot 8. Keep control knob pressed in for 30 to the OFF position. before using the hand-held re- seconds after lighting pilot. After 30 2a. Set selector switch in the OFF position mote c

Summary of the content on the page No. 16

N O T O H L I I L ® VANGUARD FLAME-MAX UNVENTED PROPANE/LP GAS LOG HEATER 3. Use the STATUS button on the hand- OPERATING INSPECTING held remote control unit to see the operation mode being used and the HEATER BURNERS temperature setting selected. A red Continued Check pilot flame pattern and burner flame light will come on beside the opera- patterns often. tion mode being used when the sta- IMPORTANT: This remote control tus button is pressed. has been specially engineered to PILOT FLAME PATTER

Summary of the content on the page No. 17

OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater CAUTION: Never use a wire, and let cool before servicing. needle, or similar object to clean Note: For additional help, visit DESA ODS/pilot. This can damage ODS/ Only a qualified service person International’s technical service web site should service and repair pilot unit. at www.desatech.com. heater. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed,

Summary of the content on the page No. 18

® VANGUARD FLAME-MAX UNVENTED PROPANE/LP GAS LOG HEATER TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does not light after ODS/pilot is lit 1. Burner orifice clogged 1. Clean burner (see Cleaning and Main- tenance, page 21) or replace burner orifice 2. Inlet gas pressure is too low 2. Contact local propane gas company 3. Burner orifice diameter is too small 3. Replace burner orifice 4. Thermopile leads disconnected or im- 4. Reconnect leads (see Wiring Diagram, properly

Summary of the content on the page No. 19

OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette

Summary of the content on the page No. 20

AUTO ON OFF ® VANGUARD FLAME-MAX UNVENTED PROPANE/LP GAS LOG HEATER WIRING DIAGRAM REPLACEMENT PARTS Note: For proper operation of optional ac- cessories, the wires from the switch to the Note: Use only original replacement parts. control must be connected exactly as shown. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni-


Alternative user manuals
# User manual Category Download
1 Vanguard Heating LogMate FB32NCA User manual Indoor Fireplace 0
2 Vanguard Heating SBVBN(A) User manual Indoor Fireplace 0
3 Vanguard Heating NLFB32C User manual Indoor Fireplace 0
4 Vanguard Heating NLFB32NC User manual Indoor Fireplace 0
5 Vanguard Heating SBVBP(A) User manual Indoor Fireplace 0
6 Vanguard Heating VDVF36PP User manual Indoor Fireplace 0
7 Vanguard Heating VDDVF36STN/STP User manual Indoor Fireplace 0
8 Vanguard Heating VDVF36PN User manual Indoor Fireplace 0
9 Vanguard Heating FB32CA User manual Indoor Fireplace 0
10 Vanguard Heating VDDVF36PN/PP User manual Indoor Fireplace 0
11 Vanguard Heating VDVF36STP User manual Indoor Fireplace 0
12 Vanguard Heating VMH26TN User manual Indoor Fireplace 0
13 Vanguard Heating VMH10TN User manual Indoor Fireplace 1
14 Vanguard Heating VMH10TNA User manual Indoor Fireplace 0
15 Vanguard Heating VMH26NR User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1