Superior VF4000-CHN-2 user manual

User manual for the device Superior VF4000-CHN-2

Device: Superior VF4000-CHN-2
Category: Indoor Fireplace
Manufacturer: Superior
Size: 1.06 MB
Added : 3/30/2013
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Superior VF4000-CHN-2. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Superior VF4000-CHN-2.

For your convenience

If looking through the Superior VF4000-CHN-2 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Superior VF4000-CHN-2 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Superior VF4000-CHN-2 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Superior VF4000-CHN-2 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Superior VF4000-CHN-2 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Superior VF4000-CHN-2. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION AND
OPERA TION INSTRUCTIONS
STANDARD SERIES
Unvented Decorative Gas Fireplaces
P/N 903590, REV . P , 04/2010
MODELS
VF4000-CHN-2 VF4000-CHP-2
VF4000-CMN-2 VF4000-CMP-2

FOR USE ONL Y WITH DECORA TIVE TYPE
UNVENTED ROOM HEA TERS.
DO NOT BUILD A WOOD FIRE.
W ARNING: IMPROPER INST ALLA TION, ADJUSTMENT ,
AL TERA TION, SERVICE OR MAINTENANCE CAN CAUSE
Portland
INJUR Y OR PROPER TY DAMAGE. REFER TO THIS MANUAL.
US FOR ASSIST ANCE OR ADDITIONAL INFORMA TION CONSUL T
A QUALIFIED IN

Summary of the content on the page No. 2

These heaters are manually controlled. Models Tee joint TABLE OF CONTENTS VF4000-CMN-2 and VF4000-CMP-2 feature a Pipe compound gas valve incorporating a millivolt operating General Information ......................... page 2 system. Building Supplies Should Include: Inventory ......................................... page 2 Tools and Building Supplies ............ page 2 A spark ignition system (piezo) allows the heater Framing materials pilot gas to be lit without the use of matches or Wall

Summary of the content on the page No. 3

• The heater must be isolated from the gas • Vent-Free appliances may NOT be installed in WARNING: FAILURE TO COMPLY WITH supply piping system by closing its individual bedrooms or bathrooms. THE INSTALLATION AND OPERATING manual shut-off valve during any pressure test- INSTRUCTIONS PROVIDED IN THIS • A working smoke detector must be installed ing of the gas supply piping system at test DOCUMENT WILL RESULT IN AN IM- pressures equal to or less than 1/2 psig. in the area where vent-free applianc

Summary of the content on the page No. 4

Use the following equations to determine if you • This appliance may be installed in an after- WARNING: IF THE AREA IN WHICH THE have a confined or unconfined space. market* manufactured (Mobile) Home, where HEATER MAY BE OPERATED IS SMALLER not prohibited by state or local codes. 3 THAN THAT DEFINED AS AN UNCON- 1. Determine the volume of space — ft . *Aftermarket: Completion of sale, not for pur- pose of resale, from the manufacturer. FINED SPACE, PROVIDE ADEQUATE 3 Length x Width x Height =

Summary of the content on the page No. 5

Do not install in the vicinity of gasoline or other Note: Combustible wall finish materials and/or Note: The following steps represent the normal flammable liquids. The heater must be kept surround materials must not be allowed to sequence of installation. Each installation is clear and free from these combustible materi- encroach the area defined by the appliance unique, however, and might require a different als and may not be located near where they are front face (black sheet metal). Never a

Summary of the content on the page No. 6

Back Wall of Chase/Enclosure Including Finishing Outside Wall Materials If Any. 15-1/2" (394mm) Control Valve (Standard) 37" (940mm) Lower Control Compartment Door Figure 4 Back Wall of 3" 7" Chase/Enclosure (76 mm) Including Finishing (178 mm) Figure 9 Materials If Any. 41" Secure all joints tightly using appropriate (1041mm) 13-1/2" tools and sealing compounds (ensure pro- Figure 7 (343mm) pane resistant compounds are used in 29" (737mm) propane applications). The gas control valve is located

Summary of the content on the page No. 7

A. Light the appliance (refer to safety and Step 6. Installing the Optional Forced Air VF4000-CMN/P Series lighting instructions on pages 14 and 16). Blower Kit Wiring – A receptacle plate is Optional Wiring Diagram provided for the installation of the FAB-1100 If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. B. Brush all joints and connections with the forced air blower kit (optional). Electrical From Thermocouple gas leak test so

Summary of the content on the page No. 8

IMPORTANT: Ground lead must be connected Assembling the Logs to the green screw located on the junction box cover plate. Failure to do so will prevent the WARNING: DO NOT ADD EXTRA LOGS OR appliance from operating. ORNAMENTS SUCH AS PINE CONES, VER- MICULITE OR ROCK WOOL. USING THESE The appliance must be electrically grounded in ADDED ITEMS CAN CAUSE SOOTING. accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70-(latest edition). (In Canada, t

Summary of the content on the page No. 9

After setting the logs into position as described Step 13. Checking the System – With gas line above, ensure they are properly and firmly installed run initial system checkout before situated. The heater will not function as in- closing up the front of the unit. Follow the pilot tended if the logs are not correctly positioned. lighting instructions on pages 14 and 16. Periodically check the positioning of the logs. Note: Instructions are also found on the pull out panel located on the bottom s

Summary of the content on the page No. 10

OPTIONAL EQUIPMENT Decorative Volcanic Stone Blower Motor An incomparable package of options are avail- The decorative volcanic stone, Model FDVS, able for use with these appliances. These op- can be used to enhance the look of your tions can both customize the operation of these appliance. Spread the decorative volcanic stone Grounded unique appliances and enhance their beauty evenly around the bottom of the firebox. to Appliance and charming appeal. All options are available in kit form, are e

