Superior SLBV-40PM user manual

User manual for the device Superior SLBV-40PM

Device: Superior SLBV-40PM
Category: Indoor Fireplace
Manufacturer: Superior
Size: 3.04 MB
Added : 11/13/2013
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Superior SLBV-40PM. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Superior SLBV-40PM.

For your convenience

If looking through the Superior SLBV-40PM user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Superior SLBV-40PM on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Superior SLBV-40PM to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Superior SLBV-40PM User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Superior SLBV-40PM but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Superior SLBV-40PM. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION INSTRUCTIONS
B-Vent Gas Fireplaces
SLBV 35/40 Models
P/N 506009-02 Rev. B 06/2011
This manual is one of a set of two supporting this product.
MODELS
Refer to P/N 506010-02 for Care and Operation Instructions.
MILLIVOLT: ELECTRONIC:
Ce manuel est disponible en francais, simplement
SLBV-35NM SLBV-40NM SLBV-35NE
en faire la demande. Numéro de la pièce 506223-19.
SLBV-35PM SLBV-40PM SLBV-40NE
ITS Report No. 100017854
INSTALLER: Leave this manual with the appliance.
CONSUMER: R

Summary of the content on the page No. 2

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS TABLE Of CONTENTS PACKAGING WARNING Packaging .........................................Page 2 The assembled vented gas fireplace is packaged with the following items: Introduction ......................................Page 2 Young children should be care- fully supervised when they are General Information ..........................Page 2 1 - One log set located in firebox area. 2 - One envelope

Summary of the content on the page No. 3

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Installation must conform to local codes, or, in GENERAL INf ORMATION the absence of local codes, with the National (continued) Fuel Gas Code, ANSI Z223.1/NFPA 54 (latest edition), or the Natural Gas and Propane Instal- WARNING lation Code, CAN/CSA B149.1 (latest edition). Improper installation, adjust- The appliance, when installed, must be electri- ment, alteration, service or cally groun

Summary of the content on the page No. 4

O W OUT IN IN T H N ® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS ORIfICE SIzES GAS VALVE dIAGRAMS GAS PRESSURE REqUIREMENTS Sea Level to High Altitude (All Models) See Figure 1 for millivolt models and Figure 2 (All Models) for electronic models. Tables 2 and 3 show the appliances' inlet and manifold gas pressure requirements: These appliances are tested and approved for Pilot Adjustment installation at elevations of 0–4500 feet (0–1372 Main Ga

Summary of the content on the page No. 5

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Combustion air kits are optional and must be COLd CLIMATE INSULATION LOCATION installed before removing the securing screw allowing the movement of the combustion air For cold climate installations, seal all cracks In selecting the location, the aesthetic and actuator arm (see Step 5 on Page 14). functional use of the appliance are primary around your appliance with noncombustible material and wherev

Summary of the content on the page No. 6

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS VENT TERMINATION Termination Heights for Vents Gas Vent Rule Above flat Or Sloped Roofs CLEARANCES Ref. NfPA 54 / ANSI z223.1 Roof Pitch * f eet * Meters Multiple Terminations Flat to 6/12 1.0 0.3 These appliances may vent adjacent to and at X the same level with any other gas appliances 6/12 to 7/12 1.25 0.38 12 (including direct vent appliances), provided Roof Pitch is X/12 7/12 to 8/12 1.5 0.46 th

Summary of the content on the page No. 7

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS MINIMUM CLEARANCES TO COMBUSTIBLES At 14" minimum side At 8-1/4" side Appliance and Vent Clearances wall clearance, a wall clearance, a Top View of combustible wall can combustible wall f ireplace project to any length. can project 12". The appliance is approved with zero clearance to combustible materials on all sides (as detailed in Table 6), with the following exception: When the unit is installed

Summary of the content on the page No. 8

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Step 5. (Page 14) [OPTIONAL]: Install PRE-INSTALLATION STEPS outside supplemental combustion Header (Remove Glass Enclosure Panel) Top air kit. Spacing Standoff Top The appliance is shipped with all gas controls Spacers* Standoffs Step 6. (Page 15) Make connection to gas and components installed and pre-wired. supply. *IMPORTANT! Note: Remove the glass enclosure panel 5/8" Bend up the 5/8” befor

Summary of the content on the page No. 9

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS f IREPLACE ANd f RAMING SPECIf ICATIONS f IREPLACE f RAMING SPECIf ICATIONS NOTE: Diagrams, illustrations and Construct framing with 2x4 or larger lumber. photographs are not to scale. Product designs, materials, dimensions, specifications, colors, and prices are subject to change or discontinuance without notice. Input (BTU/HR) - MV & Electronic Natural & Propane Gas B Models Input Rate (BTU/hr)

Summary of the content on the page No. 10

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS VERTICAL VENTING THROUGH CEILING frame Ceiling Opening: To locate the center of the vertical run, use a plumb line from the ceiling above the appliance. M N P Flue Outlet for B-Vent Connection: H K 35 Models = 4 in. (102 mm) J L 40 Models = 5 in. (127 mm) 1/2 in. (13 mm) M 9-1/4 in. (235 mm) Q N Top View Front View P Flue Outlet for B-Vent Connection: H K 35 Models = 4 in. (102 mm) J H J K L M N P Q Mo

Summary of the content on the page No. 11

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Note: Step 2. Route the Gas Line WARNING • All appliances are factory-equipped with Route a 1/2" (13 mm) gas line to either side a flexible gas line connector and 1/2 inch of the appliance (left side routing is shown shutoff valve (see Figure 17 on Page 15). Sharp Edges. in Figure 9 ). Gas lines must be routed, con- • See Massachusetts Requirements on Page structed, and made of materials that