Summary of the content on the page No. 11

Remote Control Kit OPERATION AND CARE OF YOUR CLEANING AND SERVICING APPLIANCE The Model RCL adds the convenience of re- WARNING: TURN OFF THE UNVENTED mote control for your millivolt controlled ap- 1. Blower operation may be controlled through GAS ROOM HEATER AND ALLOW TO COOL pliance. The kit includes a wireless, hand held the ON/OFF unit rocker switch, located in the BEFORE CLEANING. transmitter and a receiver that replaces the lower control compartment. wall switch. This special receiver per

Summary of the content on the page No. 12

ACCESSORIES AND COMPONENTS Forced Air Kit FAB-1100 Brass Louver Kit BRLK-5C Wall Switch Kit FWSK Wood Surround-Wall SUR-5PW Rocker Switch Kit FRS Refractory Liner Kit VF5RLK Remote Control RCL Wood Surround-Corner SUR-5PC Gas Flex Line Kit FFGC Thermostat WTK BSK-5 Brass Surround Kit BRLK-CS Square Trim Kit STK-5-4 Decorative Volcanic Stone FDVS 12 NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

Summary of the content on the page No. 13

VF4000 SPECIFICATIONS 37" (940 mm) 31-1/2" 15" (800 mm) (381 mm) 30" (762 mm) 36" (914 mm) Front View 5-1/2" (140 mm) 1/2" (13 mm) 37" (940 mm) 31-1/2" (800 mm) 3-3/4" (95 mm) 8" (203 mm) J Box Gas Line Opening Opening 3-1/2" 3" (76 mm) (89 mm) 15-1/2" (394 mm) Left Side View (Right Side View - Opposite) 27" (686 mm) 15-1/2" (394 mm) 36" (914 mm) Top View Figure 21 NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13

Summary of the content on the page No. 14

VF4000-CHM/P OPERATING INSTRUCTIONS (STANDARD VALVES) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This heater has a pilot which must be lit by hand. When • Immediately call your gas supplier from a neighbor’s lighting the pilot, follow these instructions exactly. phone. Follow the gas supplier’s instructions. B. BEFORE OPERATING smell all around the heate

Summary of the content on the page No. 15

H I I G N L O W I G N O F F O F F Turn Control Knob to “OFF” Position Turn Control Knob to “IGN” Position Figure 24 Figure 22 Pilot Pilot Location Figure 23 NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 H I L O W

Summary of the content on the page No. 16

T O O O L I P O N O L T N VF4000-CMN/P OPERATING INSTRUCTIONS (MILLIVOLT VALVES) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted by hand. • Do not use any phone in your building. When lighting the pilot, follow these instructions exactly. • Immediately call your gas supplier from a neighbor’s phone. • If your

Summary of the content on the page No. 17

TROUBLESHOOTING GUIDE FOR UNVENTED GAS PRODUCTS OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1. When igniter button is A. Igniter electrode positioned wrong. Replace igniter. pressed, there is no spark at ODS/pilot. B. Igniter electrode broken. Replace igniter. C. Igniter electrode not connected to igniter cable. Reconnect igniter cable. D. Igniter cable pinched or wet. Free igniter cable if pinched by any metal or tubing. Keep igniter cable dry. E. Piezo igniter nut is loose. Tighten nut. F. Broken i

Summary of the content on the page No. 18

R E P L A C E M E N T P A R T S L I S T V F 4 0 0 0 - C H N ( M a n u a l ) V F 4 0 0 0 - C M N ( M i l l i v o l t ) I t e m V F 4 0 0 0 - C H P ( M a n u a l ) V F 4 0 0 0 - C M P ( M i l l i v o l t ) D e s c r i p t i o n N o . P a r t N o . Q t y . P a r t N o . Q t y . 1 . Valve (Natural) H4111 1 – – Valve (Propane) H4111 1 – – SIT Valve (Natural) – – H4173 1 Honeywell Valve (Natural) – – 24M13 1 SIT Valve (Propane) – – H4278 1 Honeywell Valve (Propane) – – 67L02

Summary of the content on the page No. 19

REPLACEMENT PARTS 13 11 14 12 15 CM Models (SIT Valve Shown) CH Models 8 1 12 13 CH Models 2 3 4 CM Models 7 10 6 9 5 NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19

Summary of the content on the page No. 20

Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications and prices, and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. LHP Printed in U.S.A. © 1997 by Lennox Hearth Products 1508 Elm Hill Pike, Suite 108 P/N 903590 REV. P 04/2010 Nashville, TN 37210 20 NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.


Alternative user manuals
# User manual Category Download
1 Superior 36" B-VENTED GAS APPLIANCES B-40REP User manual Indoor Fireplace 2
2 Superior 36" B-VENTED GAS APPLIANCES B-40RMP User manual Indoor Fireplace 1
3 Superior 600 User manual Indoor Fireplace 5
4 Superior 36" B-VENTED GAS APPLIANCES B-40RMN User manual Indoor Fireplace 1
5 Superior ARCHED FACE KITS SDVI User manual Indoor Fireplace 1
6 Superior 800 User manual Indoor Fireplace 3
7 Superior BC-36-2 User manual Indoor Fireplace 2
8 Superior BR-36-2 User manual Indoor Fireplace 9
9 Superior BC-36 User manual Indoor Fireplace 67
10 Superior br-36 User manual Indoor Fireplace 3
11 Superior BCD36MH User manual Indoor Fireplace 10
12 Superior BC36MH User manual Indoor Fireplace 2
13 Superior BCI-36 User manual Indoor Fireplace 1
14 Superior 500 User manual Indoor Fireplace 2
15 Superior CDCL-CEN User manual Indoor Fireplace 1
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1