Summary of the content on the page No. 12

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS ON/OFF switch, the switch may be mounted onto the Style View Door per instructions provided in kit. • The gas valve is set in place and pre-wired at Offset Installations the factory on all models. Vertical Installations Refer to Section B (below) for millivolt appli- ances and Section C (below) for electronic appliances. 10 ft. *12 ft. Min. 10 ft. *12 ft. Min. Minimum **15 ft. Min. Minimum **15 ft

Summary of the content on the page No. 13

I O O L I P T O it VENT TH TH TP TP TPTH TP TH L I P F L F O ® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS J-BOX/RECEPTACLE WIRING MILLIVOLT WIRING dIAGRAM J-BOX / RECEPTACLE WIRING 120V, 60Hz, 1PH 120V, 60HZ, 1PH CAUTION: WHEN SERVICING CONTROLS, LABEL ALL WIRES PRIOR TO dISCONNECTION. WIRING ERRORS CAN CAUSE IMPROPER ANd dANGEROUS OPERATION. VERIf Y PROPER OPERATION Af TER SERVICING. B-VENT APPLIANCES ONLY: The High Limit Thermopile Switch must

Summary of the content on the page No. 14

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Failure to do so may result in extensive and Step 5. [OPTIONAL] Install Outside INSTALLATION ACCESSORIES costly rework. Before the operation of the vent Combustion Air Kit system can be tested, the lever securing screw The following accessory items are available for must be removed. See Figure 15. An optional outside combustion air kit (model use in the installation of this appliance. FOAK-4, FOAK-4LD

Summary of the content on the page No. 15

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Step 6. Connect the Gas Line Gas Flex Line Connector All codes require a shut-off valve mounted in 3/8" NPT x Gas 1/2" x 3/8" Flare the supply line. The orientation of the shut- Flare Fitting Valve Shut-off Valve off valve should face the front. Figure 16 illustrates two methods for connecting the gas Note: The gas supply supply. A sediment trap is recommended in the line must be installed in

Summary of the content on the page No. 16

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Test All Connections for Gas Leaks Millivolt Appliance Checkout Step 7. Verify Appliance (factory and field) Operation The pilot flame should be steady, not lifting or floating. Flame should be blue in color with Turn on burner then observe the individual traces of orange at the outer edge. WARNING tongues of flame on the burner. Make sure all ports are open and producing flame evenly The top

Summary of the content on the page No. 17

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS 4. Place the glowing ember material 5. Install the Logs. Step 8. Install Volcanic Stone, (rockwool). Glowing Embers (Rockwool), The logs have locating notches or slots to Note: The bag of Glowing Embers and Logs help ensure that they are properly positioned. contains enough rockwool for several The top logs that rest on lower logs, do so NOTE: Turn OFF all electricity to the fire- applications; t

Summary of the content on the page No. 18

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS SLBV-35 LOG PLACEMENT INSTRUCTIONS Note: 3 Left Rear Log Right Rear Log 4 • Ceramic fiber logs are FRAGILE! Handle carefully to prevent breakage. • Install volcanic stone and glowing embers BEFORE installing logs. • To prevent sooting, make sure logs do not cover any burner openings. SLBV firebox Accessories/Parts Cat. No. Model No. description H7244 — SLBV-35 Log Set Assembly 88L53 fGE Bag of Glowin

Summary of the content on the page No. 19

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS SLBV-40 LOG PLACEMENT INSTRUCTIONS Note: Ember Chunk 1 • Ceramic fiber logs are FRAGILE! Handle carefully to prevent breakage. 4 Left Rear Log 5 Right Rear Log • Install volcanic stone and glowing embers BEFORE installing logs. • To prevent sooting, make sure logs do not cover any burner openings. SLBV firebox Accessories/Parts Cat. No. Model No. description H7245 — SLBV-40 Log Set Assembly 88L53 fGE

Summary of the content on the page No. 20

® SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS 3. Install the hood. Note the location of the Step 9. Install the Glass Enclosure Step 10. Burner Air Shutter three clips inside the top air channel above Panel Adjustments the glass enclosure panel. The clips are (qUALIfIEd TECHNICIANS ONLY) equally spaced on the top surface of the air channel opening. If needed, use a screw- WARNING Flame Appearance and Sooting driver to open the clips


Alternative user manuals
# User manual Category Download
1 Superior 36" B-VENTED GAS APPLIANCES B-40REP User manual Indoor Fireplace 2
2 Superior 36" B-VENTED GAS APPLIANCES B-40RMP User manual Indoor Fireplace 1
3 Superior 600 User manual Indoor Fireplace 5
4 Superior 36" B-VENTED GAS APPLIANCES B-40RMN User manual Indoor Fireplace 1
5 Superior ARCHED FACE KITS SDVI User manual Indoor Fireplace 1
6 Superior 800 User manual Indoor Fireplace 3
7 Superior BC-36-2 User manual Indoor Fireplace 2
8 Superior BR-36-2 User manual Indoor Fireplace 9
9 Superior BC-36 User manual Indoor Fireplace 67
10 Superior br-36 User manual Indoor Fireplace 3
11 Superior BCD36MH User manual Indoor Fireplace 10
12 Superior BC36MH User manual Indoor Fireplace 2
13 Superior BCI-36 User manual Indoor Fireplace 1
14 Superior 500 User manual Indoor Fireplace 2
15 Superior CDCL-CEN User manual Indoor Fireplace 1
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1